Magnetic particle detection in unshielded environment using orthogonal fluxgate gradiometer

被引:6
|
作者
Elrefai, Ahmed L. [1 ]
Sasada, Ichiro [1 ]
机构
[1] Kyushu Univ, Appl Sci Elect & Mat, Kasuga, Fukuoka 816, Japan
关键词
CONTAMINANT DETECTION SYSTEM; METALLIC CONTAMINANT; SQUIDS;
D O I
10.1063/1.4913720
中图分类号
O59 [应用物理学];
学科分类号
摘要
A new detection system for magnetic particles, which can operate in an unshielded environment, is developed using a fundamental mode orthogonal fluxgate gradiometer. The proposed detection system offers the advantages of cost, size, and weight reduction as compared to contamination detection systems using superconducting quantum interference device sensor. The detection system can be used to detect metallic contamination in foods or lithium ion battery production lines. The system has been investigated numerically to optimize various design parameters of the system. Experimental setup has been developed to evaluate some of the numerically predicted results. Steel balls were successfully detected down to the diameter of 50 mu m. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Magnetorelaxometry of magnetic nanoparticles in magnetically unshielded environment utilizing a differential fluxgate arrangement -: art. no. 106102
    Ludwig, F
    Mäuselein, S
    Heim, E
    Schilling, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (10): : 1 - 3
  • [32] High-Tc second-order gradiometer for magnetocardiography in an unshielded environment
    Kouznetsov, KA
    Borgmann, J
    Clarke, J
    APPLIED PHYSICS LETTERS, 1999, 75 (13) : 1979 - 1981
  • [33] A high-Tc second-order gradiometer for use in an unshielded environment
    Broussov, PP
    Romans, EJ
    Carr, C
    Donaldson, GB
    Pegrum, CM
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 837 - 840
  • [34] An orthogonal fluxgate-type magnetic microsensor
    Zorlu, O
    Kejik, P
    Vincent, F
    Popovic, RS
    MEMS 2006: 19TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2006, : 646 - 649
  • [35] Second-order, high-temperature superconducting gradiometer for magnetocardiography in unshielded environment
    Zhang, Y
    Panaitov, G
    Wang, SG
    Wolters, N
    Otto, R
    Schubert, J
    Zander, W
    Krause, HJ
    Soltner, H
    Bousack, H
    Braginski, AI
    APPLIED PHYSICS LETTERS, 2000, 76 (07) : 906 - 908
  • [36] Crack Detection Using Fluxgate Magnetic Field Sensor
    Izgi, T.
    Goktepe, M.
    Bayri, N.
    Kolat, V. S.
    Atalay, S.
    ACTA PHYSICA POLONICA A, 2014, 125 (02) : 211 - 213
  • [37] Magnetic markers detection using PCB fluxgate array
    Janosek, M.
    Ripka, P.
    Platil, A.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (07)
  • [38] Compact fluxgate magnetic full-tensor gradiometer with spherical feedback coil
    Sui, Yangyi
    Li, Guang
    Wang, Shilong
    Lin, Jun
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (01):
  • [39] Flip-chip-type high-Tc gradiometer for biomagnetic measurements in unshielded environment
    Yongjun Tian
    Tiansheng Wang
    Ke Chen
    Lie Chen
    Dongning Zheng
    Hanhong Qi
    Sven Linzen
    Frank Schmidl
    Paul Seidel
    Science in China Series A: Mathematics, 2000, 43 : 82 - 87
  • [40] Reduction of magnetic noise limits of orthogonal fluxgate sensor
    Dressler, Michal
    Janosek, Michal
    Butta, Mattia
    AIP ADVANCES, 2021, 11 (01)