Topology and Control of a Split-Capacitor Four-Wire Current Source Inverter With Leakage Current Suppression Capability

被引:33
|
作者
Sun, Yao [1 ]
Liu, Yonglu [1 ]
Su, Mei [1 ]
Han, Hua [1 ]
Li, Xing [2 ]
Li, Xin [1 ]
机构
[1] Cent S Univ, Sch Informat Sci & Engn, Changsha 410083, Peoples R China
[2] Hunan Univ, Coll Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Control method; current source inverter (CSI); leakage current; transformer-less photovoltaic (PV) inverter; 3-PHASE; CONVERTERS; LINK;
D O I
10.1109/TPEL.2017.2771537
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a split-capacitor four-wire current source inverter, which is the dual of the split-capacitor four-wire voltage source inverter. Since the midpoint of the dc link is tied to the neutral point of ac filter capacitors, the common-mode voltage (CMV) is reduced significantly. Consequently, the leakage current issue is effectively addressed. The proposed circuit is cost-effective as no extra switch is added. This paper, first, establishes the equivalent common-mode circuit of the proposed inverter. The impact of the neutral line inductance on CMV is also analyzed. Then, a specific modulation is introduced to balance the dc-link voltages/currents. To achieve good input/output performance, a nonlinear control method is developed based on time-domain models. Finally, all the proposed methods and related theoretical analysis are verified by simulations and experimental results.
引用
收藏
页码:10803 / 10814
页数:12
相关论文
共 50 条
  • [31] Current Harmonics Cancellation in Three-Phase Four-Wire Systems by Using a Four-Branch Star Filtering Topology
    Rodriguez, Pedro
    Candela, J. Ignacio
    Luna, Alvaro
    Asiminoaei, Lucian
    Teodorescu, Remus
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (08) : 1939 - 1950
  • [32] Stability Analysis and Robust Control Method for LCL-Type Three-Phase Four-Wire Split Capacitor Inverter Considering Zero-Sequence Loop
    Yang, Longyue
    Cao, Tian
    Cai, Zhipeng
    Xia, Xuejing
    Jia, Chenxi
    Dong, Xinwei
    Zhang, Shuyuan
    ELECTRONICS, 2022, 11 (20)
  • [33] Analysis of hysteresis current control strategy of three-phase four-wire shunt APF
    Le, Jian
    Jiang, Qirong
    Han, Yingduo
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2006, 30 (17): : 70 - 75
  • [34] Transformerless Z-Source Four-Leg PV Inverter With Leakage Current Reduction
    Guo, Xiaoqiang
    Yang, Yong
    He, Ran
    Wang, Baocheng
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (05) : 4343 - 4352
  • [35] Leakage Current Reduction of Z-Source Four-Leg Inverter for Transformerless PVsystem
    Guo, Xiaoqiang
    He, Ran
    2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, : 380 - 383
  • [36] Highly-Reliable Switched-Boost Four-Leg Inverter With Leakage Current Suppression
    Do, Duc-Tri
    Truong, Ngoc-Anh
    Nguyen, Khai M.
    Duong, Truong-Duy
    IEEE ACCESS, 2024, 12 : 137054 - 137062
  • [37] Predictive Current Control of a New Four-Level Voltage Source Inverter
    Le, Hoang
    Dekka, Apparao
    Ronankit, Deepak
    Rodriguezt, Jose
    2022 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS, PEDES, 2022,
  • [38] Source Current Control Strategy of Active Power Filters for Unbalanced Load Compensation in Three-Phase Four-Wire Distribution Networks
    Wang, Lei
    Han, Xiaoqing
    Meng, Runquan
    Ren, Chunguang
    Wang, Qi
    Zhang, Baifu
    JOURNAL OF POWER ELECTRONICS, 2018, 18 (05) : 1545 - 1554
  • [39] A Transformerless Single-Phase Current Source Inverter Topology and Control for Photovoltaic Applications
    Cardoso, Jorge
    Vazquez, Nimrod
    Hernandez, Claudia
    Vaquero, Joaquin
    ENERGIES, 2018, 11 (08):
  • [40] Control for the Three-Phase Four-Wire Four-Leg APF Based on SVPWM and Average Current Method
    Li, Xiangshun
    Lu, Jianghua
    ACTIVE AND PASSIVE ELECTRONIC COMPONENTS, 2015, 2015