X-ray Tomographic Microscopy at TOMCAT

被引:15
|
作者
Marone, F. [1 ]
Hintermueller, C. [1 ]
McDonald, S. [1 ]
Abela, R. [1 ]
Mikuljan, G. [1 ]
Isenegger, A. [1 ]
Stampanoni, M. [1 ]
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
关键词
D O I
10.1088/1742-6596/186/1/012042
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Synchrotron-based X-ray Tomographic Microscopy is a powerful technique for fast non-destructive, high resolution quantitative volumetric investigations on diverse samples. At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline at the Swiss Light Source, synchrotron light is delivered by a 2.9 T superbend. The main optical component, a Double Crystal Multilayer Monochromator, covers an energy range between 8 and 45 keV. The standard TOMCAT detector offers field of views ranging from 0.75x0.75 mm(2) up to 12.1x12.1 mm(2) with a pixel size of 0.37 mu m and 5.92 mu m, respectively. In addition to routine measurements, which exploit the absorption contrast, the high coherence of the source also enables phase contrast tomography, implemented with two complementary techniques (Modified Transport of Intensity approach and Grating Interferometry). Typical acquisition times for a tomogram are in the order of few minutes, ensuring high throughput and allowing for semi-dynamical investigations. Raw data are automatically post-processed online and full reconstructed volumes are available shortly after a scan with minimal user intervention.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] X-ray tomographic microscopy at TOMCAT
    Marone, F.
    Hintermueller, C.
    McDonald, S.
    Abela, R.
    Mikuljan, G.
    Isenegger, A.
    Stampanoni, M.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [2] Present and Future X-ray Tomographic Microscopy at TOMCAT
    Marone, F.
    Mokso, R.
    Modregger, P.
    Fife, J.
    Pinzer, B.
    Thuering, T.
    Mader, K.
    Mikuljan, G.
    Isenegger, A.
    Stampanoni, M.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 116 - 119
  • [3] Synchrotron X-ray tomographic microscopy of fossil embryos
    Philip C. J. Donoghue
    Stefan Bengtson
    Xi-ping Dong
    Neil J. Gostling
    Therese Huldtgren
    John A. Cunningham
    Chongyu Yin
    Zhao Yue
    Fan Peng
    Marco Stampanoni
    Nature, 2006, 442 : 680 - 683
  • [4] X-ray tomographic microscopy at the Swiss Light Source
    Stampanoni, M
    Wyss, P
    Abela, R
    Borchert, G
    Vermeulen, D
    Rüegsegger, P
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 42 - 53
  • [5] Synchrotron X-ray tomographic microscopy of fossil embryos
    Donoghue, Philip C. J.
    Bengtson, Stefan
    Dong, Xi-Ping
    Gostling, Neil J.
    Huldtgren, Therese
    Cunningham, John A.
    Yin, Chongyu
    Yue, Zhao
    Peng, Fan
    Stampanoni, Marco
    NATURE, 2006, 442 (7103) : 680 - 683
  • [6] X-ray tomographic microscopy of natural carious lesions
    Breunig, T
    Marshall, GW
    Kinney, JH
    Haupt, DL
    Marshall, SJ
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 116 - 116
  • [7] Tomographic Hard X-ray Phase Contrast Micro- and Nano-imaging at TOMCAT
    Stampanoni, M.
    Marone, F.
    Modregger, P.
    Pinzer, B.
    Thuering, T.
    Vila-Comamala, J.
    David, C.
    Mokso, R.
    6TH INTERNATIONAL CONFERENCE ON MEDICAL APPLICATIONS OF SYNCHROTRON RADIATION, 2010, 1266 : 13 - +
  • [8] Advantages of phase retrieval for fast x-ray tomographic microscopy
    Mokso, R.
    Marone, F.
    Irvine, S.
    Nyvlt, M.
    Schwyn, D.
    Mader, K.
    Taylor, G. K.
    Krapp, H. G.
    Skeren, M.
    Stampanoni, M.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2013, 46 (49)
  • [9] Variations in dentin mineralization characterized with X-ray tomographic microscopy
    Breunig, T
    Marshall, GW
    Kinney, JH
    Marshall, SJ
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 387 - 387
  • [10] Tomographic observation of integrated circuit based on X-ray microscopy
    Xi, Xiaoqi
    Li, Lei
    Yan, Bin
    Deng, Lin
    Han, Yu
    Zhang, Kai
    AOPC 2015: ADVANCED DISPLAY TECHNOLOGY; AND MICRO/NANO OPTICAL IMAGING TECHNOLOGIES AND APPLICATIONS, 2015, 9672