Comparison of invasive and non-invasive cylindrical capacitive sensors for electrical measurements of different water solutions and mixtures

被引:21
|
作者
Behzadi, G. [1 ]
Golnabi, H. [2 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Plasma Phys Res Ctr, Tehran, Iran
[2] Sharif Univ Technol, Inst Water & Energy, Tehran, Iran
关键词
Invasive; Non-invasive; Capacitive sensor; Conductivity;
D O I
10.1016/j.sna.2011.03.031
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study design and operation of invasive and non-invasive cylindrical capacitive sensor (CCS) designs for the electrical measurements of water, water solutions, and water mixtures are reported. Operation of the capacitance measurement module for such probes is based on the charge/discharge method. The measured capacitances and resistances for distilled water, mineral water, tap water and salt water samples are reported by using two sensor types and results are compared. The measured capacitance by invasive CCS for distilled water is about 2.28 mu F and by non-invasive CCS is 31.40 pf, which shows a big difference for different probes. Such a difference is due to the electrical conductivity effects on the invasive CCS, which can be used for the conduction study of different liquids. In another study the capacitance values of a binary solution of water plus additive liquids such as antifreeze, petroleum, ethanol, methanol and mixtures of water with fresh and used motor oils are measured. The effects of the guard ring electrodes, and electrode-liquid interactions on the capacitance/resistance measurements for the invasive CCS filled with different water liquids are also investigated. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:359 / 366
页数:8
相关论文
共 50 条
  • [1] Non-invasive measurements of fluids by means of capacitive sensors
    Zangl, H.
    Fuchs, A.
    Bretterklieber, Th.
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2009, 126 (1-2): : 8 - 12
  • [2] Comparison of Measurement Possibilities by Non-Invasive Reflectometric Sensors and Invasive Probes
    Pasnikowska-Lukaszuk, Magdalena
    Wlazlo-Cwiklinska, Magda
    Zubrzycki, Jaroslaw
    Suchorab, Zbigniew
    APPLIED SCIENCES-BASEL, 2023, 13 (01):
  • [3] A comparison of invasive and non-invasive arterial blood pressure measurements in the neonate
    Shea, J. E. O'
    Dempsey, E. M.
    ACTA PAEDIATRICA, 2007, 96 : 190 - 191
  • [4] A Laboratory Study on Non-Invasive Soil Water Content Estimation Using Capacitive Based Sensors
    Orangi, Amir
    Narsilio, Guillermo A.
    Ryu, Dongryeol
    SENSORS, 2019, 19 (03)
  • [5] A COMPARISON OF INVASIVE AND NON-INVASIVE ARTERIAL BLOOD PRESSURE MEASUREMENTS IN THE NEONATE
    O'Shea, J.
    Dempsey, E.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 : S174 - S174
  • [6] EPISCLERAL VENOUS-PRESSURE - A COMPARISON OF INVASIVE AND NON-INVASIVE MEASUREMENTS
    GAASTERLAND, DE
    PEDERSON, JE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1983, 24 (10) : 1417 - 1422
  • [7] NON-INVASIVE MEASUREMENTS
    ROUGHTON, JE
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (12): : 1257 - 1270
  • [8] Comparison of optical sensors for non-invasive hemoglobin measurement
    Desai, Brinda
    Chaskar, Uttam
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 2211 - 2214
  • [9] A COMPARISON OF INVASIVE AND NON-INVASIVE ELECTROCOCHLEOGRAPHY
    STEVENS, JC
    JEFFRIES, DD
    BUFFIN, JT
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1983, 4 (01): : 100 - 100
  • [10] A comparison of invasive and non-invasive measurements of the dynamic surface tension in an overflowing cylinder
    ManningBenson, S
    Darton, RC
    Sharpe, D
    Eastoe, J
    Bain, CD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 214 : 271 - PHYS