Bioanalytical method development, validation and quantification of flupirtine maleate in rat plasma by liquid chromatography-tandem mass spectrometry

被引:1
|
作者
Kandasamy, Karthikeyan [1 ]
Gowdra, Vasantharaju Surenahalli [1 ]
Nammalvar, Hariprabhu [2 ]
Govindarajan, Arul Kumaran Kottur S. [2 ]
机构
[1] Manipal Univ, Manipal Coll Pharmaceut Sci, Dept Pharmaceut Qual Assurance, Manipal 576104, Karnataka, India
[2] KMCH Coll Pharm, Dept Pharmaceut, Kalapatti Coimbatore, India
来源
ARZNEIMITTELFORSCHUNG-DRUG RESEARCH | 2011年 / 61卷 / 12期
关键词
Electrospray ionization; Flupirtine; HPLC; Mass detection; Rat plasma; Validation; EFFICACY;
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A simple, highly sensitive, precise and accurate high-performance liquid chromatographic (LCMSMS) method with mass detection was developed and validated for the rapid quantification of flupirtine (CAS 75507-68-5) in rat plasma samples. The chromatographic separation was achieved with a reverse phase column (4.6 x 50 mm, 5 mu m) and the mobile phase consisted of cyanomethane and 5 mM ammonium formate buffer pH 4.5 (70:30 v/v) as eluent, at a flow rate of 0.6 mL/min. Labetalol (CAS 36894-69-6) was used as an internal standard. The effluence was ionized by positive electrospray ionization and measured by mass spectrometry. The retention times of fiupirtine and labetalol were found to be 2.16 and 1.66 min respectively. The calibration curve was linear (r(2) > or = 0.99) ranging from 0.98 to 1000 ng/ml and the lower limit of quantification was 0.98 ng/mL. Inter-day and Intra-day precision were lower than 5% (CV) and accuracy ranged from 90 to 110% in terms of percent accuracy. Mean extraction recovery was found to be above 86.5%. The method was successfully applied for evaluation of the pharmacokinetic profile of flupirtine in male Sprague-Dawley rats and validated for excellent selectivity, accuracy, precision, recovery and stability.
引用
收藏
页码:693 / 699
页数:7
相关论文
共 50 条
  • [31] Development and validation of bioanalytical liquid chromatography-tandem mass spectrometry method for the estimation of pentoxifylline in human plasma: Application for a comparative pharmacokinetic study
    Dodda, Sireesha
    Makula, Ajitha
    Polagani, Srinivasa R.
    Kandhagatla, Raj N.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2019, 25 (04) : 372 - 380
  • [32] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of febuxostat in human plasma
    Wang, Haidong
    Deng, Pan
    Chen, Xiaoyan
    Guo, Lixia
    Zhong, Dafang
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (01) : 34 - 38
  • [33] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of goserelin in rabbit plasma
    Kim, Min Kyung
    Lee, Tae Ho
    Suh, Joon Hyuk
    Eom, Han Young
    Min, Jung Won
    Yeom, Hyesun
    Kim, Unyong
    Jung, Hyung Joon
    Cha, Kyung Hoi
    Choi, Yong Seok
    Youm, Jeong-Rok
    Han, Sang Beom
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (24): : 2235 - 2242
  • [34] Bioanalytical Method for Estimation of Nitrofurantoin in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry
    Tamilarasi, Ganesan Padmini
    Manikandan, Krishnan
    Solomon, Viswas Raja
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (08) : 1108 - 1120
  • [35] Development and validation of a high-performance liquid chromatography-tandem mass spectrometric method for quantification of daunorubicin in rat plasma
    Yang, Yuhui
    TALANTA, 2007, 71 (02) : 596 - 604
  • [36] Quantification of methylone and metabolites in rat and human plasma by liquid chromatography-tandem mass spectrometry
    Kayla N. Ellefsen
    Marta Concheiro
    Masaki Suzuki
    Kenner C. Rice
    Joshua S. Elmore
    Michael H. Baumann
    Marilyn A. Huestis
    Forensic Toxicology, 2015, 33 : 202 - 212
  • [37] Quantification of methylone and metabolites in rat and human plasma by liquid chromatography-tandem mass spectrometry
    Ellefsen, Kayla N.
    Concheiro, Marta
    Suzuki, Masaki
    Rice, Kenner C.
    Elmore, Joshua S.
    Baumann, Michael H.
    Huestis, Marilyn A.
    FORENSIC TOXICOLOGY, 2015, 33 (02) : 202 - 212
  • [38] Liquid chromatography-tandem mass spectrometry method for determination of thiencynonate in rat plasma
    Xu, yanxia
    Kou, yuying
    Ruan, jinxiu
    Zhang, zhenqing
    Kiu, keliang
    Xue, ming
    ACTA PHARMACOLOGICA SINICA, 2006, 27 : 212 - 212
  • [39] Development of a sensitive liquid chromatography-tandem mass spectrometry method for quantification of human plasma arginine vasopressin
    Takiwaki, Masaki
    Nomura, Fumio
    Satoh, Mamoru
    Tsuchida, Sachio
    Otake, Kazuo
    Takagi, Junko
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1181
  • [40] Development and validation of a liquid chromatography-tandem mass spectrometry method for quantification of Lupeol in plasma and its application to pharmacokinetic study in rats
    Khatal, Laxman
    More, Harinath
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1121 : 58 - 65