Synchronous Generator Load Angle Estimation

被引:1
|
作者
Cucek, Hrvoje [1 ]
Sumina, Damir [1 ]
Svigir, Nikola [1 ]
机构
[1] Univ Zagreb, Fac Elect Engn & Comp, Zagreb 41000, Croatia
关键词
D O I
10.1109/MELCON.2010.5476348
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the paper is proposed a load angle estimation method for synchronous generators. The estimation method is based on synchronous generator corresponding voltage-current vector diagram and parameters of generator, transformer and transmission lines. In addition measurement of the load angle is presented. The estimation results were compared with the measured ones. The estimation method gives satisfactory accuracy for load angles less then 120 degrees el. Although the load angle is a key variable for generator stability, it is rarely used as a variable in excitation control system, because the measurement problems. Hence, this estimation method has a wide area of application in excitation systems for control algorithm and to provide stabile work of synchronous generator in capacitive operating area.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [41] Finite Element Method Investigation and Loss Estimation of a Permanent Magnet Synchronous Generator Feeding a Non-Linear Load
    Barmpatza, Alexandra C.
    Kappatou, Joya C.
    ENERGIES, 2018, 11 (12)
  • [42] Synchronous Generator Loss of Field Protection by Using Rotor Angle Variations
    Hasani, Abbas
    Haghjoo, Farhad
    da Silva, Filipe Faria
    Bak, Claus Leth
    2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,
  • [43] Artificial Neural Networks applied to Measurements Rotor Angle in a Synchronous Generator
    Darie, Eleonora
    Cepisca, Costin
    Darie, Emanuel
    COMPUTING AND COMPUTATIONAL INTELLIGENCE, PROCEEDINGS, 2009, : 193 - +
  • [44] Determination of Load Angle for Salient-pole Synchronous Machine
    Sumina, D.
    Sala, A.
    Malaric, R.
    MEASUREMENT SCIENCE REVIEW, 2010, 10 (03): : 89 - 96
  • [45] Study on parameter estimation of hydraulic synchronous generator based on synchronous phasor measurement unit
    Sun, Lixia
    Qu, Ping
    Gao, Yunhua
    Wu, Lei
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 860 - 865
  • [46] Load Angle Control Strategy for Doubly Fed Induction Generator
    Deshpande, A. P.
    Talange, D. B.
    Desai, Kishor S.
    2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL INSTRUMENTATION AND CONTROL (ICIC), 2015, : 1074 - 1077
  • [47] Parameter Estimation of a Synchronous Generator at Moderate Measurement Sampling Rate
    Mitra, Arindam
    Mohapatra, Abheejeet
    Chakrabarti, Saikat
    PROCEEDINGS OF 2019 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE), 2019,
  • [48] Estimation of synchronous generator parameters using an adaptive parameter estimator
    Shakouri, H
    Karrari, M
    Malik, O
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 2253 - 2258
  • [49] ESTIMATION OF SYNCHRONOUS GENERATOR PARAMETERS IN A LARGE SCALE POWER SYSTEM
    Dehghani, Maryam
    Nikravesh, Seyyed Kamaleddin Yadavar
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2009, 5 (08): : 2141 - 2150
  • [50] A NOTE ON HARMONICS IN A SYNCHRONOUS GENERATOR SUPPLYING A SINGLE-PHASE LOAD
    SLATER, RD
    WOOD, WS
    INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING EDUCATION, 1970, 8 (02) : 95 - &