Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study

被引:79
|
作者
Kalra, MK
Wittram, C
Maher, MM
Sharma, A
Avinash, GB
Karau, K
Toth, TL
Halpern, E
Saini, S
Shepard, JA
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] GE Co, Med Syst, Waukesha, WI USA
关键词
computed tomography (CT); radiation exposure; filters; radiographic; thorax; CT;
D O I
10.1148/radiol.2281020606
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Effect of noise reduction filters on chest computed tomographic (CT) images acquired with 50% radiation dose reduction was evaluated. Two sets of images were acquired with multi-detector row CT at standard (220-280 mA) and 50% reduced (110-140 mA) tube current at the level of the carina. After postprocessing with six noise reduction filters, images were compared with baseline standard-dose images for noise, sharpness, and contrast in lungs, mediastinum, and chest wall. Quantitative image noise was measured in descending thoracic aorta. Modulation transfer functions were calculated from CT images of 50-mum wire. Noise reduction filters reduced image noise on low-radiation-dose chest CT images, with some compromise in image sharpness and contrast assessed qualitatively, and slightly altered modulation transfer function at higher spatial frequencies. (C) RSNA, 2003.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 50 条
  • [1] Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters
    Kalra, MK
    Maher, MM
    Blake, MA
    Lucey, BC
    Karau, K
    Toth, TL
    Avinash, G
    Halpern, EF
    Saini, S
    [J]. RADIOLOGY, 2004, 232 (03) : 791 - 797
  • [2] Lesion detection on reduced radiation dose CT images processed with noise reduction filters
    Kalra, MK
    Maher, MM
    Lucey, BC
    Blake, MA
    Karau, K
    Saini, S
    [J]. RADIOLOGY, 2002, 225 : 645 - 646
  • [3] Low-dose CT of the abdomen: Evaluation of image improvement with use of noise reduction filters - Pilot study
    Kalra, MK
    Maher, MM
    Sahani, DV
    Blake, MA
    Hahn, PF
    Avinash, GB
    Toth, TL
    Halpern, E
    Saini, S
    [J]. RADIOLOGY, 2003, 228 (01) : 251 - 256
  • [4] Local noise estimation in low-dose chest CT images
    J. Padgett
    A. M. Biancardi
    C. I. Henschke
    D. Yankelevitz
    A. P. Reeves
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 221 - 229
  • [5] Local noise estimation in low-dose chest CT images
    Padgett, J.
    Biancardi, A. M.
    Henschke, C. I.
    Yankelevitz, D.
    Reeves, A. P.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (02) : 221 - 229
  • [6] Radiation dose reduction for chest CT with non-linear adaptive filters
    Singh, Sarabjeet
    Digumarthy, Subba R.
    Back, Anni
    Shepard, Jo-anne O.
    Kalra, Mannudeep K.
    [J]. ACTA RADIOLOGICA, 2013, 54 (02) : 169 - 174
  • [7] Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot Study
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Gilman, Matthew D.
    Hsieh, Jiang
    Pien, Homer H.
    Digumarthy, Subba R.
    Shepard, Jo-Anne O.
    [J]. RADIOLOGY, 2011, 259 (02) : 565 - 573
  • [8] Comparison of standard- and low-radiation-dose CT for quantification of emphysema
    Gierada, David S.
    Pilgram, Thomas K.
    Whiting, Bruce R.
    Hong, Cheng
    Bierhals, Andrew J.
    Kim, Jin Hwan
    Bae, Kyongtae T.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) : 42 - 47
  • [9] Radiation dose reduction in chest CT: A review
    Kubo, Takeshi
    Lin, Pei-Jan Paul
    Stiller, Wolfram
    Takahashi, Masaya
    Kauczor, Hans-Ulrich
    Ohno, Yoshiharu
    Hatabu, Hiroto
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (02) : 335 - 343
  • [10] Deep Learning Algorithm for Simultaneous Noise Reduction and Edge Sharpening in Low-Dose CT Images A Pilot Study Using Lumbar Spine CT
    Yeoh, Hyunjung
    Hong, Sung Hwan
    Ahn, Chulkyun
    Choi, Ja -Young
    Chae, Hee-Dong
    Yoo, Hye Jin
    Kim, Jong Hyo
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (11) : 1850 - 1857