Hygrothermal system-performance of a whole building

被引:31
|
作者
Karagiozis, A [1 ]
Salonvaara, M [1 ]
机构
[1] Oak Ridge Natl Lab, Div Energy, Bldg Technol Ctr, Oak Ridge, TN USA
关键词
moisture control; moisture engineering; building envelope modeling; whole building performance; aerated concrete;
D O I
10.1016/S0360-1323(00)00063-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper the full house hygrothermal performance of an aerated concrete wall system is examined for the hot and humid climate of Miami. The results clearly demonstrated the limited drying potential for the wall system in that climate. The selected exterior thermal insulation strategies and interior vapor control strategies in this study show the critical behavior of the full house with respect to drying initial construction moisture. Moisture related problems such as mold growth are simulated and discussed. From these results moisture control strategies are identified for the whole house hygrothermal performance. (C) 2001 Published by Elsevier Science Ltd.
引用
收藏
页码:779 / 787
页数:9
相关论文
共 50 条
  • [1] Methods to determine whole building hygrothermal performance of hemp-lime buildings
    Barclay, M.
    Holcroft, N.
    Shea, A. D.
    BUILDING AND ENVIRONMENT, 2014, 80 : 204 - 212
  • [2] Whole building approach and hygrothermal risk analysis
    Hens, H.
    Carmeliet, J.
    Roels, S.
    Janssen, H.
    RESEARCH IN BUILDING PHYSICS AND BUILDING ENGINEERING, 2006, : 519 - +
  • [3] Performance evaluation of indirect evaporative cooling using whole-building hygrothermal simulations
    Steeman, Marijke
    Janssens, Arnold
    De Paepe, Michel
    APPLIED THERMAL ENGINEERING, 2009, 29 (14-15) : 2870 - 2875
  • [4] ON THE INTEGRATION OF HYGROTHERMAL BRIDGES INTO WHOLE BUILDING HAM MODELING
    Berger, Julien
    Rouchier, Simon
    Tasca-Guernouti, Sihem
    Woloszyn, Monika
    Buhe, Catherine
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 3578 - 3585
  • [5] Hygrothermal performance of building papers and housewraps
    Lstribure, JW
    THERMAL PERFORMANCE OF THE EXTERIOR ENVELOPES OF BUILDINGS VII, CONFERENCE PROCEEDINGS, 1998, : 855 - 855
  • [6] TOPEX/Poseidon electrical power system-performance
    Sherwood, R
    Deligiannis, F
    IECEC 96 - PROCEEDINGS OF THE 31ST INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4, 1996, : 399 - 404
  • [7] CONSTRUCTION FACILITIES AUDIT - QUALITY SYSTEM-PERFORMANCE CONTROL
    SAMUELS, AF
    JOURNAL OF MANAGEMENT IN ENGINEERING, 1994, 10 (04) : 60 - 65
  • [8] An improved explicit scheme for whole-building hygrothermal simulation
    Gasparin, Suelen
    Berger, Julien
    Dutykh, Denys
    Mendes, Nathan
    BUILDING SIMULATION, 2018, 11 (03) : 465 - 481
  • [9] Moisture buffering and its consequence in whole building hygrothermal modeling
    Rode, Carsten
    Grau, Karl
    JOURNAL OF BUILDING PHYSICS, 2008, 31 (04) : 333 - 360
  • [10] An improved explicit scheme for whole-building hygrothermal simulation
    Suelen Gasparin
    Julien Berger
    Denys Dutykh
    Nathan Mendes
    Building Simulation, 2018, 11 : 465 - 481