The detection of Pseudomonas aeruginosa using the quartz crystal microbalance

被引:3
|
作者
Bovenizer, JS [1 ]
Jacobs, MB [1 ]
O'Sullivan, CK [1 ]
Guilbault, GG [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Chem, Lab Sensor Dev, Cork, Ireland
关键词
Pseudomonas aeruginosa; QCM; PZ immunosensor; milk; dairy;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a piezoelectric immunosensor for the detection of Pseudomonas aeruginosa in milk and dairy samples was undertaken here. This was achieved primarily by optimising the system using. ELISA, investigating capture, competitive and displacement assays. Results from ELISA supplied information on detection limits and linear ranges obtained with each assay. A displacement assay was chosen to be transferred to the piezoelectric system and the reduction in mass on the surface of the crystal due to antigen displacement was measured by recording the frequency changes of the quartz crystal microbalance. The linear range obtained was from 2x10(6) cell/ml to 1x10(8) cell/ml and the limit of detection was 100,000 cells. The system was also tested for cross reactivity with a non-specific antigen, Pseudomonas fluorescens.
引用
收藏
页码:1287 / 1295
页数:9
相关论文
共 50 条
  • [41] Amplified detection of telomerase activity using electrochemical and quartz crystal microbalance measurements
    Pavlov, V
    Willner, I
    Dishon, A
    Kotler, M
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (05): : 1011 - 1021
  • [42] Conventional detection of 2,4-dinitrophenol using quartz crystal microbalance
    Park, JW
    Kurosawa, S
    Aizawa, H
    Han, DS
    Yoshimoto, M
    Nakamura, C
    Miyake, J
    Chang, SM
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (02) : 193 - 195
  • [43] Detection of 3-Carene in mango using a quartz crystal microbalance sensor
    Ali, Sk Babar
    Ghatak, Barnali
    Gupta, Sudipto Dutta
    Debabhuti, Nilava
    Chakraborty, Parthojit
    Sharma, Prolay
    Ghosh, Arunangshu
    Tudu, Bipan
    Mitra, Souvik
    Sarkar, Mousumi Poddar
    Bhattacharyya, Nabarun
    Bandyopadhyay, Rajib
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 230 : 791 - 800
  • [44] Using the quartz crystal microbalance principle for gas detection with reversible and irreversible sensors
    Hartmann, Jens
    Auge, Jorg
    Hauptmann, Peter
    Sensors and Actuators, B: Chemical, 1994, B19 (1 -3 pt 2) : 429 - 433
  • [45] Antibody Mimetics for the Detection of Small Organic Compounds Using a Quartz Crystal Microbalance
    Koutsoumpeli, Eleni
    Tiede, Christian
    Murray, James
    Tang, Anna
    Bon, Robin S.
    Tomlinson, Darren C.
    Johnson, Steven
    ANALYTICAL CHEMISTRY, 2017, 89 (05) : 3051 - 3058
  • [46] Detection of Salmonella Typhimurium with Gold Nanoparticles Using Quartz Crystal Microbalance Biosensor
    Min, Hyun Jung
    Mina, Hansel A.
    Deering, Amanda J.
    Robinson, J. Paul
    Bae, Euiwon
    SENSORS, 2022, 22 (22)
  • [47] Detection of vaccinia virus DNA by quartz crystal microbalance
    Kleo, K.
    Kapp, A.
    Ascher, L.
    Lisdat, F.
    ANALYTICAL BIOCHEMISTRY, 2011, 418 (02) : 260 - 266
  • [48] Acoustic detection of cell adhesion on a quartz crystal microbalance
    Da-Silva, Ana-Carina
    Rodrigues, Rogerio
    Rosa, Luis F. M.
    de-Carvalho, Jorge
    Tome, Brigitte
    Ferreira, Guilherme N. M.
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2012, 59 (06) : 411 - 419
  • [49] Humidity Tolerant Organic Vapor Detection Using a Superhydrophobic Quartz Crystal Microbalance
    Esmeryan, Karekin D.
    Yordanov, Tsvetan A.
    Vergov, Lazar G.
    Raicheva, Zdravka G.
    Radeva, Ekaterina I.
    IEEE SENSORS JOURNAL, 2015, 15 (11) : 6318 - 6325
  • [50] Detection of Methyl Salicylate in Black Tea Using a Quartz Crystal Microbalance Sensor
    Sharma, Prolay
    Tudu, Bipan
    Bhuyan, Lakshi Prasad
    Tamuly, Pradip
    Bhattacharyya, Nabarun
    Bandyopadhyay, Rajib
    IEEE SENSORS JOURNAL, 2016, 16 (13) : 5160 - 5166