Optimization of Cellular analysis of Synovial Fluids by optical microscopy and automated count using the Sysmex XN Body Fluid Mode

被引:21
|
作者
Seghezzi, Michela [1 ]
Buoro, Sabrina [1 ]
Manenti, Barbara [1 ]
Mecca, Tommaso [1 ]
Ferrari, Roberto [2 ]
Zappala, Giorgio [2 ]
Castelli, Claudio Carlo [2 ]
Balboni, Fiamma [3 ]
Pezzati, Paola [4 ]
Ottomano, Cosimo [5 ]
Lippi, Giuseppe [6 ]
机构
[1] Papa Giovanni XXIII Hosp, Clin Chem Lab, Piazza OMS,1, I-24127 Bergamo, Italy
[2] Hosp Papa Giovanni XXIII, Orthoped & Traumatol Unit, Bergamo, Italy
[3] IFCA, Clin Chem Lab, Florence, Italy
[4] Univ Florence, Clin Chem Lab, Hosp Careggi Firenze, I-50121 Florence, Italy
[5] Synlab, Monza, Italy
[6] Univ Verona, Clin Biochem Sect, Verona, Italy
关键词
Synovial fluid; Optical; Microscopy; XN; Sysmex; Body Fluids; REFLEX TESTING RULES; ASCITIC FLUIDS; BLOOD-CELLS; PERFORMANCE;
D O I
10.1016/j.cca.2016.08.018
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: This study was planned to assess the impact of pre-treating synovial fluid (SF) samples with hyaluronidase (HY), defining the best procedure for optical microscopy (OM) analysis and evaluating the performance of Sysmex XN-9000 Body Fluid module (XN-BF). Methods: The cell count by OM was carried out both with and without HY pre-treatment, and using 3 different types of staining reagents. The evaluation of XN-BF included data comparison with OM (100 SFs), carryover, Limit of Blank (LoB), Limit of Detection (LoD), Limit of Quantitation (LoQ) and linearity. Results: Unlike cell count in Burker's chamber and staining with Stromatol, pre-treatment with HY and staining with Methylene Blue and Turk's promoted cell clustering. The SF samples pre-treated with HY displayed excellent morphological quality, contrary to samples without HY pre-treatment. Excellent correlation was found between total cells counting with both OM and XN-BF. Satisfactory agreement was also observed between polymorphonuclear neutrophils compared to XN-BF parameter, whereas mononuclear cell count on XN-BF had suboptimal agreement with OM. The carryover was negligible. The LoB, LoD, LoQ and linearity were excellent. Conclusion: XN-BF displays excellent performance, which makes it a reliable and practical alternative to OM for SF samples analysis in clinical laboratories. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 24 条
  • [21] Comparison between "body fluid" mode of two hematology analyzers and the microscopy method for cellular analysis of the cerebrospinal fluid
    Seghezzi, Michela
    Mecca, Tommaso
    Dominoni, Paola
    Lochis, Eleonora
    Saleri, Cheren
    Manenti, Barbara
    Crippa, Alberto
    Buoro, Sabrina
    BIOCHIMICA CLINICA, 2016, 40 (04) : 322 - 327
  • [22] A comparison of the analysis of 3 types of body fluids using the XN-350 hematology analyzer versus light microscopy assessment
    Lee, Jiwon
    Cho, Younggeun
    Kim, Han-Sung
    Kang, Hee Jung
    Kim, Miyoung
    Lee, Young Kyung
    MEDICINE, 2021, 100 (11) : E24852
  • [23] Validation of reflex testing rules and establishment of a new workflow for body fluid cell analysis using a Sysmex XN-550 automatic hematology analyzer
    Cho, Y-U
    You, E.
    Jang, S.
    Park, C-J
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (03) : 258 - 267
  • [24] Multi-site verification and performance of body fluids in-between Horiba Medical Yumizen h2500 with Sysmex XN-10 automated hematology analyzers and manual microscopy for morphology assessment
    Hege, M. L.
    CLINICAL CHEMISTRY, 2024, 70 : I59 - I59