Physical analysis of breast cancer using dual-source computed tomography

被引:1
|
作者
Kim, H. J. [1 ]
Lee, H. K. [2 ]
Cho, J. H. [3 ]
机构
[1] Soonchunhyang Univ Hosp, Dept Radiol, Puchon, South Korea
[2] Soonchunhyang Univ, Dept Comp Sci & Engn, Asan, South Korea
[3] Hallym Univ Grad Studies, Dept Int Radiol Sci, Seoul, South Korea
来源
关键词
Hounsfield Unit; breast cancer; physical characteristics; dual-source CT; IMAGE QUALITY; CT; COVERAGE; PHANTOM; VOLUME; MDCT;
D O I
10.1080/10420150.2014.977283
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study was aimed to analyze various physical characteristics of breast cancer using dual-source computed tomography (CT). A phantom study and a clinical trial were performed in order and a 64-multidetector CT device was used for the examinations. In the phantom study, single-source (SS) CT was set up with a conventional scanning condition that is usually applied for breast CT examination and implementation was done at tube voltage of 120 kVp. Dual-source CT acquired images by irradiating X-ray sources with fast switching between two kilovoltage settings (80 and 140 kVp). After scanning, Hounsfield Unit (HU) values and radiation doses in a region of interest were measured and analyzed. In the clinical trial, the HU values were measured and analyzed after single-source computed tomography (SSCT) and dual-source CT in patients diagnosed with breast cancer. Also, the tumor size measured by dual-source CT was compared with the actual tumor size. The phantom study determined that the tumor region was especially measured by dual-source CT, while nylon fiber and specks region were especially measured by SSCT. The radiation dose was high with dual-source CT. The clinical trial showed a higher HU value of cancerous regions when scanned by dual-source CT compared with SSCT.
引用
收藏
页码:994 / 1002
页数:9
相关论文
共 50 条
  • [41] Carotid Plaque Analysis: Comparison of Dual-Source Computed Tomography (CT) Findings and Histopathological Correlation
    Das, M.
    Braunschweig, T.
    Muehlenbruch, G.
    Mahnken, A. H.
    Krings, T.
    Langer, S.
    Koeppel, T.
    Jacobs, M.
    Guenther, R. W.
    Mommertz, G.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 38 (01) : 14 - 19
  • [42] Computed tomography pulmonary angiography using high-pitch dual-source scanner technology
    Al Hassan, Donya A.
    Waheed, Khawaja B.
    El Sirafy, Mohamed N.
    Khattab, Mohamad A.
    Al-Hammadi, Hassan I.
    Ibrahim, Motassem F.
    Ibrahim, Motassem F.
    Arulanantham, Zechariah J.
    SAUDI MEDICAL JOURNAL, 2019, 40 (03) : 230 - 237
  • [43] The value of performing dual-source dual-energy computed tomography in analysis strategy for urinary mixed stone
    Wang, Xiao-Gang
    Fan, Bo
    Wang, Wei
    Jin, Yi-Ying
    Jin, Yan
    Yang, Zhi-Qiang
    Li, Xian-Cheng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2017, 10 (02): : 1519 - 1528
  • [44] Dual-source computed tomography protocols for the pediatric chest - scan optimization techniques
    Rapp, Jordan B.
    Ho-Fung, Victor M.
    Ramirez, Karen, I
    White, Ammie M.
    Otero, Hansel J.
    Biko, David M.
    PEDIATRIC RADIOLOGY, 2023, 53 (07) : 1248 - 1259
  • [45] Differential diagnosis of solitary pulmonary nodules with dual-source spiral computed tomography
    Shi, Zhitao
    Wang, Yanhui
    He, Xueqi
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2016, 12 (03) : 1750 - 1754
  • [46] Primary cardiac synovial sarcoma and dual-source cardiac computed tomography findings
    Xu, Yiming
    Xin, Chang
    Huang, Wei
    Shi, Yuzhen
    Bo, Genji
    ACTA CARDIOLOGICA, 2017, 72 (02) : 228 - 229
  • [47] Pre- and postsurgical diagnostics with dual-source computed tomography in cardiac surgery
    Nikolaou, K.
    Saam, T.
    Rist, C.
    Johnson, T.
    Vogt, F.
    Oberhoffer, M.
    Reichart, B.
    Reiser, M. F.
    Becker, C. R.
    RADIOLOGE, 2007, 47 (04): : 310 - 318
  • [48] Dual-Source Computed Tomography Angiography in Aortic Stenosis: Comparison with Transthoracic Echocardiography
    Yaakup, Nur Adura
    Phuah, Hooi Fang
    Aziz, Yang Faridah Abdul
    Abidin, Imran Zainal
    Sun, Zhonghua
    Ng, Kwan Hoong
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (05) : 749 - 755
  • [49] Dual-Source Computed Tomography Demonstrating Obstruction of Left Ventricular Outflow Tract
    Imagawa, Hiroshi
    Shikata, Fumiaki
    Kido, Teruhito
    Hosokawa, Kouhei
    Ryugo, Masahiro
    Mochizuki, Teruhito
    Kawachi, Kanji
    ANNALS OF THORACIC SURGERY, 2010, 90 (01): : 314 - 314
  • [50] Noninvasive Assessment of Coronary In-Stent Restenosis by Dual-Source Computed Tomography
    Pflederer, Tobias
    Marwan, Mohamed
    Renz, Alexandra
    Bachmann, Sven
    Ropers, Dieter
    Kuettner, Axel
    Anders, Katharina
    Bamberg, Fabian
    Daniel, Werner G.
    Achenbach, Stephan
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (06): : 812 - 817