METHODS FOR USING 3-D ULTRASOUND SPECKLE TRACKING IN BIAXIAL MECHANICAL TESTING OF BIOLOGICAL TISSUE SAMPLES

被引:9
|
作者
Yap, Choon Hwai [1 ,3 ]
Park, Dae Woo [1 ]
Dutta, Debaditya [1 ]
Simon, Marc [2 ,4 ]
Kim, Kang [1 ,2 ,4 ,5 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Med, Ctr Ultrasound Mol Imaging & Therapeut, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Med Ctr UPMC, Inst Heart & Vasc, Pittsburgh, PA 15261 USA
[3] Natl Univ Singapore, Dept Biomed Engn, Singapore 117548, Singapore
[4] Univ Pittsburgh, Sch Engn, Dept Bioengn, Pittsburgh, PA 15261 USA
[5] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA 15261 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2015年 / 41卷 / 04期
关键词
3-D ultrasound speckle tracking; Biaxial mechanical testing; Constitutive relations; Soft tissue mechanics; MUSCLE-FIBER ORIENTATION; MAGNETIC-RESONANCE; PASSIVE MYOCARDIUM; CONSTITUTIVE RELATION; CONDUIT ARTERIES; RESIDUAL STRAINS; DISPLACEMENT; ARCHITECTURE; ELASTICITY;
D O I
10.1016/j.ultrasmedbio.2014.10.021
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Being multilayered and anisotropic, biological tissues such as cardiac and arterial walls are structurally complex, making the full assessment and understanding of their mechanical behavior challenging. Current standard mechanical testing uses surface markers to track tissue deformations and does not provide deformation data below the surface. In the study described here, we found that combining mechanical testing with 3-D ultrasound speckle tracking could overcome this limitation. Rat myocardium was tested with a biaxial tester and was concurrently scanned with high-frequency ultrasound in three dimensions. The strain energy function was computed from stresses and strains using an iterative non-linear curve-fitting algorithm. Because the strain energy function consists of terms for the base matrix and for embedded fibers, spatially varying fiber orientation was also computed by curve fitting. Using finite-element simulations, we first validated the accuracy of the non-linear curve-fitting algorithm. Next, we compared experimentally measured rat myocardium strain energy function values with those in the literature and found a matching order of magnitude. Finally, we retained samples after the experiments for fiber orientation quantification using histology and found that the results satisfactorily matched those computed in the experiments. We conclude that 3-D ultrasound speckle tracking can be a useful addition to traditional mechanical testing of biological tissues and may provide the benefit of enabling fiber orientation computation. (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1029 / 1042
页数:14
相关论文
共 50 条
  • [1] BIAXIAL MECHANICAL TESTING OF PORCINE SCLERA USING ULTRASOUND SPECKLE TRACKING FOR STRAIN MEASUREMENT
    Cruz-Perez, Benjamin
    Morris, Hugh J.
    Tang, Junhua
    Hart, Richard T.
    Pan, Xueliang
    Liu, Jun
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [2] BIAXIAL MECHANICAL TESTING OF BIOLOGICAL TISSUE
    HUNTER, PJ
    SMAILL, BH
    NIELSEN, PMF
    BIOPHYSICAL JOURNAL, 1986, 49 (02) : A90 - A90
  • [3] Biaxial mechanical testing of posterior sclera using high-resolution ultrasound speckle tracking for strain measurements
    Perez, Benjamin Cruz
    Tang, Junhua
    Morris, Hugh J.
    Palko, Joel R.
    Pan, Xueliang
    Hart, Richard T.
    Liu, Jun
    JOURNAL OF BIOMECHANICS, 2014, 47 (05) : 1151 - 1156
  • [4] Efficient Two-Pass 3-D Speckle Tracking for Ultrasound Imaging
    Jeng, Geng-Shi
    Zontak, Maria
    Parajuli, Nripesh
    Lu, Allen
    Ta, Kevinminh
    Sinusas, Albert J.
    Duncan, James S.
    O'Donnell, Matthew
    IEEE ACCESS, 2018, 6 : 17415 - 17428
  • [5] Comparison of calibration methods for spatial tracking of a 3-D ultrasound probe
    Poon, TC
    Rohling, RN
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (08): : 1095 - 1108
  • [6] Quantification of Coupled Stiffness and Fiber Orientation Remodeling in Hypertensive Rat Right-Ventricular Myocardium Using 3D Ultrasound Speckle Tracking with Biaxial Testing
    Park, Dae Woo
    Sebastiani, Andrea
    Yap, Choon Hwai
    Simon, Marc A.
    Kim, Kang
    PLOS ONE, 2016, 11 (10):
  • [7] 3-D correlation-based speckle tracking
    Chen, X
    Xie, H
    Erkamp, R
    Kim, K
    Jia, C
    Rubin, JM
    O'Donnell, M
    ULTRASONIC IMAGING, 2005, 27 (01) : 21 - 36
  • [8] Speckle classification for sensorless freehand 3-D ultrasound
    Hassenpflug, P
    Prager, RW
    Treece, GM
    Gee, AH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (11): : 1499 - 1508
  • [9] 3D Characterization of corneal deformation using ultrasound speckle tracking
    Clayson, Keyton
    Pavlatos, Elias
    Ma, Yanhui
    Liu, Jun
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2017, 10 (06)
  • [10] 3-D Ultrasound-Guided Robotic Needle Steering in Biological Tissue
    Adebar, Troy K.
    Fletcher, Ashley E.
    Okamura, Allison M.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (12) : 2899 - 2910