Experimental behavior of steel beam to CFT column connections

被引:125
|
作者
Elremaily, A [1 ]
Azizinamini, A [1 ]
机构
[1] Univ Nebraska, Lincoln, NE 68588 USA
基金
美国国家科学基金会;
关键词
concrete filled tube (CFT) columns; failure mode; beam-column subassembly; connection strength;
D O I
10.1016/S0143-974X(01)00025-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Available literature has indicated that the through beam connection detail is an ideal rigid connection for attaching steel beams to concrete filled tube (CFT) columns. In this research program, a combination of analytical and experimental studies was conducted to comprehend the behavior of this detail and develop the accompanying design provisions. The experimental research program is presented in this paper. Seven two-thirds scale connection specimens were tested. Each test specimen consisted of a CFT column and a steel beam passed through the column to represent an interior joint in a building. The specimens were designed such that possible failure modes and the connection strength could be identified. Based on test results, possible modes of failure for a beam-column subassembly are identified as column failure, beam failure, and joint shear failure. The joint shear strength is determined based on the results of two test specimens that failed by joint shear. The experimental results presented in this paper provided the basis for the development of the design model, which is described in another paper. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1099 / 1119
页数:21
相关论文
共 50 条
  • [21] Moment resistance of steel I-beam to CFT column connections with composite slab
    Mulia, O
    Chiew, SP
    Lie, ST
    TUBULAR STRUCTURES IX, 2001, : 543 - 552
  • [22] Experimental seismic behavior of RC special-shaped column to steel beam connections with steel jacket
    Hao, Jiashu
    Ren, Qingying
    Li, Xingqian
    Zhang, Xizhi
    Ding, Yongjun
    Zhang, Shaohua
    STEEL AND COMPOSITE STRUCTURES, 2022, 45 (01): : 101 - 118
  • [23] Seismic behavior of steel beam and reinforced concrete column connections
    Cheng, CT
    Chen, CC
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (05) : 587 - 606
  • [24] Study on cyclic behavior of concrete column steel beam connections
    Paudel, Madhu
    Arunkumar, C.
    Rajkumar, R.
    INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2024, 9 (08)
  • [25] Experimental study on the weld fracture behavior of high strength steel beam-to-column connections
    Liu X.-Y.
    Wang Y.-Q.
    Shi Y.-J.
    Tan Q.-H.
    Wang, Yuan-Qing (wang-yq@mail.tsinghua.edu.cn), 2018, Tsinghua University (35): : 54 - 64
  • [26] Experimental behavior of screwed beam-to-column connections in cold-formed steel frames
    Maali, Mahyar
    Sagiroglu, Merve
    Solak, M. Semih
    ARABIAN JOURNAL OF GEOSCIENCES, 2018, 11 (09)
  • [27] Experimental behavior of screwed beam-to-column connections in cold-formed steel frames
    Mahyar Maali
    Merve Sagiroglu
    M. Semih Solak
    Arabian Journal of Geosciences, 2018, 11
  • [28] Seismic behavior of encased CFT column base connections
    Li, Xian
    Zhou, Tao
    Li, Jian
    Kuang, Xiao-Bo
    Zhao, Yu-Wei
    ENGINEERING STRUCTURES, 2019, 182 : 363 - 378
  • [29] Shear behavior of exterior reinforced concrete column-steel beam beam-column connections
    Shen, Hong-Xia
    Gu, Qiang
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (SUPPL. 1): : 154 - 161
  • [30] Analytical and Experimental Investigation of I Beam-to-CFT Column Connections under Monotonic Loading
    Abdollahzadeh, G. R.
    Gharavi, S. Yapang
    Beigy, M. Hoseinali
    INTERNATIONAL JOURNAL OF ENGINEERING, 2014, 27 (02): : 293 - 305