Correspondence model-based 4D VMAT dose simulation for analysis of local metastasis recurrence after extracranial SBRT

被引:9
|
作者
Sothmann, T. [1 ,2 ]
Gauer, T. [2 ]
Wilms, M. [3 ]
Werner, R. [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Computat Neurosci, Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Radiotherapy & Radiooncol, Hamburg, Germany
[3] Univ Lbeck, Inst Med Informat, Lubeck, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 23期
关键词
respiratory motion; 4D dose simulation; dose accumulation; correspondence model;
D O I
10.1088/1361-6560/aa955b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to introduce a novel approach to incorporate patient-specific breathing variability information into 4D dose simulation of volumetric arc therapy (VMAT)-based stereotactic body radiotherapy (SBRT) of extracranial metastases. Feasibility of the approach is illustrated by application to treatment planning and motion data of lung and liver metastasis patients. The novel 4D dose simulation approach makes use of a regression-based correspondence model that allows representing patient motion variability by breathing signal-steered interpolation and extrapolation of deformable image registration motion fields. To predict the internal patient motion during treatment with only external breathing signal measurements being available, the patients' internal motion information and external breathing signals acquired during 4D CT imaging were correlated. Combining the correspondence model, patient-specific breathing signal measurements during treatment and time-resolved information about dose delivery, reconstruction of a motion variability-affected dose becomes possible. As a proof of concept, the proposed approach is illustrated by a retrospective 4D simulation of VMAT-based SBRT treatment of ten patients with 15 treated lung and liver metastases and known clinical endpoints for the individual metastases (local metastasis recurrence yes/no). Resulting 4D-simulated dose distributions were compared to motion-affected dose distributions estimated by standard 4D CT-only dose accumulation and the originally (i.e. statically) planned dose distributions by means of GTV D-98 indices (dose to 98% of the GTV volume). A potential linkage of metastasis-specific endpoints to differences between GTV D-98 indices of planned and 4D-simulated dose distributions was analyzed.
引用
收藏
页码:9001 / 9017
页数:17
相关论文
共 50 条
  • [41] Simulation of spatiotemporal CT data sets using a 4D MRI-based lung motion model
    Mirko Marx
    Jan Ehrhardt
    René Werner
    Heinz-Peter Schlemmer
    Heinz Handels
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 401 - 409
  • [42] DVH analysis using a transmission detector and model-based dose verification system as a comprehensive pretreatment QA tool for VMAT plans: Clinical experience and results
    Yoosuf, Ahamed B. Mohamed
    AlShehri, Salem
    Alhadab, Abdulrahman
    Alqathami, Mamdooh
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (11): : 80 - 87
  • [43] Supporting constructability analysis meetings with Immersive Virtual Reality-based collaborative BIM 4D simulation
    Boton, Conrad
    AUTOMATION IN CONSTRUCTION, 2018, 96 : 1 - 15
  • [44] 3D Model-Based Simulation Analysis of Energy Consumption in Hot Air Drying of Corn Kernels
    Zhang, Shiwei
    Kong, Ninghua
    Zhu, Yufang
    Zhang, Zhijun
    Xu, Chenghai
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2013, 2013
  • [45] 4D Cone-beam CT reconstruction using a motion model based on principal component analysis
    Staub, David
    Docef, Alen
    Brock, Robert S.
    Vaman, Constantin
    Murphy, Martin J.
    MEDICAL PHYSICS, 2011, 38 (12) : 6697 - 6709
  • [46] 4D log file-based proton dose reconstruction: Fraction-wise interplay analysis in clinical practice
    Spautz, S.
    Thiele, J.
    Tschiche, M.
    Troost, E. G.
    Richter, C.
    Stuetzer, K.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S422 - S423
  • [47] Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm
    Van Uytven, Eric
    Van Beek, Timothy
    McCowan, Peter M.
    Chytyk-Praznik, Krista
    Greer, Peter B.
    McCurdy, Boyd M. C.
    MEDICAL PHYSICS, 2015, 42 (12) : 6945 - 6954
  • [48] Scenario-based 4D dynamic simulation model for in-situ production and yard stock of precast concrete members
    Lim, Jeeyoung
    Son, Chang-Baek
    Kim, Sunkuk
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2023, 22 (04) : 2320 - 2334
  • [49] Spatial Auto-Regressive Analysis of Correlation in 3-D PET With Application to Model-Based Simulation of Data
    Huang, Jian
    Mou, Tian
    O'Regan, Kevin
    O'Sullivan, Finbarr
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (04) : 964 - 974
  • [50] A Dosimetric Analysis of 3D Versus 4D Image-Based Dose Calculation for Stereotactic Body Radiation Therapy in Lung Tumors
    Ma, M.
    Rouabhi, O.
    Bayouth, J.
    Flynn, R.
    Xia, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 203 - 203