Characterizing the surface crack size by magnetic flux leakage testing

被引:0
|
作者
Li, LM [1 ]
Zhang, JJ [1 ]
机构
[1] Tsing Hua Univ, Dept Engn Mech, NDT Lab, Beijing 100084, Peoples R China
关键词
magnetic flux leakage testing (MFL); depth evaluation; finite element method;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The work of this paper is mainly on evaluation the surface crack of different depth and width just like natural defects. First, the effect of slot width to the leakage flux is carefully studied using finite element method(FEM.). Then the ''Width model" about the influence of slot width is developed. Base on the research of the influence of width, a new quantitative testing method is advanced in order to size the surface cracks with different width and depth. The core of the new method is the consideration of the influence of width. The results of FEM. and the experiment show that: the characterizing result is very good after the correction of Byp-p (y component peak to peak value)by slot's width.
引用
收藏
页码:793 / 798
页数:6
相关论文
共 50 条
  • [41] The Application of Magnetic Shielding Effect in Drill Pipe Magnetic Leakage Flux Testing
    Ma Yilai
    Lin Li
    Jiang Kaiwen
    Zhao Xulin
    2013 FIFTH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2013), 2013, : 1135 - 1138
  • [42] Multifrequency AC Magnetic Flux Leakage Testing for the Detection of Surface and Backside Defects in Thick Steel Plates
    Wang, Gang
    Xiao, Qi
    Gao, Zihao
    Li, Wenhui
    Jia, Liang
    Liang, Ce
    Yu, Xue
    IEEE MAGNETICS LETTERS, 2022, 13
  • [43] Optimal Frequency of AC Magnetic Flux Leakage Testing for Detecting Defect Size and Orientation in Thick Steel Plates
    Wang, Gang
    Xiao, Qi
    Guo, Minghui
    Yang, Jinqi
    IEEE TRANSACTIONS ON MAGNETICS, 2021, 57 (09)
  • [44] Crack Detection in Ferromagnetic Metal by Low Frequency Magnetic Flux Leakage Technique
    Liu, Zexu
    Shen, Changyu
    Lou, Weimin
    Shentu, Fengying
    Zhu, Zhouhong
    Li, Guanghai
    Lu, Xinyuan
    2017 16TH INTERNATIONAL CONFERENCE ON OPTICAL COMMUNICATIONS & NETWORKS (ICOCN 2017), 2017,
  • [45] A sensor measuring the Fourier coefficients of the magnetic flux density for pipe crack detection using the magnetic flux leakage method
    Nara, T.
    Takanashi, Y.
    Mizuide, M.
    JOURNAL OF APPLIED PHYSICS, 2011, 109 (07)
  • [46] Axial Magnetic Field Sensing for Pulsed Magnetic Flux Leakage Hairline Crack Detection and Quantification
    Okolo, Chukwunonso K.
    Meydan, Turgut
    2017 IEEE SENSORS, 2017, : 349 - 351
  • [47] A Method for Detecting Surface Defects in Railhead by Magnetic Flux Leakage
    Jia, Yinliang
    Zhang, Shicheng
    Wang, Ping
    Ji, Kailun
    APPLIED SCIENCES-BASEL, 2021, 11 (20):
  • [48] MODEL FOR DIAGNOSIS OF SURFACE CRACKS BY MAGNETIC FLUX LEAKAGE.
    Francis, P.H.
    Moseley, Tricia K.
    British Journal of Non-Destructive Testing, 1979, 21 (02): : 79 - 83
  • [49] FAR SURFACE SENSITIVITY OF MAGNETIC-FLUX LEAKAGE INSPECTION
    PROCTOR, NB
    MATERIALS EVALUATION, 1983, 41 (10) : S25 - S25
  • [50] A Permeability-Measuring Magnetic Flux Leakage Method for Inner Surface Crack in Thick-Walled Steel Pipe
    Zhiyang Deng
    Yanhua Sun
    Yihua Kang
    Kai Song
    Rongbiao Wang
    Journal of Nondestructive Evaluation, 2017, 36