Physical analysis of breast cancer using dual-source computed tomography

被引:1
|
作者
Kim, H. J. [1 ]
Lee, H. K. [2 ]
Cho, J. H. [3 ]
机构
[1] Soonchunhyang Univ Hosp, Dept Radiol, Puchon, South Korea
[2] Soonchunhyang Univ, Dept Comp Sci & Engn, Asan, South Korea
[3] Hallym Univ Grad Studies, Dept Int Radiol Sci, Seoul, South Korea
来源
关键词
Hounsfield Unit; breast cancer; physical characteristics; dual-source CT; IMAGE QUALITY; CT; COVERAGE; PHANTOM; VOLUME; MDCT;
D O I
10.1080/10420150.2014.977283
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study was aimed to analyze various physical characteristics of breast cancer using dual-source computed tomography (CT). A phantom study and a clinical trial were performed in order and a 64-multidetector CT device was used for the examinations. In the phantom study, single-source (SS) CT was set up with a conventional scanning condition that is usually applied for breast CT examination and implementation was done at tube voltage of 120 kVp. Dual-source CT acquired images by irradiating X-ray sources with fast switching between two kilovoltage settings (80 and 140 kVp). After scanning, Hounsfield Unit (HU) values and radiation doses in a region of interest were measured and analyzed. In the clinical trial, the HU values were measured and analyzed after single-source computed tomography (SSCT) and dual-source CT in patients diagnosed with breast cancer. Also, the tumor size measured by dual-source CT was compared with the actual tumor size. The phantom study determined that the tumor region was especially measured by dual-source CT, while nylon fiber and specks region were especially measured by SSCT. The radiation dose was high with dual-source CT. The clinical trial showed a higher HU value of cancerous regions when scanned by dual-source CT compared with SSCT.
引用
收藏
页码:994 / 1002
页数:9
相关论文
共 50 条
  • [1] T and N Staging of Gastric Cancer Using Dual-Source Computed Tomography
    Xie, Zhao-Yong
    Chai, Rui-Mei
    Ding, Guo-Cheng
    Liu, Yi
    Ren, Ke
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2018, 2018
  • [2] Subtotal Cor Triatriatum on Dual-Source Computed Tomography
    Sharma, Arun
    Biradar, Basavraj
    Malhi, Amarinder S.
    Kumar, Sanjeev
    ANNALS OF THORACIC SURGERY, 2019, 107 (03): : E213 - E213
  • [3] Analysis of Pulmonary Vein Antrums Motion with Cardiac Contraction Using Dual-Source Computed Tomography
    Bahig, Houda
    de Guise, Jacques
    Vu, Toni
    Chartrand-Lefebvre, Carl
    Blais, Danis
    Lebeau, Martin
    Nhu-Tram Nguyen
    Roberge, David
    CUREUS, 2016, 8 (07):
  • [4] Preoperative evaluation of coronary artery fistula using dual-source computed tomography
    Jiang, Yaowen
    Liu, Peng
    Cao, Yu
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 234 : 117 - 117
  • [5] Preoperative evaluation of coronary artery fistula using dual-source computed tomography
    Shi, Ke
    Gao, Hong-ling
    Yang, Zhi-gang
    Zhang, Qin
    Liu, Xi
    Guo, Ying-kun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 228 : 80 - 85
  • [6] Anatomical investigation of the sinus node artery using dual-source computed tomography
    Zhang, Long Jiang
    Wang, Yu Zhu
    Huang, Wei
    Chen, Peng
    Zhou, Chang Sheng
    Lu, Guang Ming
    CIRCULATION JOURNAL, 2008, 72 (10) : 1615 - 1620
  • [7] Visualization of anomalous coronary arteries on dual-source computed tomography
    G. J. de Jonge
    P. M. A. van Ooijen
    L. H. Piers
    R. Dikkers
    R. A. Tio
    T. P. Willems
    A. F. M. van den Heuvel
    F. Zijlstra
    M. Oudkerk
    European Radiology, 2008, 18 : 2425 - 2432
  • [8] Dynamic Myocardial Perfusion Imaging by Dual-Source Computed Tomography
    Parga Filho, Jose Rodrigues
    Lima Moraes Lima, Cintia Souza
    Lima, Felipe Gallego
    Jaques, Tiago da Silveira
    Rodrigues de Avila, Luiz Francisco
    Kalil Filho, Roberto
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2012, 98 (03) : E54 - E58
  • [9] Dual-source computed tomography in inpatients with atypical chest pain
    Arraiza, M.
    Arias, J.
    Broncano, J.
    Pueyo, J. C.
    Villanueva, A.
    Bastarrika, G.
    RADIOLOGIA, 2009, 51 (06): : 568 - 576
  • [10] Coronary revascularization treatment based on dual-source computed tomography
    Dikkers, R.
    Willems, T. P.
    Piers, L. H.
    de Jonge, G. J.
    Tio, R. A.
    van der Zaag-Loonen, H. J.
    van Ooijen, P. M. A.
    Zijlstra, F.
    Oudkerk, M.
    EUROPEAN RADIOLOGY, 2008, 18 (09) : 1800 - 1808