Treatment of Neer IIb Distal Clavicle Fractures Using Anatomical Locked Plate Fixation With Coracoclavicular Ligament Augmentation

被引:24
|
作者
Han, Lei [1 ]
Hu, Yungen [1 ]
Quan, Renfu [1 ]
Fang, Weili [1 ]
Jin, Bo [1 ]
Huang, Ligang [2 ]
机构
[1] Xiaoshan Tradit Chinese Med Hosp, Dept Orthopaed Inst, 152 Yucai Rd, Hangzhou 311200, Zhejiang, Peoples R China
[2] Sixth Peoples Hosp Xiaoshan, Dept Orthopaed Inst, Hangzhou, Zhejiang, Peoples R China
来源
关键词
Anatomical locking plate; coracoclavicular ligament augmentation; distal clavicle fracture; Neer type IIb; suture anchor; SURGICAL-TREATMENT; LOCKING PLATE; ACROMIOCLAVICULAR JOINT; SCREW FIXATION; HOOK PLATE;
D O I
10.1016/j.jhsa.2017.08.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The purpose of this study was to evaluate the clinical and radiographic outcomes of Neer type IIb distal clavicle fractures treated with anatomical locking plate fixation combined with coracoclavicular ligament augmentation. Methods Twelve patients with Neer Type IIb distal clavicle fractures treated with anatomical locking plate fixation combined with suture anchor augmentation of the coracoclavicular ligament, were retrospectively studied. Clinical outcomes were assessed using the Constant score and the Disabilities of the Arm, Shoulder, and Hand (DASH) score. Coracoclavicular distance was measured on plain radiographs. Results All patients were reexamined at a mean follow-up of 26.3 months (range, 25-30 months). Bony union occurred in all cases within 12 weeks and no major complications were encountered. At the final follow-up, the mean Constant score was 94 (range, 87-100) and the DASH score was 10.4 (range, 2-20). The mean postoperative coracoclavicular distance on the injured side was decreased by 40% compared with the preoperative status. Conclusions Surgical fixation of Neer type IIb distal clavicle fractures using anatomical locking plate fixation combined with suture anchor augmentation of the coracoclavicular ligament was associated with a satisfactory functional outcome and low complication rate. Copyright (C) 2017 by the American Society for Surgery of the Hand. All rights reserved.
引用
下载
收藏
页码:1036.e1 / 1036.e6
页数:6
相关论文
共 50 条
  • [31] Comparative analysis of a locking plate with an all-suture anchor versus hook plate fixation of Neer IIb distal clavicle fractures
    Seo, Joong-Bae
    Kwak, Kwon-young
    Yoo, Jae-Sung
    JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (03)
  • [32] Comparison of single coracoclavicular suture fixation and hook plate for the treatment of acute unstable distal clavicle fractures
    Chun-Yu Chen
    Shan-Wei Yang
    Kuan-Yu Lin
    Kai-Cheng Lin
    Yih-Wen Tarng
    Jenn-Huei Renn
    Chia-Hsin Lai
    Journal of Orthopaedic Surgery and Research, 9
  • [33] Treatment of unstable distal clavicle fractures (Neer type IIb): a modified system using a miniature locking plate with a single button
    Ying, Hua
    Wang, Jihuan
    Sun, Yuehua
    Dai, Kerong
    Yu, Chao
    Yang, Fei
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (06)
  • [34] Clavicle hook plate versus distal clavicle locking plate for Neer type II distal clavicle fractures
    Li, Liang
    Li, Tian-yan
    Jiang, Peichao
    Lin, Guizhen
    Wu, Hongxiao
    Han, Xiaochuan
    Yu, Xuezhong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)
  • [35] Treatment of Acute Unstable Distal Clavicle Fractures With Single Coracoclavicular Suture Fixation
    Yang, Shan-Wei
    Lin, Li Chun
    Chang, Shwu Jen
    Kuo, Shyh Ming
    Hwang, Lain-Chyr
    ORTHOPEDICS, 2011, 34 (06) : 436 - 436
  • [36] Clavicle hook plate versus distal clavicle locking plate for Neer type II distal clavicle fractures
    Liang Li
    Tian-yan Li
    Peichao Jiang
    Guizhen Lin
    Hongxiao Wu
    Xiaochuan Han
    Xuezhong Yu
    Journal of Orthopaedic Surgery and Research, 14
  • [37] Comparing the coracoclavicular loop technique with a hook plate for the treatment of distal clavicle fractures
    Hsu, Kuei-Hsiang
    Tzeng, Yun-Hsuan
    Chang, Ming-Chau
    Chiang, Chao-Ching
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (02) : 224 - 230
  • [38] Clinical and radiological results on the fixation of Neer type 2 distal clavicle fractures with a hook plate
    Sukur, Erhan
    Ozturkmen, Yusuf
    Akman, Yunus Emre
    Gungor, Mustafa
    Acta Orthopaedica et Traumatologica Turcica, 2016, 50 (05) : 489 - 493
  • [39] Distal Clavicle Fracture Repair Using Cortical Button Fixation With Coracoclavicular Ligament Reconstruction
    Yagnik, Gautam P.
    Porter, David A.
    Jordan, Charles J.
    ARTHROSCOPY TECHNIQUES, 2018, 7 (04): : E411 - E415
  • [40] Analysis of the efficacy of Endobutton plate combined with high-strength suture Nice knot fixation in the treatment of distal clavicle fractures with coracoclavicular ligament injuries
    Bin Liu
    Lei Shi
    Huifang Ma
    Haiyang Yu
    Jishi Jiang
    BMC Musculoskeletal Disorders, 25 (1)