3D black-blood 3T-MRI for the diagnosis of abdominal large vessel vasculitis

被引:4
|
作者
Maurus, Stefan [1 ,6 ]
Sommer, Nora N. [1 ]
Kooijman, Hendrik [2 ]
Coppenrath, Eva [1 ]
Witt, Matthias [3 ]
Schulze-Koops, Hendrik [3 ]
Czihal, Michael [4 ]
Hoffmann, Ulrich [4 ]
Saam, Tobias [5 ]
Treitl, Karla M. [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiol, Marchioninistr 15, D-81377 Munich, Germany
[2] Philips Healthcare, Hamburg, Germany
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Med Clin & Policlin 4, Div Rheumatol & Clin Immunol, Munich, Germany
[4] Ludwig Maximilians Univ Munchen, Univ Hosp, Med Clin & Policlin 4, Div Vasc Med, Munich, Germany
[5] Radiol Zentrum Rosenheim, Rosenheim, Germany
[6] German Ctr Cardiovasc Dis Res DZHK eV, Munich, Germany
关键词
Vasculitis; Aortitis; Magnetic resonance imaging; MRI;
D O I
10.1007/s00330-019-06432-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To assess the value of a T1-3D black-blood turbo spin echo (TSE) sequence for the diagnosis of abdominal large vessel vasculitis (LVV). Materials and methods The study included 20 patients with abdominal LVV and 17 controls, who underwent a 3T-MRI scan using a modified T1-3D volumetric isotropic TSE acquisition and a segmented T1-3D turbo field echo sequence (T1-mVISTA/T1-eTHRIVE). Two radiologists independently analyzed the aorta for concentric contrast enhancement, concentric wall thickening, image quality, and flow artifact intensity (CCE/CWT/IQ/FAI; 4-point scales). The mean aortic wall thickness (MAWT) in post-contrast T1-mVISTA was compared between patients and controls. Results IQ of T1-mVISTA was rated good to excellent in 91.5% of 282 evaluated vessel segments with no or minor FAI present in 85.5%. The inter-observer reproducibility for the identification of CCE/CWT on T1-mVISTA was 0.92 and 0.93 (p < 0.001). The distribution of segmental inflammation in T1-mVISTA significantly correlated with T1-eTHRIVE (CCE, kappa = 0.768; CWT, kappa = 0.715; p < 0.001), resulting in a sensitivity, specificity, and positive predictive value of 100%, 81.3%, and 83.3%. The MAWT significantly differed between patients and controls (3.29 +/- 0.81 vs. 2.24 +/- 0.45 mm; p < 0.001). Conclusions T1-mVISTA enables the evaluation of the MAWT and allows the detection of abdominal LVV.
引用
收藏
页码:1041 / 1044
页数:4
相关论文
共 50 条
  • [31] Application of 3D Fast Spin-Echo T1 Black-Blood Imaging in the Diagnosis and Prognostic Prediction of Patients with Leptomeningeal Carcinomatosis
    Oh, J.
    Choi, S. H.
    Lee, E.
    Shin, D. J.
    Jo, S. W.
    Yoo, R-E.
    Kang, K. M.
    Yun, T. J.
    Kim, J-h
    Sohn, C-H
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (08) : 1453 - 1459
  • [32] Optimized 3D bright blood MRI of aortic plaque at 3 T
    Markl, Michael
    Dudler, Patrick
    Fydrychowicz, Alex
    Strecker, Christoph
    Weiller, Cornelius
    Hennig, Eirgen
    Harloff, Andreas
    MAGNETIC RESONANCE IMAGING, 2008, 26 (03) : 330 - 336
  • [33] Reproducibility and differentiation of cervical arteriopathies using in vivo high-resolution black-blood MRI at 3 T
    Schwarz, Florian
    Strobl, Frederik F.
    Cyran, Clemens C.
    Helck, Andreas D.
    Hartmann, Martin
    Schindler, Andreas
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Saam, Tobias
    NEURORADIOLOGY, 2016, 58 (06) : 569 - 576
  • [34] Reproducibility and differentiation of cervical arteriopathies using in vivo high-resolution black-blood MRI at 3 T
    Florian Schwarz
    Frederik F. Strobl
    Clemens C. Cyran
    Andreas D. Helck
    Martin Hartmann
    Andreas Schindler
    Konstantin Nikolaou
    Maximilian F. Reiser
    Tobias Saam
    Neuroradiology, 2016, 58 : 569 - 576
  • [35] Improved detection of brain metastases using contrast-enhanced 3D black-blood TSE sequences compared to post-contrast 3D T1 GRE: a comparative study on 1.5-T MRI
    Zhou, Zhao Hui Chen
    Alvarez, Elena Salvador
    Hilario, Amaya
    del Carre, Agustin Cardenas
    Coronado, Juan Romero
    Lechuga, Carmen
    de Aragon, Ana Martinez
    Gonzalez, Ana Ramos
    EUROPEAN RADIOLOGY, 2025,
  • [36] Large coverage black-bright blood interleaved imaging sequence (LaBBI) for 3D dynamic contrast-enhanced MRI of vessel wall
    Qi, Haikun
    Huang, Feng
    Zhou, Zechen
    Koken, Peter
    Balu, Niranjan
    Zhang, Bida
    Yuan, Chun
    Chen, Huijun
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1334 - 1344
  • [37] Diagnostic Accuracy of High-Resolution Black-Blood MRI in the Evaluation of Intracranial Large-Vessel Arterial Occlusions
    Al-Smadi, A. S.
    Abdalla, R. N.
    Elmokadem, A. H.
    Shaibani, A.
    Hurley, M. C.
    Potts, M. B.
    Jahromi, B. S.
    Carroll, T. J.
    Ansari, S. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (06) : 954 - 959
  • [38] Intracranial black-blood MR angiography with high-resolution 3D fast spin echo
    Alexander, AL
    Buswell, HR
    Sun, Y
    Chapman, BE
    Tsuruda, TS
    Parker, DL
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) : 298 - 310
  • [39] The development and optimisation of 3D black-blood R2* mapping of the carotid artery wall
    Yuan, Jianmin
    Graves, Martin J.
    Patterson, Andrew J.
    Priest, Andrew N.
    Ruetten, Pascal P. R.
    Usman, Ammara
    Gillard, Jonathan H.
    MAGNETIC RESONANCE IMAGING, 2017, 44 : 104 - 110
  • [40] 3D high-resolution atrial wall thickness maps using black-blood PSIR
    Marta Varela
    Christoph Kolbitsch
    Adeline Theron
    Ross Morgan
    Markus Henningsson
    Tobias Schaeffter
    Oleg Aslanidi
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)