Quantitative depth profiling of boron and arsenic ultra low energy implants by pulsed rf-GD-ToFMS

被引:18
|
作者
Lobo, Lara [1 ]
Fernandez, Beatriz [1 ]
Pereiro, Rosario [1 ]
Bordel, Nerea [2 ]
Demenev, Evgeny [3 ]
Giubertoni, Damiano [3 ]
Bersani, Massimo [3 ]
Hoenicke, Philipp [4 ]
Beckhoff, Burkhard [4 ]
Sanz-Medel, Alfredo [1 ]
机构
[1] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
[2] Univ Oviedo, Dept Phys, Fac Sci, Oviedo 33007, Spain
[3] Fdn Bruno Kessler, Ctr Mat & Microsyst Irst, MiNALab, I-38100 Trento, Italy
[4] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
OPTICAL-EMISSION-SPECTROMETRY; FLIGHT MASS-SPECTROMETER; X-RAY-FLUORESCENCE; GLOW-DISCHARGE; SYNCHROTRON-RADIATION; SILICON; SIMS; SPECTROSCOPY; GLASSES; FILMS;
D O I
10.1039/c0ja00197j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In very recent years particular effort is being devoted to the development of radiofrequency (rf) pulsed glow discharges (GDs) coupled to time of flight mass spectrometry (ToFMS) for depth profile qualitative analysis with nanometre depth resolution of technological materials. As such technique does not require sampling at ultra-high vacuum conditions it facilitates a comparatively high sample throughput, related to the reference technique secondary ion mass spectrometry (SIMS). In this work, pulsed rf-GD-ToFMS is investigated for the fast and sensitive characterization of boron and arsenic ultra low energy (ULE) implants on silicon. The possibility of using a simple multi-matrix calibration procedure is demonstrated for the first time for quantification of this type of samples and the validation of the proposed procedure has been carried out through the successful analysis of a multilayered sample with single and couple 11 B delta markers. Results obtained with the proposed methodology for boron and arsenic ULE implants, prepared under different ion doses and ion energy conditions, have proved to be in good agreement with those achieved by using complementary techniques including SIMS and grazing incidence X-ray fluorescence. Thus, although further investigations are necessary for more critical evaluation of depth resolution, the work carried out demonstrates that rf-GD-ToFMS can be an advantageous tool for the analytical characterization of boron and arsenic ULE implants on silicon.
引用
收藏
页码:542 / 549
页数:8
相关论文
共 35 条
  • [1] Pulsed rf-GD-TOFMS for depth profile analysis of ultrathin layers using the analyte prepeak region
    Pisonero, J.
    Valledor, R.
    Licciardello, A.
    Quiros, C.
    Martin, J. I.
    Sanz-Medel, A.
    Bordel, N.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (08) : 2437 - 2448
  • [2] Pulsed rf-GD-TOFMS for depth profile analysis of ultrathin layers using the analyte prepeak region
    J. Pisonero
    R. Valledor
    A. Licciardello
    C. Quirós
    J. I. Martín
    A. Sanz-Medel
    N. Bordel
    [J]. Analytical and Bioanalytical Chemistry, 2012, 403 : 2437 - 2448
  • [3] Boron ultra low energy SIMS depth profiling improved by rotating stage
    Bersani, M.
    Giubertoni, D.
    Iacob, E.
    Barozzi, M.
    Pederzoli, S.
    Vanzetti, L.
    Anderle, M.
    [J]. APPLIED SURFACE SCIENCE, 2006, 252 (19) : 7315 - 7317
  • [4] Ultra-shallow arsenic implant depth profiling using low-energy nitrogen beams
    Fearn, S
    Chater, R
    McPhail, D
    [J]. APPLIED SURFACE SCIENCE, 2004, 231 : 645 - 648
  • [5] Anomalous diffusion of ultra low energy boron implants in silicon
    Webb, RP
    Foad, MA
    Gwilliam, RM
    Knights, AP
    Thomas, G
    [J]. DEFECTS AND DIFFUSION IN SILICON PROCESSING, 1997, 469 : 59 - 63
  • [6] Combined Pulsed RF GD-OES and HAXPES for Quantified Depth Profiling through Coatings
    Bouttemy, Muriel
    Bechu, Solene
    Spencer, Ben F.
    Dally, Pia
    Chapon, Patrick
    Etcheberry, Arnaud
    [J]. COATINGS, 2021, 11 (06)
  • [7] Direct chemical in-depth profile analysis and thickness quantification of nanometer multilayers using pulsed-rf-GD-TOFMS
    R. Valledor
    J. Pisonero
    N. Bordel
    J. I. Martín
    C. Quirós
    A. Tempez
    A. Sanz-Medel
    [J]. Analytical and Bioanalytical Chemistry, 2010, 396 : 2881 - 2887
  • [8] Direct chemical in-depth profile analysis and thickness quantification of nanometer multilayers using pulsed-rf-GD-TOFMS
    Valledor, R.
    Pisonero, J.
    Bordel, N.
    Martin, J. I.
    Quiros, C.
    Tempez, A.
    Sanz-Medel, A.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (08) : 2881 - 2887
  • [9] Minor elements determination and evaluation of diffusion/segregation effects on ultra-thin layers using pulsed-RF-GD-TOFMS
    Pisonero, J.
    Licciardello, A.
    Hierro-Rodriguez, A.
    Quiros, C.
    Sanz-Medel, A.
    Bordel, N.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (08) : 1604 - 1609
  • [10] Ultra low energy arsenic implant limits on sheet resistance and junction depth
    Kasnavi, R
    Griffin, PB
    Plummer, JD
    [J]. 2000 SYMPOSIUM ON VLSI TECHNOLOGY, DIGEST OF TECHNICAL PAPERS, 2000, : 112 - 113