The three-temperature frost-free refrigerator is popular in China currently, which adopts a single evaporator and separate air ducts to distribute cold air into all compartments, i.e., the fresh food compartment (FFC), the variable temperature compartment (VTC), and the freezer compartment (FZC). Two identical refrigerators with cyclopentane insulation are comparatively studied in this article, one with vacuum insulation panels (VIPs) in two sidewalls and the other without. Results show that VIPs reduce the steady-state energy consumption of the refrigerator by 12.4% due to smaller average power input and longer compressor-off duration. The decrease in average power input originates from a shorter FFC-damper-on duration since VIPs reduce its thermal load. However, the FFC average temperature rises unexpectedly with shorter damper-on and longer damper-off durations, and induces thermal load transfer from FFC to FZC through the mixing of return air in the evaporator chamber. Consequently, FZC-only duration increases and compensates for the decrease in FFC-damper-on duration, resulting in an overall similar compressor-on duration. Simulation results of the heat transfer process through the evaporator are also provided in both cases to obtain a full view of the thermal load transfer process.
引用
收藏
页数:14
相关论文
共 2 条
  • [1] Comparison of independent and synchronous opening control strategies of two air-dampers in three-temperature frost-free refrigerator
    Zhang, Zhenya
    Huang, Dong
    Shi, Lihua
    Chi, Lihua
    APPLIED THERMAL ENGINEERING, 2018, 128 : 127 - 133
  • [2] Distributed heaters to reduce temperature rise in freezing cabinet during defrost process and its overall energy effect for a frost-free refrigerator
    Zhao, Rijing
    Huang, Dong
    Peng, Xueyuan
    Yang, Hao
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 99 : 186 - 193