Dynamic phasor modeling of the doubly-fed induction generator under unbalanced conditions

被引:22
|
作者
Demiray, T. [1 ]
Milano, F. [2 ]
Andersson, G. [1 ]
机构
[1] ETH, Power Syst Lab, Zurich, Switzerland
[2] Univ Castilla La Mancha, Dept Elect Engn, E-13071 Ciudad Real, Spain
关键词
dynamic phasor approach; wind turbine; doubly-fed induction generator; unbalanced condition; voltage sag;
D O I
10.1109/PCT.2007.4538460
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes the use of the dynamic phasor approach for studying the behavior of doubly-fed induction generators during faults and unbalanced conditions. The dynamic phasor approach provides more accurate models than the quasi-stationary ones and, at the same time, is computationally more efficient than detailed EWTP models. Two contingencies are taken as examples to study the wind turbine behavior: balanced and unbalanced voltage sags. Results are compared with standard electromechanical and electromagnetical models.
引用
收藏
页码:1049 / +
页数:2
相关论文
共 50 条
  • [31] Optimization Strategy of Virtual Synchronous Generator Control for Doubly-fed Induction Generator in Unbalanced Power Grid
    Sun J.
    Jiang T.
    Wang Y.
    Sun D.
    Ye S.
    Duan H.
    [J]. Sun, Dan (sundan@zju.edu.cn), 1600, Automation of Electric Power Systems Press (44): : 135 - 144
  • [32] Smoothing Control of Doubly-Fed Induction Generator Wind Turbine under Different Wind Conditions
    Chang, Yuan
    Fu, Kunkun
    [J]. PROCEEDINGS OF THE 2015 ASIA-PACIFIC ENERGY EQUIPMENT ENGINEERING RESEARCH CONFERENCE (AP3ER 2015), 2015, 9 : 35 - 38
  • [33] Control Strategy of Stand-Alone Brushless Doubly-Fed Induction Generator System under Unbalanced Loads
    Jiang Y.
    Cheng M.
    Wang Q.
    Wei X.
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2018, 33 (05): : 998 - 1006
  • [34] Transient Responses of the Doubly-Fed Induction Generator Wind Turbine under Grid Fault Conditions
    Phan, T. T.
    Nguyen, V. L.
    Hossain, M. J.
    To, A. N.
    Tran, H. T.
    Phan, T. N.
    [J]. 2016 INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND APPLICATIONS (ACOMP), 2016, : 97 - 104
  • [35] Dynamic behavior of the excitation circuit of a doubly-fed induction generator under a symmetrical voltage drop
    Ouyang, Jinxin
    Xiong, Xiaofu
    [J]. RENEWABLE ENERGY, 2014, 71 : 629 - 638
  • [36] Passive Control for Brushless Doubly-Fed Reluctance Generator Under Unbalanced Grid Voltages
    Yang, Xiaoliang
    Qin, Yixuan
    Bai, Jiajun
    Zhan, Jihao
    Li, Yihao
    Hao, Suya
    [J]. IEEE ACCESS, 2024, 12 : 93739 - 93752
  • [37] Dynamic Behaviour of a Wind Energy Conversion System Including Doubly-Fed Induction Generator in Fault Conditions
    Giaourakis, Dimitrios G.
    Safacas, Athanasios
    Tsotoulidis, Savvas
    [J]. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2012, 2 (02): : 227 - 235
  • [38] Flexible power control for rotor-side converter of doubly-fed induction generator under unbalanced voltage condition
    Ma J.
    Liu Q.
    Wu J.
    Sun F.
    Wang Y.
    Shen Y.
    Zhou N.
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (02): : 196 - 203
  • [39] Effect of Static or Dynamic Eccentricities on the Unbalanced Magnetic Pull in Doubly-Fed Induction Machines
    Moisson-Franckhauser, Nicolas
    Lugand, Thomas
    Schwery, Alexander
    Garbuio, Lauric
    [J]. 2017 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES, DRIVES AND POWER SYSTEMS (ELMA), 2017, : 383 - 388
  • [40] Dynamic power flow in wind turbine systems with doubly-fed induction generator
    Dirscherl, Christian
    Hackl, Christoph M.
    [J]. 2016 IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON), 2016,