A gas microstrip X-ray detector for soft energy fluorescence EXAFS

被引:12
|
作者
Smith, AD
Bateman, JE
Derbyshire, GE
Duxbury, DM
Lipp, J
Spill, EJ
Stephenson, R
机构
[1] CLRC, Daresbury Lab, Synchrotron Radiat Lab, Warrington WA4 4AD, Cheshire, England
[2] Rutherford Appleton Lab, Didcot OX11 0QX, Oxon, England
关键词
gas microstrip; X-ray detectors; soft X-ray spectroscopy;
D O I
10.1016/S0168-9002(01)00563-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Gas microstrip detectors have been previously developed by the particle physics community, where their robustness, compactness and high counting speed have been recognised. These features are particularly attractive to synchrotron radiation use. In this paper, we describe a gas microstrip detector employing multi-element readout and specifically developed for high count rate fluorescence EXAFS at soft X-ray energies below 4 keV. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1136 / 1139
页数:4
相关论文
共 50 条
  • [21] Image x-ray emission converters and microstrip porous dielectric x-ray detector
    Lorikyan, M. P.
    JOURNAL OF APPLIED PHYSICS, 2008, 104 (09)
  • [22] A gas microstrip wide angle X-ray detector for application in synchrotron radiation experiments
    Bateman, JE
    Connolly, JF
    Derbyshire, GE
    Duxbury, DM
    Lipp, J
    Mir, JA
    Simmons, JE
    Spill, EJ
    Stephenson, R
    Dobson, BR
    Farrow, RC
    Helsby, WI
    Mutikainen, R
    Suni, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 340 - 346
  • [23] The capabilities of an electrically cooled energy-dispersive x-ray detector for quantitative x-ray fluorescence analysis
    Kump, P
    Necemer, M
    Drinovec, J
    X-RAY SPECTROMETRY, 2004, 33 (02) : 107 - 111
  • [24] X-ray polarimetry with the microstrip gas chamber
    Nishi, Y
    Aoki, S
    Ochi, A
    Tanimori, T
    Takahashi, T
    Ueda, Y
    Okada, K
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 857 - 859
  • [25] X-ray polarimetry with the microstrip gas chamber
    J. Synchrotron Radiat., 3 (857-859):
  • [26] EXAFS and X-ray fluorescence of zeolite photocatalysts with ZnO nanoparticles
    Khouchaf, L
    Tullier, MH
    Durr, J
    Wark, M
    Kessler, H
    JOURNAL DE PHYSIQUE IV, 1996, 6 (C4): : 939 - 945
  • [27] Design of X-ray energy detector
    Zeng F.
    Zhu Z.
    Energy Reports, 2022, 8 : 456 - 460
  • [28] Design of X-ray energy detector
    Zeng, Fan
    Zhu, Zhiyuan
    ENERGY REPORTS, 2022, 8 : 456 - 460
  • [29] Accurate reconstruction of soft X-ray energy spectrum in detector response matrix
    Gao, RunLong
    Liu, Yang
    Ouyang, XiaoPing
    Chen, Jing
    Ouyang, Xiao
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2019, 62 (12)
  • [30] Accurate reconstruction of soft X-ray energy spectrum in detector response matrix
    RunLong Gao
    Yang Liu
    XiaoPing Ouyang
    Jing Chen
    Xiao Ouyang
    Science China Physics, Mechanics & Astronomy, 2019, 62