Distributed heaters to reduce temperature rise in freezing cabinet during defrost process and its overall energy effect for a frost-free refrigerator

被引:19
|
作者
Zhao, Rijing [1 ]
Huang, Dong [1 ]
Peng, Xueyuan [1 ]
Yang, Hao [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Temperature rise; Energy effect; Defrost cycle; Frost-free refrigerator; CONTROL STRATEGIES; THERMAL STORAGE; AIR; PERFORMANCE; EXCHANGER; SYSTEM; EVAPORATOR;
D O I
10.1016/j.ijrefrig.2018.12.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
In most frost-free refrigerators with a bottom defrost heater (BDH) for the evaporator, the mismatch between bottom-up dissipation of defrost heat and distributed coverage of frost extends defrost duration, which promotes defrost heat intrusion into freezing cabinets (FCs) and dominates temperature rise there. The objective of this article is to propose a method of reducing FC-temperature rise during defrost cycles for frost-free refrigerators. Based on the idea of better matching defrost heat dissipation and frost coverage, distributed defrost heaters (DDHs) were utilized by adding an extra heater (60 W) in the middle of the evaporator besides the original bottom one (180 W). Then, defrost performance was compared experimentally between BDH and DDHs cycles. Results show that DDHs resulted in 1.1 degrees C decline in FC-temperature rise with 3.3 min reduction in defrost duration. Moreover, the extra heater power hardly raised the overall energy consumption of the refrigerator, because the lower FC temperature after defrost reduced the energy consumption in the following recovery cycle, which compensated for the increase in the defrost cycle. Therefore, the utilization of DDHs is an efficient method in improving defrost performance and food storage quality. (C) 2018 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:186 / 193
页数:8
相关论文
共 5 条
  • [1] Effect of defrost heat leakage on freezer temperature rise during periodical defrost cycles in a frost-free refrigerator-freezer with an electric defrost heater
    Zhao, Rijing
    Huang, Dong
    Zhang, Zhenya
    Leng, Yongqiang
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (01) : 211 - 217
  • [2] Experimental investigation for dynamic characteristics of defrosting process and effect on freezer compartment temperature in domestic frost-free refrigerator
    Tang, Xueqiang
    Huang, Dong
    Gong, Qinqin
    Bai, Lianshe
    Wei, Bangfu
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2014, 48 (11): : 81 - 85
  • [3] Analysis of temperature rapid rise phenomenon during damper-off cycle in side-by-side frost-free refrigerator
    Yang, Yikun
    Huang, Dong
    Zhao, Rijing
    Guo, Wenhua
    Wei, Xinghua
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 133 : 201 - 213
  • [4] Reducing cabinet temperature rise during electric heater defrosting of frost-free refrigerators by using a special fan cover to block heat infiltration
    Zhao, Rijing
    Huang, Dong
    Peng, Xueyuan
    Yang, Hao
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (10) : 1505 - 1513
  • [5] Effect of Vacuum Insulation Panels on Energy Consumption and Thermal Load Transfer between Compartments in a Three-Temperature Frost-Free Refrigerator
    Zhao, Rijing
    Qiao, Lin
    Gao, Zijian
    Huang, Dong
    ENERGIES, 2020, 13 (07)