Using ozone air cleaners to remove indoor volatile organic compounds

被引:0
|
作者
Yu, KP [1 ]
Lee, GWM [1 ]
Hsieh, CP [1 ]
Yang, SH [1 ]
机构
[1] Natl Taiwan Univ, Grad Inst Environm Engn, Taipei 10764, Taiwan
关键词
ozone air cleaner; toluene; formaldehyde; removal efficiency environmental test chamber;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor volatile organic compounds (VOCs) are known to cause many human health problems. Ozone air cleaners were claimed to remove the indoor VOCs, but their effectiveness was still unclear. In this study, we selected six ozone air cleaners to evaluate their effectiveness on the control of target VOCs (toluene and formaldehyde). The experiments were conducted in a 11.3-m(3) stainless steel environmental test chamber under 25 degrees C and 60% relative humidity. The clean air delivery rate for toluene and formaldehyde ranged from 0.0565 to 0.424 m(3)/hr, and from 0.0068 to 0.747 m(3)/hr, respectively. The removal rates observed were much high than the removal rates based on the ozone-toluene and ozone-formaldehyde reaction constants measured in previous studies. Thus, the removal of toluene and formaldehyde may result from the other mechanism such as adsorption, and high-voltage electric discharge or ultraviolet lamp, used to generate ozone.
引用
收藏
页码:2981 / 2985
页数:5
相关论文
共 50 条
  • [21] CONCENTRATIONS OF VOLATILE ORGANIC-COMPOUNDS IN INDOOR AIR - A REVIEW
    BROWN, SK
    SIM, MR
    ABRAMSON, MJ
    GRAY, CN
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02): : 123 - 134
  • [22] Volatile organic compounds in the indoor air of warsaw office buildings
    Posniak, M
    Makhniashvili, I
    Koziel, E
    INDOOR AND BUILT ENVIRONMENT, 2005, 14 (3-4) : 269 - 275
  • [23] VOLATILE ORGANIC-COMPOUNDS IN INDOOR AIR AND IN EXPIRED AIR AS MARKERS OF ACTIVITIES
    CAILLEUX, A
    TURCANT, A
    PREMELCABIC, A
    ALLAIN, P
    CHROMATOGRAPHIA, 1993, 37 (1-2) : 57 - 59
  • [24] Quantile regression of indoor air concentrations of volatile organic compounds (VOC)
    Schlink, Uwe
    Thiem, Alexander
    Kohajda, Tibor
    Richter, Matthias
    Strebel, Kathrin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2010, 408 (18) : 3840 - 3851
  • [25] Diffusive sampling and measurement of microbial volatile organic compounds in indoor air
    Araki, A.
    Eitaki, Y.
    Kawai, T.
    Kanazawa, A.
    Takeda, M.
    Kishi, R.
    INDOOR AIR, 2009, 19 (05) : 421 - 432
  • [26] Determination of volatile organic compounds in indoor and ambient air of residences in Kuwait
    Bouhamra, WS
    BuHamra, SS
    Thomson, MS
    ENVIRONMENT INTERNATIONAL, 1997, 23 (02) : 197 - 204
  • [27] The use of volatile organic compounds as an indicator in indoor air quality investigations
    Popa, M
    Popa, MS
    SEVENTH INTERNATIONAL SYMPOSIUM ON LASER METROLOGY APPLIED TO SCIENCE, INDUSTRY, AND EVERYDAY LIFE, PTS 1 AND 2, 2002, 4900 : 1090 - 1093
  • [28] Total volatile organic compounds (TVOC) in indoor air quality investigations
    Molhave, L
    Clausen, G
    Berglund, B
    de Ceaurriz, J
    Kettrup, A
    Lindvall, T
    Maroni, M
    Pickering, AC
    Risse, U
    Rothweiler, H
    Seifert, B
    Younes, M
    INDOOR AIR, 1997, 7 (04) : 225 - 240
  • [29] VOLATILE ORGANIC-COMPOUNDS IN THE INDOOR AIR OF NORMAL AND SICK HOUSES
    KOSTIAINEN, R
    ATMOSPHERIC ENVIRONMENT, 1995, 29 (06) : 693 - 702
  • [30] Photocatalytic purification of volatile organic compounds in indoor air: A literature review
    Mo, Jinhan
    Zhang, Yinping
    Xu, Qiujian
    Lamson, Jennifer Joaquin
    Zhao, Rongyi
    ATMOSPHERIC ENVIRONMENT, 2009, 43 (14) : 2229 - 2246