Application of direct analysis in real-time mass spectrometry (DART-MS) in forensic science: a comprehensive review

被引:10
|
作者
Gupta, Swati [1 ]
Samal, Nilimamayee [1 ]
机构
[1] LNJN Natl Inst Criminol & Forens Sci, Dept Forens Sci, New Delhi 110085, India
关键词
Forensic science; Direct analysis in real-time; Mass spectrometry; DART-MS; DESORPTION ELECTROSPRAY-IONIZATION; COLLISION-INDUCED DISSOCIATION; SOLID-PHASE MICROEXTRACTION; CHEMICAL WARFARE AGENTS; RAPID DETECTION; LATENT FINGERMARKS; SCREENING METHOD; URINE SAMPLES; WRITING INKS; IDENTIFICATION;
D O I
10.1186/s41935-022-00276-4
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Background: As the rate of crime is constantly increasing, the workload on the forensic analyst also piles up. The availability of a limited number of seized samples makes it crucial to directly analyze the sample, thereby preventing wastage in the prior steps of sample preparation. Due to such needs, the forensic community is consistently working on broadening the usage of direct analysis in real-time mass spectrometry (DART-MS). DART-MS is a relatively new technique for rapid mass spectral analysis. Its use for chemical analysis credits its ability to analyze the sample at atmospheric pressure. Main body: This article gives insight into the ionization mechanisms, data analysis tools, and the use of hyphenated techniques like thermal-desorption-DART-MS, infrared-thermal-desorption-DART-MS, Joule-heating thermal-desorption-DART-MS, etc. This review summarizes the applications of DART-MS in the field of Forensic Science reported from 2005 to 2021. The applications include analysis of drugs, warfare agents, gun-shot residues, ink differentiation, and other forensically relevant samples. The paper also presents the relation between the type of DART-MS technique and the ionization mode used for a particular class of compounds. Conclusion: The review follows that the high-resolution mass-spectrometers or low-resolution mass-spectrometers systems in the positive or negative mode were highly dependent on the type of analyte under investigation. Drugs, inks, dyes, and paints were mainly analyzed using the positive ionization mode in the HRMS technique. The examinations of fire accelerants predominantly used the positive ionization mode in the LRMS technique. Moreover, the limit of detection values obtained from the qualitative screening of street drugs were of ppb level, indicating high sensitivity of DART-MS. Considering the work done in the past years, there are potential future research needs of this technology, especially in forensic science.
引用
收藏
页数:25
相关论文
共 50 条
  • [21] Identification of the Country of Growth of Sophora flavescens using Direct Analysis in Real Time Mass Spectrometry (DART-MS)
    Fukuda, Eriko
    Uesawa, Yoshihiro
    Baba, Masaki
    Suzuki, Ryuichiro
    Fukuda, Tatsuo
    Shirataki, Yoshiaki
    Okada, Yoshihito
    NATURAL PRODUCT COMMUNICATIONS, 2014, 9 (11) : 1591 - 1594
  • [22] Detection of ricin and abrin toxin by laboratory-based and portable direct analysis in real-time mass spectrometry (DART-MS)
    Sekowski, Jennifer
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [23] Detection of carob flour in cocoa powder by direct analysis in real time-mass spectrometry (DART-MS)
    Maragos, Chris M.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2025, 42 (03): : 293 - 305
  • [24] Improvement in ionization efficiency of direct analysis in real time-mass spectrometry (DART-MS) by corona discharge
    Sekimoto, Kanako
    Sakakura, Motoshi
    Kawamukai, Takatomo
    Hike, Hiroshi
    Shiota, Teruhisa
    Usui, Fumihiko
    Bando, Yasuhiko
    Takayama, Mitsuo
    ANALYST, 2016, 141 (16) : 4879 - 4892
  • [25] Direct analysis in real time mass spectrometry (DART-MS) of discrete sample areas without heat damage
    Newsome, G. Asher
    Kayama, Ikumi
    Brogdon-Grantham, Shannon A.
    ANALYTICAL METHODS, 2018, 10 (09) : 1038 - 1045
  • [26] A rapid screening of histamine concentration in fish fillet by direct analysis in real time mass spectrometry (DART-MS)
    Nei, Daisuke
    Nakamura, Nobutaka
    Ishihara, Kenji
    Kimura, Meiko
    Satomi, Masataka
    FOOD CONTROL, 2017, 75 : 181 - 186
  • [27] Yiyang Dong (Ed.): Direct analysis in real time mass spectrometry: principles and practices of DART-MS
    Gross J.H.
    Analytical and Bioanalytical Chemistry, 2018, 410 (27) : 6975 - 6976
  • [28] Nitrogen-Activated Oxidation in Nitrogen Direct Analysis in Real Time Mass Spectrometry (DART-MS) and Rapid Detection of Explosives Using Thermal Desorption DART-MS
    An, ShuQi
    Liu, Shuai
    Cao, Jie
    Lu, ShiFang
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2019, 30 (10) : 2092 - 2100
  • [29] Direct quantitative analysis of the natural moisturizing factor (NMF) in the stratum corneum by direct analysis in real time mass spectrometry (DART-MS)
    Maeno, Katsuyuki
    Shida, Yasuo
    Shimada, Haruo
    ANALYTICAL METHODS, 2017, 9 (33) : 4851 - 4857
  • [30] Direct analysis in real time mass spectrometry (DART-MS) for rapid screening of Carpaine in Carica papaya leaf products
    Khaoiam, Piyawadi
    Andriyas, Tushar
    Thanusuwannasak, Thanundorn
    Puangnil, Nalinrat
    Limpikirati, Patanachai K.
    Tansawat, Rossarin
    FOOD CHEMISTRY, 2025, 463