Long-term efficacy and safety of double balloon enteroscopy - prospective and retrospective data from a single center study

被引:16
|
作者
Maaser, Christian [1 ]
Schmedt, Andre [1 ]
Bokemeyer, Maja [1 ]
Kannengiesser, Klaus [1 ]
Ullerich, Hansjoerg [1 ]
Luegering, Andreas [1 ]
Domagk, Dirk [1 ]
Domschke, Wolfram [1 ]
Kucharzik, Torsten [1 ]
机构
[1] Univ Munster, Dept Internal Med B, Munster, Germany
关键词
Enteroscopy; inflammatory bowel disease; intestinal bleeding; SMALL-BOWEL DISEASE; CAPSULE ENDOSCOPY; DIAGNOSTIC YIELD; CLINICAL-EVALUATION; PULL ENTEROSCOPY; PUSH-ENTEROSCOPY; COMPLICATIONS; EXPERIENCE; DEPTH; MULTICENTER;
D O I
10.3109/00365521003710182
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective. Double balloon enteroscopy (DBE) has evolved as one of the most innovative and fast spreading endoscopic procedures in the last decade. With increasing experience of performing endoscopic procedures in the mid gut outside the operating room it is necessary to investigate the effectiveness of DBE regarding therapeutic consequences, long-term efficacy as well as safety. Material and methods. To address this we retrospectively analyzed all DBE performed over a period of 2 years at our department. Furthermore, in order to evaluate long-term effectiveness of DBE procedures we performed a follow-up analysis on all patients, whose DBE procedure was at least 6 months ago. In addition, 100 consecutive patients who underwent DBE were questioned regarding procedure associated complaints using a standardized questionnaire. Results. Retrospective analysis of all DBE procedures performed in our department before November 2006 (n = 545) revealed an overall diagnostic yield of 39.7% and a therapeutic yield of 31.1%. The overall number of major complications accounted to 0.9%. Follow-up analysis revealed a long-term effect of endoscopic interventions in more than 50%, while in those patients with an initially negative DBE long-term follow-up only revealed symptom explaining findings in 17% with the majority of the other patients being asymptomatic during follow-up. Regarding patient related complaints the prospective analysis showed that DBE procedures in general are well tolerated with the most common complaint being meteorism. Conclusions. DBE showed to be a relatively safe and well tolerated procedure. However, more sensitive algorithms are needed to enhance the therapeutic results.
引用
收藏
页码:992 / 999
页数:8
相关论文
共 50 条
  • [41] Efficacy and long-term outcomes of single-balloon enteroscopy-assisted treatment for biliary obstruction after choledochojejunostomy
    Weng, Hao
    Fan, Qing-quan
    Gu, Jun
    Weng, Ming-Zhe
    Zhang, Wen-Jie
    Xu, Lei-Ming
    Zhang, Yi
    Shu, Yi-Jun
    Wang, Xue-Feng
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2024, 38 (11): : 6282 - 6293
  • [42] Long-Term Outcomes After Single Balloon Enteroscopy in Patients With Obscure Gastrointestinal Bleeding
    Kushnir, Vladimir M.
    Tang, Michael
    Hollander, Thomas G.
    Hovis, Christine E.
    Early, Dayna S.
    Mullady, Daniel
    Murad, Faris
    Azar, Riad R.
    Jonnalagadda, Sreenivasa S.
    Edmundowicz, Steven A.
    Chen, Chien-Huan
    GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) : 251 - 251
  • [43] Efficacy of double balloon enteroscopy (DBE) initiated interventions and sensitivity of DBE regarding long term outcome - A follow-up study of a DBE examined single center patient cohort
    Maaser, Christian
    Bokemeyer, Maja
    Schmedt, Andre
    Ullerich, Hansjoerg
    Domagk, Dirk
    Heidemann, Jan
    Domschke, Wolfram
    Kucharzik, Torsten
    GASTROENTEROLOGY, 2007, 132 (04) : A498 - A499
  • [44] Long-term safety of fecal microbiota transplantation in Chinese children from 2013 to 2023: a single-center retrospective study
    Xiao, Pei
    Li, Youran
    Li, Xiaolu
    Ge, Ting
    Li, Dan
    Xu, Qiao
    Ruan, Yangming
    Xiao, Fangfei
    Xiao, Yongmei
    Zhang, Ting
    BMC MICROBIOLOGY, 2025, 25 (01):
  • [45] Long-term Safety and Efficacy of the Derivo Embolization Device in a Single-center Series
    Goertz, Lukas
    Zopfs, David
    Kottlors, Jonathan
    Borggrefe, Jan
    Pennig, Lenhard
    Schlamann, Marc
    Kabbasch, Christoph
    CLINICAL NEURORADIOLOGY, 2024, 34 (04) : 789 - 798
  • [46] Safety and long-term efficacy of endovascular treatment of small posterior communicating artery aneurysms by coiling with or without stent: A single center retrospective study
    Yao, Peng-Fei
    Yu, Ying
    Yang, Peng-Fei
    Xu, Yi
    Hong, Bo
    Zhao, Wen-Yuan
    Liu, Jian-Min
    Huang, Qing-Hai
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2013, 115 (12) : 2502 - 2507
  • [47] Long-Term Outcome of Patients Treated With Double Balloon Enteroscopy for Small Bowel Vascular Lesions
    Samaha, E.
    Rahmi, G.
    Landi, B.
    Lorenceau-Savale, C.
    Malamut, G.
    Canard, J. -M.
    Bloch, F.
    Jian, R.
    Chatellier, G.
    Cellier, C.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2012, 107 (02): : 240 - 246
  • [48] Long-term efficacy and safety analysis of single cycle of biosimilar rituximab in pemphigus: A retrospective study of 76 patients from India
    Shah, Bela J.
    Mistry, Deval
    Shah, Shikha R.
    DERMATOLOGIC THERAPY, 2022, 35 (09)
  • [49] Double-balloon enteroscopy in small bowel tumors: A Chinese single-center study
    Wen-Guo Chen
    Guo-Dong Shan
    Hong Zhang
    Lin Li
    Min Yue
    Zun Xiang
    Ying Cheng
    Chen-Jiao Wu
    Ying Fang
    Li-Hua Chen
    World Journal of Gastroenterology, 2013, (23) : 3665 - 3671
  • [50] Double-balloon enteroscopy in small bowel tumors: A Chinese single-center study
    Chen, Wen-Guo
    Shan, Guo-Dong
    Zhang, Hong
    Li, Lin
    Yue, Min
    Xiang, Zun
    Cheng, Ying
    Wu, Chen-Jiao
    Fang, Ying
    Chen, Li-Hua
    WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (23) : 3665 - 3671