Improvements in CBCT Image Quality Using a Novel Iterative Reconstruction Algorithm: A Clinical Evaluation

被引:54
|
作者
Gardner, Stephen J. [1 ]
Mao, Weihua [1 ]
Liu, Chang [1 ]
Aref, Ibrahim [1 ]
Elshaikh, Mohamed [1 ]
Lee, Joon K. [1 ]
Pradhan, Deepak [1 ]
Movsas, Benjamin [1 ]
Chetty, Indrin J. [1 ]
Siddiqui, Farzan [1 ]
机构
[1] Henry Ford Hlth Syst, Josephine Ford Canc Inst, Dept Radiat Oncol, 2799 W Grand Blvd, Detroit, MI 48202 USA
关键词
BEAM COMPUTED-TOMOGRAPHY; HEAD-AND-NECK; SCATTERED RADIATION; LINEAR-ACCELERATOR; CT IMAGES; DELINEATION; RADIOTHERAPY; SEGMENTATION; VARIABILITY; THERAPY;
D O I
10.1016/j.adro.2018.12.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study aimed to evaluate the clinical utility of a novel iterative cone beam computed tomography (CBCT) reconstruction algorithm for prostate and head and neck (HN) cancer. Methods and Materials: A total of 10 patients with HN and 10 patients with prostate cancer were analyzed. For each patient, raw CBCT acquisition data were used to reconstruct images with a currently available algorithm (FDK_CBCT) and novel iterative algorithm (Iterative_CBCT). Quantitative contouring variation analysis was performed using structures delineated by several radiation oncologists. For prostate, observers contoured the prostate, proximal 2 cm seminal vesicles, bladder, and rectum. For HN, observers contoured the brain stem, spinal canal, right-left parotid glands, and right-left submandibular glands. Observer contours were combined to form a reference consensus contour using the simultaneous truth and performance level estimation method. All observer contours then were compared with the reference contour to calculate the Dice coefficient, Hausdorff distance, and mean contour distance (prostate contour only). Qualitative image quality analysis was performed using a 5-point scale ranging from 1 (much superior image quality for Iterative_CBCT) to 5 (much inferior image quality for Iterative_CBCT). Results: The Iterative_CBCT data sets resulted in a prostate contour Dice coefficient improvement of approximately 2.4% (P = .029). The average prostate contour Dice coefficient for the Iterative_CBCT data sets was improved for all patients, with improvements up to approximately 10% for 1 patient. The mean contour distance results indicate an approximate 15% reduction in mean contouring error for all prostate regions. For the parotid contours, Iterative_CBCT data sets resulted in a Hausdorff distance improvement of approximately 2 mm (P < .01) and an approximate 2% improvement in Dice coefficient (P = .03). The Iterative_CBCT data sets were scored as equivalent or of better image quality for 97.3% (prostate) and 90.0% (HN) of the patient data sets. Conclusions: Observers noted an improvement in image uniformity, noise level, and overall image quality for Iterative_CBCT data sets. In addition, expert observers displayed an improved ability to consistently delineate soft tissue structures, such as the prostate and parotid glands. Thus, the novel iterative reconstruction algorithm analyzed in this study is capable of improving the visualization for prostate and HN cancer image guided radiation therapy. (C) 2019 The Authors. Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.
引用
收藏
页码:390 / 400
页数:11
相关论文
共 50 条
  • [31] Simultaneous deblurring and iterative reconstruction of CBCT for image guided brain radiosurgery
    Hashemi, SayedMasoud
    Song, William Y.
    Sahgal, Arjun
    Lee, Young
    Huynh, Christopher
    Grouza, Vladimir
    Nordstrom, Hakan
    Eriksson, Markus
    Dorenlot, Antoine
    Regis, Jean Marie
    Mainprize, James G.
    Ruschin, Mark
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (07): : 2521 - 2541
  • [32] Dose Reduction and Low-Contrast Detectability Using Iterative CBCT Reconstruction Algorithm for Radiotherapy
    Washio, Hayate
    Ohira, Shingo
    Funama, Yoshinori
    Ueda, Yoshihiro
    Morimoto, Masahiro
    Kanayama, Naoyuki
    Isono, Masaru
    Inui, Shoki
    Nitta, Yuya
    Miyazaki, Masayoshi
    Teshima, Teruki
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [33] A NOVEL ITERATIVE IMAGE RESTORATION ALGORITHM USING NONSTATIONARY IMAGE PRIORS
    Vera, Esteban
    Vega, Miguel
    Molina, Rafael
    Katsaggelos, Aggelos K.
    2011 18TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2011,
  • [34] Deblurring in Iterative Reconstruction of Half CBCT for Image Guided Brain Radiosurgery
    Hashemi, SayedMasoud
    Lee, Young
    Eriksson, Markus
    Nordstrom, Hakan
    Song, Bongyong
    Nam, Wooseok
    Sahgal, Arjun
    Song, William
    Ruschin, Mark
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [35] An Analysis of the Commercially Available CBCT Based On Iterative Reconstruction Algorithm for IGRT
    Kang, S.
    Chung, J.
    Lee, S.
    Kang, S.
    Suh, T.
    Kim, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E152 - E152
  • [36] Image quality assessment of an iterative reconstruction algorithm applied to abdominal CT imaging
    Funama, Yoshinori
    Taguchi, Katsuyuki
    Utsunomiya, Daisuke
    Oda, Seitaro
    Katahira, Kazuhiro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (04): : 527 - 534
  • [37] Hybrid Iterative Reconstruction Algorithm Improves Image Quality in Craniocervical CT Angiography
    Love, Askell
    Siemund, Roger
    Hoglund, Peter
    Ramgren, Birgitta
    Undren, Per
    Bjorkman-Burtscher, Isabella M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (06) : W861 - W866
  • [38] Quantifying Differences in Image Quality Between Filtered Backprojection, An Adaptive Iterative Reconstruction Algorithm, and a Model-Based Iterative Reconstruction Algorithm for CT
    Whitson, H.
    Griglock, T.
    DeWeese, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3113 - 3113
  • [39] Novel iterative image reconstruction algorithm for electrical capacitance tomography: Directional algebraic reconstruction technique
    Kim, Ji Hoon
    Choi, Bong Yeol
    Kim, Kyung Youn
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2006, E89A (06): : 1578 - 1584
  • [40] Characterizations of image quality for CT with iterative reconstruction algorithm - development of a routine quality control metric
    Yang, Chang-Ying Joseph
    Bjarnason, Thorarin Albert
    MEDICAL PHYSICS, 2014, 41 (08) : 7 - 7