Perfusion quantification using dynamic contrast-enhanced ultrasound: The impact of dynamic range and gain on time-intensity curves

被引:57
|
作者
Gauthier, Thomas P. [1 ,2 ]
Averkiou, Michalakis A. [3 ]
Leen, Edward L. S. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp, Imaging Sci Dept, Clin Sci Div,Fac Med, London W12 0NN, England
[2] Philips Ultrasound, Dept Res & Dev, Bothell, WA 98021 USA
[3] Univ Cyprus, Dept Mech Engn, CY-2111 Nicosia, Cyprus
关键词
Ultrasound contrast agents; Perfusion quantification; Liver malignancy; Therapy monitoring; BLOOD-FLOW; GUIDELINES; CARCINOMA; AGENTS;
D O I
10.1016/j.ultras.2010.06.004
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objective of this study was to assess the impact of dynamic range and gain on perfusion quantification using linearized log-compressed data. An indicator-dilution experiment was developed with an in vitro flow phantom setup used with SonoVue contrast agent (Bracco SpA, Milan, Italy). Imaging was performed with a Philips iU22 scanner and a C5-1 curvilinear transducer using a contrast-specific nonlinear pulse sequence (power modulation) at 1.7 MHz. Clinical dynamic contrast-enhanced ultrasound image loops of liver tumors were also collected for preliminary validation of the in vitro findings. Time-intensity curves were extracted from image loops with two different approaches: from linearized log-compressed data and from linear (uncompressed) data. The error of time-intensity curve parameters derived from linearized log-compressed data (deviation from linear data) was found to be less than 2.1% and 5.4% for all studied parameters in the in vitro experiment and in the clinical study, respectively, when a high dynamic range setting (at least 50 dB on the iU22) is used. The gain must be carefully adjusted to ensure a high signal-to-noise ratio and to avoid signal saturation. From the time-intensity curve analysis it was also found that rise time of the bolus time-intensity curve is the least variable of all the studied time-intensity curve parameters. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:102 / 106
页数:5
相关论文
共 50 条
  • [31] Effects of k-space orders on the time-intensity curves in dynamic contrast-enhanced magnetic resonance imaging of the breast based on simulation study
    Takatsu, Yasuo
    Ueyama, Tsuyoshi
    Iwasaki, Takahiro
    Asahara, Masaki
    Honda, Michitaka
    Miyati, Tosiaki
    MAGNETIC RESONANCE IMAGING, 2021, 79 : 85 - 96
  • [32] Contrast-enhanced ultrasound for quantification of tissue perfusion in humans
    Emanuel, Anna L.
    Meijer, Rick, I
    van Poelgeest, Erik
    Spoor, Pien
    Serne, Erik H.
    Eringa, Etto C.
    MICROCIRCULATION, 2020, 27 (01)
  • [33] Impact of Recirculation in Dynamic Contrast-Enhanced Ultrasound: A Simulation Study
    Doury, M.
    de Cesare, A.
    Bridal, S. Lori
    Pellot-Barakat, C.
    Frouin, F.
    IRBM, 2017, 38 (04) : 179 - 189
  • [34] CONTRAST ENHANCED ULTRASOUND USING A TIME-INTENSITY CURVE FOR DIAGNOSIS OF RENAL MASSES
    Aoki, Shigeyuki
    Yamamoto, Tokunori
    Funahashi, Yasuhito
    Hattori, Ryohei
    Gotoh, Momokazu
    JOURNAL OF UROLOGY, 2009, 181 (04): : 250 - 251
  • [35] Correlations between the time-intensity parameters of contrast-enhanced ultrasound and clinical prognosis of hepatocellular carcinoma
    Yang, Yi-Lin
    Yang, Rui-Jing
    Liu, Xi
    Liu, Jie
    Chao, Li-Juan
    Duan, Yun-You
    CLINICAL IMAGING, 2013, 37 (02) : 308 - 312
  • [36] Value of time-intensity curve analysis of contrast-enhanced ultrasound in the differential diagnosis of thyroid nodules
    Gu, Fen
    Han, Lu
    Yang, Xiao
    Liu, Haijing
    Li, Xiaoyu
    Guo, Kai
    Zhao, Zhen
    Zhou, Xiaodong
    Luo, Wen
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 182 - 187
  • [37] In vitro evaluation of the impact of ultrasound scanner settings and contrast bolus volume on time-intensity curves
    Gauthier, Thomas P.
    Chebil, Mohamed
    Peronneau, Pierre
    Lassau, Nathalie
    ULTRASONICS, 2012, 52 (01) : 12 - 19
  • [38] Myocardial perfusion by contrast-enhanced echocardiography and dynamic contrast-enhanced MR imaging
    Lombardi, M
    Rovai, D
    Rinck, PA
    LAbbate, A
    ACTA RADIOLOGICA, 1997, 38 : 79 - 84
  • [39] High Resolution Ultrasound Superharmonic Perfusion Imaging: In Vivo Feasibility and Quantification of Dynamic Contrast-Enhanced Acoustic Angiography
    Lindsey, Brooks D.
    Shelton, Sarah E.
    Martin, K. Heath
    Ozgun, Kathryn A.
    Rojas, Juan D.
    Foster, F. Stuart
    Dayton, Paul A.
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (04) : 939 - 948
  • [40] Differentiation of malignant liver tumors by software-based perfusion quantification with dynamic contrast-enhanced ultrasound (DCEUS)
    Wildner, Dane
    Schellhaas, Barbara
    Strack, Daniel
    Goertz, Ruediger S.
    Pfeifer, Lukas
    Fiessler, Cornelia
    Neurath, Markus F.
    Strobel, Deike
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2019, 71 (01) : 39 - 51