Detection of Concrete Cover of Reinforcements in Reinforced Concrete Wall by Microwave Thermography with Transmission Approach

被引:7
|
作者
Keo, Sam Ang [1 ]
Brachelet, Franck [2 ]
Defer, Didier [2 ]
Breaban, Florin [2 ]
机构
[1] Cerema, Res Team ENDSUM, 23 Amiral Chauvin Ave, F-49130 Les Ponts De Ce, France
[2] Univ Artois, IMT Nord Europe, Junia, Univ Lille,ULR 4515,Lab Genie Civil & GeoEnvironm, F-62400 Bethune, France
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 19期
关键词
structural health monitoring (SHM); electromagnetic nondestructive evaluation (NDE); microwave thermography; concrete cover thickness; steel reinforcements; reinforced concrete (RC) wall; NONDESTRUCTIVE EVALUATION; INFRARED THERMOGRAPHY; DEFECT RECOGNITION; RADAR;
D O I
10.3390/app12199865
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Concrete cover has an important role in reinforced concrete (RC) structures because it protects reinforcement bars from the bad effects of weather, fire, and bad environmental conditions that cause the corrosion of the reinforcements. Although it is an essential parameter to be considered for structural health monitoring (SHM), its detection by infrared thermography, especially in the heating phase, has not been accessed yet. The detailed analysis and discussions of physical phenomena, known as diffraction and interference, affecting the thermograms during the detection of the steel bars by microwave thermography have given an essential key for resolving this issue. The present paper proposes an innovative methodology with microwave thermography for determining the concrete cover thickness of one-layer reinforcements (12 mm in diameter and regularly placed at 10 cm) in an RC wall (1 m x 1 m x 6.5 cm). By using the transmission approach with five angles of microwave antenna direction (0 degrees, 15 degrees, 30 degrees, 45 degrees, and 60 degrees) and the Snell-Descartes law and linear law, the proposed methodology leads us to deduce the approximate value of the concrete cover thickness (37.74 mm), which is close to the real value (38 mm), as well as the spacing of the steel bars and dielectric constant of the concrete. The detection of the concrete cover thickness is another new remarkable achievement of infrared thermography methods.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Seismic Performance of Prestressed Reinforced Concrete Piles Reinforced with Nonprestressed Reinforcements
    Wang, Tiecheng
    Wang, Wenjin
    Zhao, Hailong
    Yang, Zhijian
    CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE II, PTS 1 AND 2, 2013, 438-439 : 1466 - 1470
  • [22] A new approach for nonlinear finite element analysis of reinforced concrete structures with corroded reinforcements
    Shayanfar, Mohsen A.
    Safiey, Amir
    COMPUTERS AND CONCRETE, 2008, 5 (02): : 155 - 174
  • [23] Flexural behavior of concrete beam reinforced with GFRP bars compared to concrete beam reinforced with conventional steel reinforcements
    Sirimontree S.
    Keawsawasvong S.
    Thongchom C.
    Journal of Applied Science and Engineering, 2021, 24 (06): : 883 - 890
  • [24] Quantitative approach for damage detection of reinforced concrete frames
    Yoshio Kaneko
    Akira Mita
    Hirozo Mihashi
    Earthquake Engineering and Engineering Vibration, 2003, 2 (1) : 147 - 158
  • [25] Quantitative approach for damage detection of reinforced concrete frames
    Yoshio Kaneko
    Akira Mita
    Hirozo Mihashi
    Earthquake Engineering and Engineering Vibration, 2003, 2 (01) : 147 - 158
  • [26] Research on the reinforcement ratio and the thickness of concrete cover of reinforced concrete model
    Huang, Liang
    Huang, Mei-Mei
    Cao, Hai-Xin
    Wu, Zhi-Wei
    Yan, You-Qing
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2013, 40 (02): : 26 - 30
  • [27] Prediction of Concrete Cover Separation in Reinforced Concrete Beams Strengthened with FRP
    Al-Ghrery, Khattab
    Kalfat, Robin
    Al-Mahaidi, Riadh
    Oukaili, Nazar
    Al-Mosawe, Alaa
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2021, 25 (04)
  • [28] Influence of concrete cover on fire resistance of reinforced concrete flexural members
    Shi, XD
    Tan, TH
    Tan, KH
    Guo, ZH
    JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (08) : 1225 - 1232
  • [29] Effect of concrete cover on the pure torsional behavior of reinforced concrete beams
    Ibrahim, Mohammed Sirage
    Gebreyouhannes, Esayas
    Muhdin, Abdulkerim
    Gebre, Abrham
    ENGINEERING STRUCTURES, 2020, 216
  • [30] Investigate the performance of the removal of a cover concrete over a reinforced concrete column
    Ramasubramani, R.
    Harikrishnan
    MATERIALS TODAY-PROCEEDINGS, 2022, 65 : 12 - 19