Two-loop-based low-coherence multiplexing fiber-optic sensor network with a Michelson optical path demodulator

被引:0
|
作者
Yuan, LB [1 ]
Yang, J [1 ]
机构
[1] Harbin Engn Univ, Dept Phys, Harbin 150001, Peoples R China
关键词
D O I
10.1364/OL.30.000601
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A two-loop-based low-coherence multiplexing fiber-optic sensor network is proposed and demonstrated. It greatly extends the multiplexing capacity of this kind of sensor. A practical implementation of this scheme uses a popular amplified spontaneous emission light source and standard single-mode fiber, which are commonly used in the communications industry. The sensor's two-loop topology is completely passive. Absolute length measurements can be obtained for each sensing fiber segment for use in measuring the quasidistribution strain or temperature. For large-scale smart structures this technique not only extends the multiplexing potential but also provides a redundancy for the sensing system. This means that the two-loop sensor network can break down at several points and the sensing system will still work even if some of the embedded two-loop sensors have been destroyed. The robustness of the nine-sensor two-loop sensing network is investigated and discussed. (C) 2005 Optical Society of America.
引用
收藏
页码:601 / 603
页数:3
相关论文
共 50 条
  • [41] Fiber-optic Michelson magnetic field sensor based on a mechanical amplifier structure
    Feng, Xinxing
    Jiang, Yi
    Zhang, Han
    APPLIED OPTICS, 2021, 60 (33) : 10359 - 10364
  • [42] Fiber-optic liquid level sensor based on coupling optical path length variation
    Nath, Pabitra
    Singh, Hidam Kumarjit
    Tiwari, Dhananjay
    Basumatry, Tenisen
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (05):
  • [43] Research on an optical-fiber low-coherence interferometric sensing system based on multiplexing interferometric technology
    Li, Zhaoying
    Xie, Fang
    Ma, Sen
    Liu, Yiqin
    Guangxue Xuebao/Acta Optica Sinica, 2012, 32 (06):
  • [44] QUASI-DISTRIBUTED NETWORK OF LOW-COHERENCE FIBER-OPTIC FABRY-PEROT SENSORS WITH CAVITY LENGTH-BASED ADDRESSING
    Karpienko, Katarzyna
    Marzejon, Marcin J.
    Mazikowski, Adam
    Plucinski, Jerzy
    METROLOGY AND MEASUREMENT SYSTEMS, 2021, 28 (02) : 289 - 305
  • [45] Inline liquid concentration measurement in nanoliter volume using fiber-optic low-coherence interferometry
    Tomic, Milos C.
    Djinovic, Zoran V.
    IEEE SENSORS JOURNAL, 2008, 8 (5-6) : 587 - 592
  • [46] Gradient-index fiber-optic microprobes for minimally invasive in vivo low-coherence interferometry
    Reed, WA
    Yan, MF
    Schnitzer, MJ
    OPTICS LETTERS, 2002, 27 (20) : 1794 - 1796
  • [47] Fiber-optic low-coherence tomography system for visualization of internal structure of ceramic materials.
    Jedrzejewska-Szczerska, M
    Strakowski, M
    Hypszer, R
    Kosmowski, BB
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS IV, 2006, 6159
  • [48] Low-Coherence Homodyne Interferometer for Sub-Megahertz Fiber Optic Sensor Readout
    Volkov, Petr
    Lukyanov, Andrey
    Goryunov, Alexander
    Semikov, Daniil
    Vyazankin, Oleg
    SENSORS, 2024, 24 (02)
  • [49] Enhancement of fiber-optic low-coherence Fabry-Perot interferometer with ZnO ALD films
    Hirsch, Marzena
    Listewnik, Paulina
    Jedrzejewska-Szczerska, Malgorzata
    SARATOV FALL MEETING 2017: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE XIX, 2018, 10716
  • [50] High sensitivity fiber-optic Michelson interferometric low-frequency acoustic sensor based on a gold diaphragm
    Fan, Pingjie
    Yan, Wei
    Lu, Ping
    Zhang, Wanjin
    Zhang, Wei
    Fu, Xin
    Zhang, Jiangshan
    OPTICS EXPRESS, 2020, 28 (17) : 25238 - 25249