Optimal Hybrid PV Array Topologies to Maximize the Power Output by Reducing the Effect of Non-Uniform Operating Conditions

被引:8
|
作者
Raju Pendem, Suneel [1 ]
Mikkili, Suresh [2 ]
Rangarajan, Shriram S. [1 ,3 ]
Avv, Sudhakar [1 ]
Collins, Randolph E. [3 ]
Senjyu, Tomonobu [4 ]
机构
[1] SR Univ, Dept Elect & Elect Engn, Warangal 506371, Andhra Pradesh, India
[2] Natl Inst Technol Goa, Dept Elect & Elect Engn, Ponda 403401, India
[3] Clemson Univ, Dept Elect & Comp Engn, Clemson, SC 29634 USA
[4] Univ Ryukyus, Dept Elect & Elect Engn, Okinawa 9030213, Japan
关键词
photovoltaic (PV) system; hybrid array topologies; non-uniform operating conditions (NUOCs); mismatching power loss; conversion efficiency; PARTIAL SHADING CONDITIONS; PHOTOVOLTAIC SYSTEMS; POINT TRACKING; RECONFIGURATION SCHEME; INVERTER TOPOLOGIES; EXTRACTION; CONVERTER; MODEL; CONFIGURATION; ENHANCEMENT;
D O I
10.3390/electronics10233014
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The photovoltaic (PV) system center inverter architecture comprises various conventional array topologies such as simple-series (S-S), parallel (P), series-parallel (S-P), total-cross-tied (T-C-T), bridge-linked (B-L), and honey-comb (H-C). The conventional PV array topologies under non-uniform operating conditions (NUOCs) produce a higher amount of mismatching power loss and represent multiple maximum-power-points (M-P-Ps) in the output characteristics. The performance of T-C-T topology is found superior among the conventional topologies under NUOCs. However, T-C-T topology's main limitations are higher redundancy, more number of electrical connections, higher cabling loss, poor performance during row-wise shading patterns, and more number of switches and sensors for the re-configuration of PV modules. This paper proposes the various optimal hybrid PV array topologies to overcome the limitations of conventional T-C-T array topology. The proposed hybrid topologies are such as series-parallel-cross-tied (S-P-C-T), bridge-link-cross-tied (B-L-C-T), honey-comb-cross-tied (H-C-C-T), series-parallel-total-cross-tied (S-P-T-C-T), bridge-link-total-cross-tied (B-L-T-C-T), honey-comb-total-cross-tied (H-C-T-C-T), and bridge-link-honey-comb (B-L-H-C). The proposed hybrid topologies performance is evaluated and compared with the conventional topologies under various NUOCs. The parameters used for the comparative study are open-circuit voltage, short-circuit current, global-maximum-power-point (GMPP), local-maximum-power-point (LMPP), number of LMPPs, and fill factor (FF). Furthermore, the mismatched power loss and the conversion efficiency of conventional and hybrid array topologies are also determined. Based on the results, it is found that the hybrid array topologies maximize the power output by mitigating the effect of NUOCs and reducing the number of LMPPs.
引用
收藏
页数:25
相关论文
共 32 条
  • [21] Maximum Power Point Tracking of PV Array under Non-Uniform Irradiance Using Artificial Neural Network
    Ramana, Vanjari Venkata
    Jena, Debashisha
    2015 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, INFORMATICS, COMMUNICATION AND ENERGY SYSTEMS (SPICES), 2015,
  • [22] Reactive power management stretegy for photovoltaic based distributed generators operating under non-uniform conditions
    Patel, Urvi
    Shah, Neha
    Patel, Hiren
    2018 INTERNATIONAL CONFERENCE ON POWER ENERGY, ENVIRONMENT AND INTELLIGENT CONTROL (PEEIC), 2018, : 722 - 729
  • [23] An Experimental Investigation on Output Power Enhancement With Offline Reconfiguration for Non-Uniform Aging Photovoltaic Array to Maximise Economic Benefit
    Alkahtani, Mohammed
    Zhou, Jiafeng
    Hu, Yihua
    Alkasmoul, Fahad
    Kiani, Zeryab Hassan
    Kuka, Colin Sokol
    IEEE ACCESS, 2021, 9 : 87510 - 87519
  • [24] Effect of Pulse-Shifting on Calculating Sideband Power Losses in Non-uniform Time-Modulated Array
    Mandal, Sujoy
    Mandal, Sujit Kumar
    ELECTROMAGNETICS, 2023, 43 (06) : 375 - 387
  • [25] Selectorless resistive switching memory: Non-uniform dielectric architecture and seasoning effect for low power array applications
    Chen, Ying-Chen
    Huang, Hui-Chun
    Lin, Chih-Yang
    Hu, Szu-Tung
    Lin, Chao-Cheng
    Lee, Jack C.
    AIP ADVANCES, 2019, 9 (07):
  • [26] Transient performance assessment of a hybrid PV-TEG system integrated with PCM under non-uniform radiation conditions: A numerical investigation
    Gao, Yuanzhi
    Dai, Zhaofeng
    Wu, Dongxu
    Wang, Changling
    Chen, Bo
    Zhang, Xiaosong
    RENEWABLE ENERGY, 2022, 198 : 352 - 366
  • [27] Development of Photovoltaic (PV) Cell/Module/Array and Non-uniform Irradiance Effect Based on Two-diode Model by Using PSPICE Simulator
    Dash, Soubhagya Kumar
    Raj, R. Akhil
    Nema, Savita
    Nema, R. K.
    2015 INTERNATIONAL CONFERENCE ON NASCENT TECHNOLOGIES IN THE ENGINEERING FIELD (ICNTE), 2015,
  • [28] Optimal Su-Do-Ku based interconnection scheme for increased power output from PV array under partial shading conditions
    Rao, P. Srinivasa
    Dinesh, P.
    Ilango, G. Saravana
    Nagamani, C.
    FRONTIERS IN ENERGY, 2015, 9 (02) : 199 - 210
  • [29] Optimal Su-Do-Ku based interconnection scheme for increased power output from PV array under partial shading conditions
    P. Srinivasa Rao
    P. Dinesh
    G. Saravana Ilango
    C. Nagamani
    Frontiers in Energy, 2015, 9 : 199 - 210
  • [30] Novel Hybrid PV Array Configurations for extracting maximum Power by reducing number of peaks and mitigating mismatching power loss under partial shading conditions.
    Desai, Aditi Atul
    Mikkili, Suresh
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 1872 - 1877