Experimental behavior of steel beam to CFT column connections

被引:125
|
作者
Elremaily, A [1 ]
Azizinamini, A [1 ]
机构
[1] Univ Nebraska, Lincoln, NE 68588 USA
基金
美国国家科学基金会;
关键词
concrete filled tube (CFT) columns; failure mode; beam-column subassembly; connection strength;
D O I
10.1016/S0143-974X(01)00025-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Available literature has indicated that the through beam connection detail is an ideal rigid connection for attaching steel beams to concrete filled tube (CFT) columns. In this research program, a combination of analytical and experimental studies was conducted to comprehend the behavior of this detail and develop the accompanying design provisions. The experimental research program is presented in this paper. Seven two-thirds scale connection specimens were tested. Each test specimen consisted of a CFT column and a steel beam passed through the column to represent an interior joint in a building. The specimens were designed such that possible failure modes and the connection strength could be identified. Based on test results, possible modes of failure for a beam-column subassembly are identified as column failure, beam failure, and joint shear failure. The joint shear strength is determined based on the results of two test specimens that failed by joint shear. The experimental results presented in this paper provided the basis for the development of the design model, which is described in another paper. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1099 / 1119
页数:21
相关论文
共 50 条
  • [1] Behavior of steel beam to circular CFT column connections
    Chen, CC
    Lo, SH
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 927 - 933
  • [2] Numerical and experimental study on the behavior of drilled flange steel beam to CFT column connections
    Parvari, Ali
    Zahrai, Seyed Mehdi
    Mirhosseini, S. Mohammad
    Zeighami, Ehsanollah
    STRUCTURES, 2020, 28 : 726 - 740
  • [3] Cyclic Behavior of Steel Beam to CFT Column Connections with Gusset Plates
    Wang, Peng
    Wang, Zhan
    Pan, Jianrong
    Zheng, Yanjun
    Liu, Deming
    ADVANCES IN CIVIL ENGINEERING, 2019, 2019
  • [4] Experimental study of steel I-beam to CFT column connections
    Chiew, SP
    Dai, CW
    ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, 1999, : 291 - 303
  • [5] Experimental investigation of CFT column to steel beam connections under cyclic loading
    Sheet, Ikhlas S.
    Gunasekaran, Umarani
    MacRae, Gregory A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 86 : 167 - 182
  • [6] The Effects of Internal and External Stiffeners on Hysteretic Behavior of Steel Beam to CFT Column Connections
    Razzaghi, M. S.
    Esfandyary, R.
    Nateghi, F. A.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2014, 27 (07): : 1005 - 1014
  • [7] Elasto plastic behavior of steel beam to square concrete filled steel tube (CFT) column connections
    Fukumoto, T
    Morita, K
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 565 - 572
  • [8] A parametric investigation on the hysteretic behaviour of CFT column to steel beam connections
    Esfandyary, R.
    Razzaghi, M. S.
    Eslami, A.
    STRUCTURAL ENGINEERING AND MECHANICS, 2015, 55 (01) : 205 - 228
  • [9] Moment resistance of steel I-beam to CFT column connections
    Chiew, SP
    Lie, ST
    Dai, CW
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2001, 127 (10): : 1164 - 1172
  • [10] Effect of stiffener details on behavior of CFT column-to-beam connections
    Kim, Young-Ju
    Shin, Kyung-Jae
    Kim, Wha-Jung
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2008, 8 (02) : 119 - 133