Post-cracking behaviour of steel fibre reinforced concrete

被引:209
|
作者
Barros, JAO [1 ]
Cunha, VMCF [1 ]
Ribeiro, AF [1 ]
Antunes, JAB [1 ]
机构
[1] Univ Minho, Sch Eng, Dep Civil Eng, P-4810058 Guimaraes, Portugal
关键词
D O I
10.1007/BF02480574
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recently, RILEM TC 162-TDF has proposed equivalent, f(eq), and residual, f(R), flexural tensile strength parameters to characterize and simulate the post-cracking behaviour of steel fibre reinforced concrete (SFRC) structures. In the current work, more than two hundred flexural tests are carried out according to the RILEM TC 162-TDF recommendations and the corresponding values of f(eq) and f(R) parameters are evaluated. In series of specimens reinforced with fibres of a distinct length/diameter ratio, similar values of f(eq) and f(R) parameters were obtained in these series. Although a strong correlation between f(eq) and f(R) was determined, a larger scatter of f(R) values was observed thereby revealing f(eq) to be more appropriate for design purposes. A numerical strategy involving a cross sectional layered model and an inverse analysis was developed to evaluate the post-cracking stress-strain and the stress-crack opening diagrams for the tested SFRC. This strategy was also used to determine a relation between the post-cracking strain, epsilon(per), and the crack opening displacement, w, (epsilon(per) = w/L-p) which is useful for evaluating the crack opening when numerical strategies based on a stress-strain approach are used. The obtained L-p values range from half the specimen cross section height to half the distance between the tip of the notch and the top of the cross section. (c) 2004 RILEM. All rights reserved.
引用
收藏
页码:47 / 56
页数:10
相关论文
共 50 条
  • [31] Size Effect on Post-cracking Strength of High Performance Fibre-Reinforced Concrete
    Galeote, Eduardo
    Blanco, Ana
    de la Fuente, Albert
    Goodier, Chris
    Austin, Simon
    HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET, 2018, : 182 - 190
  • [32] Post-cracking performance of recycled polypropylene fibre in concrete
    Yin, Shi
    Tuladhar, Rabin
    Collister, Tony
    Combe, Mark
    Sivakugan, Nagaratnam
    Deng, Zongcai
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 101 : 1069 - 1077
  • [33] Evaluation of the influence of post-cracking response of steel fibre reinforced concrete (SFRC) on load carrying capacity of SFRC panels
    Salehian, Hamidreza
    Barros, Joaquim A. O.
    Taheri, Mahsa
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 73 : 289 - 304
  • [34] Post-Cracking Behaviour of Fibre-Reinforced Shotcrete: A Numerical Comparison between Beams and Panels
    Ostlund, Lina
    Sjolander, Andreas
    Brodd, Elin
    FIBERS, 2023, 11 (07)
  • [35] Modelling of the pre and post-cracking response of the PVA fibre reinforced concrete subjected to direct tension
    Khan, Sadaqat Ullah
    Ayub, Tehmina
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 120 : 540 - 557
  • [36] FRACTURE AND POST-CRACKING BEHAVIOR PREDICTION FOR GLASS AND CARBON FIBRE REINFORCED CONCRETE CONSTRUCTION MEMBERS
    Krasnikovs, A.
    Kononova, O.
    Khabbaz, A.
    FIBRE CONCRETE 2009: TECHNOLOGY, DESIGN, APPLICATION, 2009, : 161 - 166
  • [37] Influence of the Chloride Attack on the Post-Cracking Behavior of Recycled Steel Fiber Reinforced Concrete
    Frazao, Cristina
    Barros, Joaquim
    Bogas, Jose Alexandre
    MATERIALS, 2021, 14 (05) : 1 - 26
  • [38] Assessment of the Post-Cracking Fatigue Behavior of Steel and Polyolefin Fiber-Reinforced Concrete
    Enfedaque, Alejandro
    Alberti, Marcos G.
    Galvez, Jaime C.
    Proano, Jhonatan Santiago
    MATERIALS, 2021, 14 (22)
  • [39] Post-cracking shear modulus of reinforced concrete membrane elements
    Rahal, Khaldoun N.
    ENGINEERING STRUCTURES, 2010, 32 (01) : 218 - 225
  • [40] MICROMECHANICAL INVESTIGATION OF STEEL FIBER REINFORCED HIGH-PERFORMANCE CONCRETE POST-CRACKING BEHAVIOR
    Krasnikovs, A.
    Kononova, O.
    Pupurs, A.
    FIBRE CONCRETE 2009: TECHNOLOGY, DESIGN, APPLICATION, 2009, : 155 - 160