Subscapularis structural integrity and function after arthroscopic Latarjet procedure at a minimum 2-year follow-up

被引:20
|
作者
Valencia, Maria [1 ]
Fernandez-Bermejo, Gloria [2 ]
Martin-Rios, Maria D. [3 ]
Fernandez-Jara, Javier [4 ]
Morcillo-Barrenechea, Diana [1 ]
Coifman-Lucena, Ismael [1 ]
Foruria, Antonio M. [1 ]
Calvo, Emilio [1 ]
机构
[1] Hosp Univ Fdn Jimenez Diaz, Dept Orthoped Surg & Traumatol, Reconstruct Surg Unit, Madrid, Spain
[2] Hosp Univ Fdn Jimenez Diaz, Phys Med & Rehabil Dept, Madrid, Spain
[3] Hosp Univ Fdn Jimenez Diaz, Dept Epidemiol, Madrid, Spain
[4] Hosp Univ Fdn Jimenez Diaz, Musculoskeletal Radiol Dept, Madrid, Spain
关键词
Shoulder instability; arthroscopic; Latarjet; subscapularis; splitting; fatty atrophy; isokinetic; CT scan; RECURRENT ANTERIOR DISLOCATION; ROTATOR CUFF MUSCLES; QUANTITATIVE ASSESSMENT; FATTY DEGENERATION; SHOULDER INSTABILITY; COMPUTED-TOMOGRAPHY; BONE-BLOCK; STRENGTH; TENOTOMY; REPAIR;
D O I
10.1016/j.jse.2019.05.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Subscapularis function after arthroscopic Bankart repair has been widely studied. However, data regarding subscapularis performance after arthroscopic Latarjet procedures are lacking. This study aimed to evaluate subscapularis clinical and radiologic performance after arthroscopic Latarjet procedures. Methods: We included 40 patients who underwent arthroscopic Latarjet procedure with a minimum 2-year follow-up. Clinical evaluation included Western Ontario Shoulder Instability Index and Rowe scores, specific subscapularis isokinetic study, and lift-off tests. Contralateral measurements were used for comparison. Computed tomographic evaluation included graft consolidation, muscle dimensions, and degree of fatty atrophy, calculated as the mean muscle attenuation (MMA). Results: There was a decrease of 8.3% of maximum internal rotation peak torque in the operated arm (P = .02). However, there was no significant difference in the agonist-antagonist ratio: 76.9% in the operated arm and 76% in the contralateral (P = .82). Lift-off strength test demonstrated a decrease in the first year but not at final follow-up (P = .38). There was a significant decrease in lift-off distance of 23% compared to the contralateral side (P <.001). Subscapularis MMA was diminished when compared to the infraspinatus/teres minor (P <.001) at the expense of its upper part (P = .03). Hyperlaxity and number of dislocation episodes were correlated to a lower MMA (P = .046 and P = .005). Conclusion: Arthroscopic Latarjet procedures provide satisfactory clinical results. There seems to be a diminished subscapularis MMA depending on its superior half. Hyperlaxity and number of previous dislocations were correlated to a lower MMA. Although there was a decrease in the maximum internal rotation peak torque, we did not find any difference in the agonist-antagonist ratio or in the final lift-off strength between sides. (C) 2019 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:104 / 112
页数:9
相关论文
共 50 条
  • [41] Risk factors for septic arthritis and multiple arthroscopic washouts: minimum 2-year follow-up at a major trauma centre
    Victor Lu
    Andrew Zhou
    Hassan Abbas Hussain
    Azeem Thahir
    Matija Krkovic
    Clinical Rheumatology, 2022, 41 : 2513 - 2523
  • [42] Arthroscopic acetabuloplasty without labral detachment for focal pincer-type impingement: a minimum 2-year follow-up
    Comba, Fernando M.
    Slullitel, Pablo A.
    Bronenberg, Pedro
    Zanotti, Gerardo
    Buttaro, Martin A.
    Piccaluga, Francisco
    JOURNAL OF HIP PRESERVATION SURGERY, 2017, 4 (02): : 145 - 152
  • [43] Risk factors for septic arthritis and multiple arthroscopic washouts: minimum 2-year follow-up at a major trauma centre
    Lu, Victor
    Zhou, Andrew
    Hussain, Hassan Abbas
    Thahir, Azeem
    Krkovic, Matija
    CLINICAL RHEUMATOLOGY, 2022, 41 (08) : 2513 - 2523
  • [44] Effect of Modified Arthroscopic Latarjet on Acromiohumeral Distance at 5-Year Follow-up
    Liang, Daqiang
    Liu, Haifeng
    Liang, Xinzhi
    Qin, Qihuang
    Long, Lujue
    Huang, Yong
    Lu, Wei
    Deng, Zhenhan
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (12)
  • [45] 2-YEAR FOLLOW-UP OF AGORAPHOBICS AFTER EXPOSURE AND IMIPRAMINE
    COHEN, SD
    MONTEIRO, W
    MARKS, IM
    BRITISH JOURNAL OF PSYCHIATRY, 1984, 144 (MAR) : 276 - 281
  • [46] Cognitive recovery after stroke: A 2-year follow-up
    Hochstenbach, JB
    Mulder, TW
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2003, 84 (10): : 1499 - 1504
  • [47] 2-YEAR FOLLOW-UP ON PATIENTS AFTER TRABECULECTOMY WITH MITOMYCIN
    KALINA, PH
    JOHNSON, SM
    SHIELDS, SR
    HUTCHINSON, BT
    BELLOWS, AR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S87 - S87
  • [48] The effect of subscapularis repair in reverse total shoulder arthroplasty depends on the design of the implant: a comparative study with a minimum 2-year follow-up
    Fabrizio Mocini
    Simone Cerciello
    Katia Corona
    Brent J. Morris
    Luca Saturnino
    Matthew C. Giordano
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 41 - 49
  • [49] The effect of subscapularis repair in reverse total shoulder arthroplasty depends on the design of the implant: a comparative study with a minimum 2-year follow-up
    Mocini, Fabrizio
    Cerciello, Simone
    Corona, Katia
    Morris, Brent J.
    Saturnino, Luca
    Giordano, Matthew C.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (01) : 41 - 49
  • [50] Outcomes of Endoscopic Gluteus Medius Repair With Minimum 2-Year Follow-up
    Domb, Benjamin G.
    Botser, Itamar
    Giordano, Brian D.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (05): : 988 - 997