Comparison of invasive and non-invasive cylindrical capacitive sensors for electrical measurements of different water solutions and mixtures

被引:22
|
作者
Behzadi, G. [1 ]
Golnabi, H. [2 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Plasma Phys Res Ctr, Tehran, Iran
[2] Sharif Univ Technol, Inst Water & Energy, Tehran, Iran
关键词
Invasive; Non-invasive; Capacitive sensor; Conductivity;
D O I
10.1016/j.sna.2011.03.031
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study design and operation of invasive and non-invasive cylindrical capacitive sensor (CCS) designs for the electrical measurements of water, water solutions, and water mixtures are reported. Operation of the capacitance measurement module for such probes is based on the charge/discharge method. The measured capacitances and resistances for distilled water, mineral water, tap water and salt water samples are reported by using two sensor types and results are compared. The measured capacitance by invasive CCS for distilled water is about 2.28 mu F and by non-invasive CCS is 31.40 pf, which shows a big difference for different probes. Such a difference is due to the electrical conductivity effects on the invasive CCS, which can be used for the conduction study of different liquids. In another study the capacitance values of a binary solution of water plus additive liquids such as antifreeze, petroleum, ethanol, methanol and mixtures of water with fresh and used motor oils are measured. The effects of the guard ring electrodes, and electrode-liquid interactions on the capacitance/resistance measurements for the invasive CCS filled with different water liquids are also investigated. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:359 / 366
页数:8
相关论文
共 50 条
  • [21] Non-invasive nanozyme sensors for urinalysis
    Prasad, Sanjana Naveen
    Bansal, Vipul
    Ramanathan, Rajesh
    Potter, Sir Ian
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2025, 183
  • [22] Comparison of invasive and non-invasive intracranial pressure monitoring
    Hamarat, Y.
    Deimantavicius, M.
    Zakelis, R.
    Bartusis, L.
    Preiksaitis, A.
    Ragauska, A.
    EUROPEAN JOURNAL OF NEUROLOGY, 2018, 25 : 60 - 60
  • [23] Hypoxic imaging: comparison of invasive and non-invasive methods
    Ling, C
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S188 - S188
  • [24] A comparison of invasive and non-invasive dayflowers (Commelinaceae) across experimental nutrient and water gradients
    Burns, JH
    DIVERSITY AND DISTRIBUTIONS, 2004, 10 (5-6) : 387 - 397
  • [25] Trends from Minimally Invasive to Non-invasive Glucose Measurements
    Gusev, M.
    Poposka, L.
    Guseva, E.
    Kostoska, M.
    Koteska, B.
    Simjanoska, M.
    Ackovska, N.
    Stojmenski, A.
    2020 43RD INTERNATIONAL CONVENTION ON INFORMATION, COMMUNICATION AND ELECTRONIC TECHNOLOGY (MIPRO 2020), 2020, : 315 - 320
  • [26] NON-INVASIVE VS INVASIVE BLOOD-PRESSURE MEASUREMENTS
    GRUNDY, BL
    PROCOPIO, P
    SIEBER, FE
    CRITICAL CARE MEDICINE, 1981, 9 (03) : 267 - 267
  • [27] Comparison of non-invasive blood pressure measurement to invasive measurements in the pediatric intensive care unit
    Sankaran, K.
    Givelichian, L.
    Holt, T.
    ACTA PAEDIATRICA, 2007, 96 : 39 - 39
  • [28] SPECTROSCOPIC SYSTEMS FOR NON-INVASIVE MEASUREMENTS
    CALLIS, JB
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1059 - 1060
  • [29] ELECTROCHEMICAL SENSORS FOR INVASIVE AND NON-INVASIVE MONITORING OF BLOOD-GASES
    MINDT, W
    EBERHARD, P
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1982, 9 (2-3) : 105 - 111
  • [30] Non-invasive estimation of shunt: comparison of different hypoxaemia indices
    Kwok, HF
    Mills, GH
    Mahfouf, M
    Linkens, DA
    BRITISH JOURNAL OF ANAESTHESIA, 2002, 89 (01) : 206P - 207P