Tests of a precision tiltmeter system for measuring telescope position

被引:2
|
作者
Kibrick, R [1 ]
Robinson, L [1 ]
Wallace, V [1 ]
Cowley, D [1 ]
机构
[1] Univ Calif Santa Cruz, Lick Observ, Santa Cruz, CA 95064 USA
来源
关键词
telescope pointing; gravity-referenced telescope position measurement; tilt sensors; tilt-stabilization;
D O I
10.1117/12.308805
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We have previously described a system that derives the pointing coordinates of an equatorial telescope by measuring the angular position of a dual-axis tilt-table whose frame is rigidly attached to the telescope's primary mirror cell.(1) In that system, two precision tilt-sensors aligned orthogonally and mounted in the plane of the table are used as nulling devices to close an active servo loop which holds the table level as the telescope moves. Rotary encoders measure the angle by which each tilt-table axis rotates, and a mathematical transform converts those encoder readings into telescope hour angle and declination. Recent work has indicated the feasibility of several simplifications to that system. First, by use of suitable low friction bearings on the tilt-table axes, along with non-contacting encoders, the active servo loop is no longer needed to level the tilt-table. Rather, a simple suspended weight keeps the platform almost level, with the residual small tilt error measured by the precision tilt sensors. Second, by suitable orientation of the weight and the tilt sensors relative to the telescope polar axis, the system can measure telescope hour angle and declination directly, eliminating the need for the complex mathematical transform. Experimental results using these ideas are presented.
引用
收藏
页码:342 / 353
页数:12
相关论文
共 50 条
  • [31] HUBBLE SPACE TELESCOPE PRECISION POINTING CONTROL-SYSTEM
    BEALS, GA
    CRUM, RC
    DOUGHERTY, HJ
    HEGEL, DK
    KELLEY, JL
    RODDEN, JJ
    JOURNAL OF GUIDANCE CONTROL AND DYNAMICS, 1988, 11 (02) : 119 - 123
  • [32] Friction modeling and compensation of precision position system
    Ma L.
    Wang J.-P.
    Li F.-T.
    Zeng Y.-X.
    Liu Z.-L.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (01): : 121 - 128
  • [33] Study of a high-precision pulsar angular position measuring method
    Li, Yao
    Su, Tong
    Sheng, Lizhi
    Qiang, Pengfei
    Zhao, Baosheng
    MODERN PHYSICS LETTERS B, 2018, 32 (29):
  • [34] MEASURING THE POSITION OF MOVING ATOMS WITH UNCERTAINTY-PRINCIPLE-LIMITED PRECISION
    THOMAS, JE
    CONTEMPORARY PHYSICS, 1994, 35 (04) : 257 - 267
  • [35] MEASURING HIGH-PRECISION ASTROMETRY WITH THE INFRARED ARRAY CAMERA ON THE SPITZER SPACE TELESCOPE
    Esplin, T. L.
    Luhman, K. L.
    ASTRONOMICAL JOURNAL, 2016, 151 (01):
  • [36] CCD precision angle-measuring system
    Wang, Fu
    Cheng, Shoucheng
    Liu, Bingqi
    Shen, Xueju
    Chinese Acad Sci, Sichuan, China (24):
  • [37] Design Method of Measuring Rheogeniometer System Precision
    Liu, Chunli
    Yan, Feng
    EQUIPMENT MANUFACTURING TECHNOLOGY, 2012, 422 : 300 - 303
  • [38] A method to improve the precision of measuring focusing system
    Xu, Xiaoliang
    An, Tao
    Chen, Ke
    AOPC 2015: TELESCOPE AND SPACE OPTICAL INSTRUMENTATION, 2015, 9678
  • [39] RESEARCH ENGINEERS PRECISION COORDINATE MEASURING SYSTEM
    不详
    MACHINERY AND PRODUCTION ENGINEERING, 1972, 121 (3118): : 248 - &
  • [40] A PRECISION LANGMUIR FILM BALANCE MEASURING SYSTEM
    ALBRECHT, O
    SACKMANN, E
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1980, 13 (05): : 512 - 515