Physiological response of building occupants based on their activity and the indoor environmental quality condition changes

被引:26
|
作者
Kim, Jimin [1 ,2 ]
Kong, Minjin [2 ]
Hong, Taehoon [2 ]
Jeong, Kwangbok [2 ,3 ]
Lee, Minhyun [2 ]
机构
[1] Purdue Univ, Div Construct Engn & Management, W Lafayette, IN 47906 USA
[2] Yonsei Univ, Dept Architecture & Architectural Engn, Seoul 03722, South Korea
[3] Univ Michigan, Dept Civil & Environm Engn, Ann Arbor, MI 48109 USA
基金
新加坡国家研究基金会;
关键词
Physiology response; Work stress; Indoor environmental quality; Human health; Homeostasis; Hypertension; CARBON-DIOXIDE; IMMUNOGLOBULIN-A; CO2; CONCENTRATIONS; OFFICE WORKERS; BLOOD-PRESSURE; HEART-RATE; STRESS; VENTILATION; EXPOSURE; HEALTH;
D O I
10.1016/j.buildenv.2018.09.018
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aimed to analyze the physiological response (i.e., blood pressure) of building occupants based on the 22 subjects' activity and the Indoor environmental quality (IEQ) condition (i.e., carbon dioxide (CO2) concentration and operative temperature) changes. The experiment was designed with three scenarios to simulate the IEQ condition changes. In each scenario, six cognitive tasks that simulate office work were conducted by the subjects to determine their activity that cause work stress. The paired-t test was conducted to analyze the building occupants' physiological response by scenario. As a result, with a low CO2 concentration (below 1000 ppm), the subjects maintained homeostasis well under work stress. It was difficult to maintain homeostasis, however, with a high CO2 concentration (above 2000 ppm): When the subjects were under work stress, they showed different responses compared to those of the seated state. Homeostasis was affected by stress, according to the IEQ condition changes. The unacceptable condition and work stress were particularly dangerous for the hypertensive (i.e., above 140 mmHg systolic blood pressure) subjects. For the maintenance of homeostasis of occupants, a low CO2 concentration (below 1000 ppm) should be kept, and work stress above a certain level should be avoided. The building's mechanical system designer and facility manager can manage the IEQ condition considering the building occupants' physiological responses, which can be used as an IEQ condition management guideline for health.
引用
收藏
页码:96 / 103
页数:8
相关论文
共 50 条
  • [31] Predicted and actual indoor environmental quality: Verification of occupants' behaviour models in residential buildings
    Andersen, Rune K.
    Fabi, Valentina
    Corgnati, Stefano P.
    [J]. ENERGY AND BUILDINGS, 2016, 127 : 105 - 115
  • [32] Integrated task performance score for the building occupants based on the CO2 concentration and indoor climate factors changes
    Hong, Taehoon
    Kim, Jimin
    Lee, Myeonghwi
    [J]. APPLIED ENERGY, 2018, 228 : 1707 - 1713
  • [33] Occupants' satisfaction toward building environmental quality: structural equation modeling approach
    Kamaruzzaman, Syahrul Nizam
    Egbu, C. O.
    Zawawi, Emma Marinie Ahmad
    Abd Karim, Saipol Bari
    Woon, Chen Jia
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2015, 187 (05)
  • [34] Evaluation of Indoor Environmental Quality in a Natural History Building
    Broadwater, Kendra
    Page, Elena
    Burr, Gregory
    [J]. INTERNATIONAL JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2014, 20 (04) : 342 - 342
  • [35] Indoor environmental quality in French dwellings and building characteristics
    Langer, Sarka
    Ramalho, Olivier
    Derbez, Mickael
    Riberon, Jacques
    Kirchner, Severine
    Mandin, Corinne
    [J]. ATMOSPHERIC ENVIRONMENT, 2016, 128 : 82 - 91
  • [36] Postoccupancy indoor environmental quality evaluation of an institutional building
    Rock, Brian A.
    Hillman, Craig A.
    [J]. Journal of Architectural Engineering, 1996, 2 (03) : 88 - 94
  • [37] Occupants’ satisfaction toward building environmental quality: structural equation modeling approach
    Syahrul Nizam Kamaruzzaman
    C. O. Egbu
    Emma Marinie Ahmad Zawawi
    Saipol Bari Abd Karim
    Chen Jia Woon
    [J]. Environmental Monitoring and Assessment, 2015, 187
  • [38] An Investigation of Indoor Environment Quality on Occupants’ Thermal Responses, Health, and Productivity: A Study Based on Physiological Data in Occupied Office Space
    Suryo, Mahatma Sindu
    Ichinose, Masayuki
    Kuroda, Yukino
    Alkhalaf, Haitham
    [J]. Buildings, 2024, 14 (11)
  • [39] An IoT-Based Smart Building Solution for Indoor Environment Management and Occupants Prediction
    Floris, Alessandro
    Porcu, Simone
    Girau, Roberto
    Atzori, Luigi
    [J]. ENERGIES, 2021, 14 (10)
  • [40] Indoor environmental quality in social housing with elderly occupants in Spain: Measurement results and retrofit opportunities
    Serrano-Jimenez, Antonio
    Lizana, Jesus
    Molina-Huelva, Marta
    Barrios-Padura, Angela
    [J]. JOURNAL OF BUILDING ENGINEERING, 2020, 30 (30)