Optimal calibration for rotating analyzer ellipsometer

被引:1
|
作者
Park, S
Gweon, D
机构
[1] Optel Precis Co, Iksan, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Mech Engn, Taejon, South Korea
关键词
ellipsometer; optimal calibration;
D O I
10.1007/BF02916514
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
We have modeled most errors, which affect the measurement accuracy, with Jone's matrix. From the simulation, we can characterize the errors and take good aids for selecting components and designing ellipsometer. The traditional residual method has good performance when there are only azimuth angle errors and extinction errors, but it has not good performance when there are other errors. We have proposed the optimal calibration method for overcoming the residual method. The optimal method selects error values to have the least square difference between the measured thickness and the simulated thickness. We can reduce the design variables to three, incident angle error, and azimuth angle errors of polarizer and analyzer. The optimization results are slightly different from the residual method, and have smaller standard deviation of errors than the residual method. The experiment shows good agreement with the simulations.
引用
收藏
页码:2165 / 2171
页数:7
相关论文
共 50 条
  • [1] Optimal calibration for rotating analyzer ellipsometer
    Sunglim Park
    DaeGab Gweon
    Journal of Mechanical Science and Technology, 2005, 19 : 2165 - 2171
  • [2] Rotating analyzer-fixed analyzer ellipsometer based on null type ellipsometer
    Russev, SC
    Arguirov, TV
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (07): : 3077 - 3082
  • [3] Rotating analyzer-fixed analyzer ellipsometer based on null type ellipsometer
    Russev, Stoyan C.
    Arguirov, Tzanimir Vl.
    Review of Scientific Instruments, 70 (07):
  • [4] Calibration method of the specific characteristic of an electronic system of a rotating-analyzer ellipsometer
    Kawabata, S
    Motoki, M
    Yokota, H
    APPLIED OPTICS, 1997, 36 (10): : 2178 - 2182
  • [5] SCANNING ELLIPSOMETER BY ROTATING POLARIZER AND ANALYZER
    CHEN, LY
    LYNCH, DW
    APPLIED OPTICS, 1987, 26 (24) : 5221 - 5228
  • [6] AUTOMATED NULL ELLIPSOMETER WITH ROTATING ANALYZER
    SCHROTTKE, L
    JUNGK, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (12): : 3657 - 3660
  • [7] Analysis of error and development of calibration's method to design precision rotating analyzer ellipsometer
    Gil, H
    Park, S
    Jung, JW
    Gweon, D
    OPTOMECHATRONIC SYSTEMS, 2001, 4190 : 92 - 101
  • [8] Development and construction of rotating polarizer analyzer ellipsometer
    El-Agez, Taher M.
    Taya, Sofyan A.
    OPTICS AND LASERS IN ENGINEERING, 2011, 49 (04) : 507 - 513
  • [9] Rotating polarizer analyzer ellipsometer with a fixed compensator
    Taya, Sofyan A.
    El-Agez, Taher M.
    OPTIK, 2013, 124 (18): : 3379 - 3383
  • [10] Rotating polarizer-analyzer scanning ellipsometer
    El-Agez, Taher M.
    El Tayyan, Ahmed A.
    Taya, Sofyan A.
    THIN SOLID FILMS, 2010, 518 (19) : 5610 - 5614