Initial osteoblast-like cell response to pure titanium and zirconia/alumina ceramics

被引:65
|
作者
Ko, Hee-Cheol
Han, Jung-Suk [1 ]
Bachle, Maria
Jang, Jun-Hyeog
Shin, Sang-Wan
Kim, Dae-Joon
机构
[1] Korea Univ, Grad Sch, Dept Oral Rehabil, Seoul, South Korea
[2] Seoul Natl Univ, Sch Dent, Dent Res Inst, Dept Prosthodont, Seoul 110749, South Korea
[3] Univ Hosp Freiburg, Sch Dent, Dept Prosthodont, D-79106 Freiburg, Germany
[4] Inha Univ, Coll Med, Dept Biochem, Inchon, South Korea
[5] Sejong Univ, Dept Adv Mat Engn, Seoul, South Korea
关键词
zirconia/alumina ceramic; AFM; osteoblast-like HOS cells; SEM; cell proliferation; RT-PCR;
D O I
10.1016/j.dental.2006.11.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Outstanding mechanical properties, resistance to scratching and high biocompatibility make zirconia/alumina ceramics interesting for dental applications. To solve the problem of the well-known low temperature degradation and to provide stable mechanical properties a novel zirconia alloy ((Y,Nb)-TZP/alumina) was developed. The aim of this study was to investigate the initial bone cell response to this new zirconia/alumina composite ceramic. Methods. HOS cells were cultured on zirconia/alumina composite (Zc) and pure titanium (Ti) discs. Surface topography was examined by atomic force microscopy (AFM), cell morphology by scanning electron microscopy (SEM). Cell proliferation (MTS) and alkaline phosphatase activity was measured at 1, 4 and 8 days. The mRNA expression of Cycline D1, the cell cycle regulating gene, integrin P 1, osteonectin (ON) and P-actin were evaluated by RT-PCR analysis after 12, 24 and 48 h. Results. Both substrates showed a very smooth character with R.-values in the range of 0.002-0.113 mu m supporting a continuous cellular growth. After 8 days, cell proliferation on Zc was higher than onTi. The mRNA expression of cyclin D1 showed similar activity after 48 h on both surfaces, ALP activity was higher on Zc after 8 days. ON expression however showed no difference between the two groups. Significance. Our data demonstrate that this new zirconia composite ceramic showed at least equivalent or slightly better biological response of osteoblast-like HOS cells than pure titanium during a short-time cell culture period. (C) 2006 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1349 / 1355
页数:7
相关论文
共 50 条
  • [41] Beta-Titanium Alloy Covered by Ferroelectric Coating-Physicochemical Properties and Human Osteoblast-Like Cell Response
    Vandrovcova, Marta
    Tolde, Zdenek
    Vanek, Premysl
    Nehasil, Vaclav
    Doubkova, Martina
    Travnickova, Martina
    Drahokoupil, Jan
    Buixaderas, Elena
    Borodavka, Fedir
    Novakova, Jaroslava
    Bacakova, Lucie
    COATINGS, 2021, 11 (02) : 1 - 25
  • [42] Influence of titanium surfaces on attachment of osteoblast-like cells in vitro
    Jayaraman, M
    Meyer, U
    Bühner, M
    Joos, U
    Wiesmann, HP
    BIOMATERIALS, 2004, 25 (04) : 625 - 631
  • [43] The impact of photobiomodulation on osteoblast-like cell: a review
    Deana, Alessandro Melo
    de Souza, Ana Maria
    Teixeira, Victor Perez
    Mesquita-Ferrari, Raquel Agneli
    Bussadori, Sandra Kalil
    Santos Fernandes, Kristianne Porta
    LASERS IN MEDICAL SCIENCE, 2018, 33 (05) : 1147 - 1158
  • [44] Effects of Hydrocarbons Contamination on Initial Responses of Osteoblast-like Cells on Acid-Etched Titanium Surface
    Lu Haibin
    Wan Lei
    Zhang Xueyang
    Rong Mingdeng
    Guo Zehong
    Zhou Lei
    RARE METAL MATERIALS AND ENGINEERING, 2013, 42 (08) : 1558 - 1562
  • [45] Similar inductive effects of enamel and dentin matrix derivatives on osteoblast-like cell response over SLA titanium surface
    Ramenzoni, L. L.
    Hirsiger, C.
    Weber, F. E.
    Attin, T.
    Schmidlin, P. R.
    ARCHIVES OF ORAL BIOLOGY, 2020, 109
  • [46] The impact of photobiomodulation on osteoblast-like cell: a review
    Alessandro Melo Deana
    Ana Maria de Souza
    Victor Perez Teixeira
    Raquel Agneli Mesquita-Ferrari
    Sandra Kalil Bussadori
    Kristianne Porta Santos Fernandes
    Lasers in Medical Science, 2018, 33 : 1147 - 1158
  • [47] Microrough titanium surface affects biologic response in MG63 osteoblast-like cells
    Kim, Myung-Joo
    Kim, Chang-Whe
    Lim, Young-Jun
    Heo, Seong-Joo
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2006, 79A (04) : 1023 - 1032
  • [48] Proteomic analysis of the biological response of MG63 osteoblast-like cells to titanium implants
    Kim, Chang-Su
    Lee, Kee-Joon
    Kim, Jung-Eun
    Park, Yun-Gyu
    Ryu, Jae-Jun
    Kim, Hang-Rae
    ODONTOLOGY, 2014, 102 (02) : 241 - 248
  • [49] Proliferative Response of Different Human Osteoblast-like Cell Models to Proinflammatory Cytokines
    Michael E Harbour
    John W Gregory
    Huw R Jenkins
    Bronwen A J Evans
    Pediatric Research, 2000, 48 : 163 - 168
  • [50] Gap Junctions and Osteoblast-like Cell Gene Expression in Response to Fluid Flow
    Jekir, Michael G.
    Donahue, Henry J.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (01):