Analysis of microstructure and fatigue of cast versus selective laser-melted dental Co-Cr alloy

被引:16
|
作者
Wu, Miaomiao [1 ]
Dong, Xin [1 ]
Qu, Yuntao [1 ]
Yan, Jiazhen [1 ]
Li, Ning [1 ]
机构
[1] Sichuan Univ, Sch Mech Engn, 24 South Rd,Yihuan Rd, Chengdu 610065, Sichuan, Peoples R China
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 128卷 / 02期
关键词
MECHANICAL-PROPERTIES; HEAT-TREATMENT; MO; GROWTH; MORPHOLOGY; STRENGTH;
D O I
10.1016/j.prosdent.2022.05.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The forces exerted on teeth and prostheses during mastication are repeated and dynamic, resulting in fatigue damage to dental prostheses. Most fractures of dental restorations are fatigue failure. The 4-point bend fatigue behavior of Co-Cr-Mo-W alloys manufactured by investment casting (CAST) and selective laser melting (SLM) has received little attention. Purpose. The purpose of this in vitro study was to evaluate the 4-point bend fatigue property of dental Co-Cr alloys and determine the relationship between microstructure and the 4-point bend fatigue property of Co-Cr alloys created by traditional casting and SLM. These can guide the use of Co-Cr alloy in dentistry. Material and methods. Co-Cr-Mo-W alloys were fabricated with a dimension of 45x2x2 mm by investment casting and SLM. The 3-point bend test measured the ultimate bend strength with 3 specimens in each group. The 4-point bend fatigue test evaluated the fatigue life under various stresses, with 6 specimens in each group. The specimens were mechanically ground, polished, and electrochemically etched. Scanning electron microscopy was used to identify the microstructures of both etched specimens and fracture surfaces. X-ray diffraction investigations were used to determine the phases. Significant differences in the bend strength were analyzed by using the independent samples t test (alpha=.05), and the fatigue test was analyzed with ANCOVA (alpha=.05). Results. The mean +/- standard deviation bend strength of SLM specimens was 1837 +/- 3 MPa, higher than the 1200 +/- 6 MPa for CAST specimens (P<.05). The maximum bend stress of the SLM specimens without fatigue failure was 735 MPa, which was statistically higher than the 394 MPa for CAST specimens (P<.05). The microstructure characteristics of the SLM alloy contributed to its excellent fatigue performance. In SLM alloy, the gamma phase constituted the majority with some epsilon and Laves phases, while the cast alloy possessed higher epsilon and Laves phases. The grains of SLM alloy were equiaxed and fine, and the second phases were fine and dispersive. In contrast, the cast alloy possessed clear dendrites, and the second phases were sizable. Conclusions. The SLM dental Co-Cr-Mo-W alloy had statistically better 4-point bend fatigue properties than cast alloy, which was associated with an improved microstructure.
引用
收藏
页码:218.e1 / 218.e7
页数:7
相关论文
共 50 条
  • [1] Corrosion characteristics of a selective laser melted Co-Cr dental alloy under physiological conditions
    Xin, Xian-zhen
    Xiang, Nan
    Chen, Jie
    Xu, Dan
    Wei, Bin
    JOURNAL OF MATERIALS SCIENCE, 2012, 47 (12) : 4813 - 4820
  • [2] Surface characteristics and corrosion properties of selective laser melted Co-Cr dental alloy after porcelain firing
    Xin, X-Z
    Chen, J.
    Xiang, N.
    Gong, Y.
    Wei, B.
    DENTAL MATERIALS, 2014, 30 (03) : 263 - 270
  • [3] Failure of ceramic coatings on cast and selective laser melted Co-Cr dental alloys under tensile test: Experiment and finite element analysis
    Dikova, Tsanka
    Vasilev, Tihomir
    Dolgov, Nikolay
    ENGINEERING FAILURE ANALYSIS, 2019, 105 : 1045 - 1054
  • [4] Effects of rapid infrared radiation heating on the warping deformation and mechanical properties of selective laser melted Co-Cr dental alloy
    Zhou, Yanan
    Liu, Zhihao
    Du, Huwei
    Jiang, Jie
    Li, Jianxin
    Ma, Xiaoyu
    Yi, Yunchao
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 907e1 - 907e9
  • [5] Impact of Porcelain Firing Cycling on the Microstructure and Mechanical Properties of Selective Laser-Melted Co-Cr-Mo-W Dental Alloys
    Wei, Wei
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2024,
  • [6] MICROSTRUCTURE FEATURES OF DENTAL PROSTHESES FROM Co-Cr BASED ALLOY AFTER SELECTIVE LASER MELTING AND THERMAL TREATMENT
    Drapala, Jaromir
    Losertova, Monika
    Rodryc, Vojtech
    Konecna, Katerina
    Svoboda, Rostislav
    Mahdal, Ondrej
    METAL 2016: 25TH ANNIVERSARY INTERNATIONAL CONFERENCE ON METALLURGY AND MATERIALS, 2016, : 1374 - 1381
  • [7] Effect of Selective Laser Melting Process Parameters on Microstructure and Properties of Co-Cr Alloy
    Wang, Jian-Hong
    Ren, Jie
    Liu, Wei
    Wu, Xiao-Yu
    Gao, Ming-Xiang
    Bai, Pei-Kang
    MATERIALS, 2018, 11 (09)
  • [8] Orientation dependence of microstructure and mechanical property in selective laser-melted Inconel 718 alloy
    Deng, Hai
    Wang, Yan
    Lv, Liangxing
    Zhang, Shuai
    Bian, Qin
    Luo, Jingzhen
    Wu, Ziyu
    Liu, Zhi
    Chen, Zhihui
    Tan, Liming
    Liu, Feng
    MATERIALS CHARACTERIZATION, 2025, 220
  • [9] Corrosion characteristics of a selective laser melted Co–Cr dental alloy under physiological conditions
    Xian-zhen Xin
    Nan Xiang
    Jie Chen
    Dan Xu
    Bin Wei
    Journal of Materials Science, 2012, 47 : 4813 - 4820
  • [10] Effect of Laser Power and Scanning Speed on Microstructure and Properties of Co-Cr Alloy by Selective Laser Melting
    Deng Y.-H.
    Li Z.-H.
    Yao B.-B.
    Teng B.-R.
    Li H.
    Surface Technology, 2023, 52 (01): : 325 - 335