In this paper the full house hygrothermal performance of an aerated concrete wall system is examined for the hot and humid climate of Miami. The results clearly demonstrated the limited drying potential for the wall system in that climate. The selected exterior thermal insulation strategies and interior vapor control strategies in this study show the critical behavior of the full house with respect to drying initial construction moisture. Moisture related problems such as mold growth are simulated and discussed. From these results moisture control strategies are identified for the whole house hygrothermal performance. (C) 2001 Published by Elsevier Science Ltd.
引用
收藏
页码:779 / 787
页数:9
相关论文
共 50 条
  • [21] Determination of hygrothermal performance of building envelope by computer simulation
    Bina kabuǧunun nemsel-isil performansinin bilgisayar benzetimi ile belirlenmesi
    1600, Gazi Universitesi (29):
  • [22] Determination of hygrothermal performance of building envelope by computer simulation
    Bina kabugunun nemsel-isil performansinin bilgisayar benzetimi ile belirlenmesi
    1600, Gazi Universitesi (29):
  • [23] TURBOEXPANDER EFFICIENCY .2. EXAMPLES SHOW SYSTEM-PERFORMANCE UPGRADE
    MCINTIRE, R
    OIL & GAS JOURNAL, 1982, 80 (28) : 125 - &
  • [24] Faster maximum and minimum mean cycle algorithms for system-performance analysis
    Dasdan, A
    Gupta, RK
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 1998, 17 (10) : 889 - 899
  • [25] Gray internal forecasting of loads of building hygrothermal system
    Wang, XM
    Yang, CZ
    Chen, ZK
    Chen, YM
    ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 294 - 301
  • [26] Study for hygrothermal performance of attic in consideration of airtightness of wood-frame house based on whole building ham analyses
    Saito, Hiroaki
    Honma, Yoshinori
    Miura, Hisashi
    Suzuki, Hirotaka
    AIJ Journal of Technology and Design, 2011, 17 (35) : 221 - 226
  • [27] Determination of indoor humidity profile using a whole-building hygrothermal model
    Tariku, Fitsum
    Kumaran, Kumar
    Fazio, Paul
    BUILDING SIMULATION, 2011, 4 (01) : 61 - 78
  • [28] Simulation of whole building coupled hygrothermal-airflow transfer in different climates
    Qin, Menghao
    Walton, George
    Belarbi, Rafik
    Allard, Francis
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (02) : 1470 - 1478
  • [29] Combined simulation of central HVAC systems with a whole-building hygrothermal model
    Barbosa, Rogerio Marcos
    Mendes, Nathan
    ENERGY AND BUILDINGS, 2008, 40 (03) : 276 - 288
  • [30] Determination of indoor humidity profile using a whole-building hygrothermal model
    Fitsum Tariku
    Kumar Kumaran
    Paul Fazio
    Building Simulation, 2011, 4 : 61 - 78