Health economic assessment of Gd-EOB-DTPA MRI versus ECCM-MRI and multi-detector CT for diagnosis of hepatocellular carcinoma in China

被引:18
|
作者
He, Xiaoning [1 ]
Wu, Jing [1 ]
Holtorf, Anke-Peggy [2 ]
Rinde, Harald [2 ]
Xie, Shuangshuang [3 ]
Shen, Wen [3 ]
Hou, Jiancun [4 ]
Li, Xuehua [5 ]
Li, Ziping [5 ]
Lai, Jiaming [6 ]
Wang, Yuting [7 ]
Zhang, Lin [7 ]
Wang, Jian [7 ]
Li, Xuesong [8 ]
Ma, Kuansheng [8 ]
Ye, Feng [9 ]
Ouyang, Han [9 ]
Zhao, Hong [10 ]
机构
[1] Tianjin Univ, Sch Pharmaceut Sci & Technol, Dept Hlth & Pharm Adm, Tianjin, Peoples R China
[2] Hlth Outcomes Strategies, Basel, Switzerland
[3] Tianjin First Ctr Hosp, Dept Radiol, Tianjin, Peoples R China
[4] Tianjin First Ctr Hosp, Dept Hepatobiliary Surg, Tianjin, Peoples R China
[5] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Radiol, Guangzhou, Guangdong, Peoples R China
[6] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Hepatobiliary Surg, Guangzhou, Guangdong, Peoples R China
[7] Southwestern Hosp, Dept Radiol, Chongqing, Peoples R China
[8] Southwestern Hosp, Dept Hepatobiliary Surg, Chongqing, Peoples R China
[9] Chinese Acad Med Sci, Canc Hosp, Dept Radiol, Beijing, Peoples R China
[10] Chinese Acad Med Sci, Canc Hosp, Dept Hepatobiliary Surg, Beijing, Peoples R China
来源
PLOS ONE | 2018年 / 13卷 / 01期
关键词
LIVER-LESIONS; ENHANCED MRI; MDCT; PERFORMANCE; GADOLINIUM; NODULES; SMALLER;
D O I
10.1371/journal.pone.0191095
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Limited data exists in China on the comparative cost of gadolinium ethoxybenzyl diethylenetriamine magnetic resonance imaging (Gd-EOB-DTPA-MRI) with other imaging techniques. This study compared the total cost of Gd-EOB-DTPA-MRI with multidetector computed tomography (MDCT) and extracellular contrast media-enhanced MRI (ECCM-MRI) as initial imaging procedures in patients with suspected hepatocellular carcinoma (HCC). We developed a decision-tree model on the basis of the Chinese clinical guidelines for HCC, which was validated by clinical experts from China. The model compared the diagnostic accuracy and costs of alternative initial imaging procedures. Compared with MDCT and ECCM-MRI, Gd-EOB-DTPA-MRI imaging was associated with higher rates of diagnostic accuracy, i.e. higher proportions of true positives (TP) and true negatives (TN) with lower false positives (FP). Total diagnosis and treatment cost per patient after the initial Gd-EOB-DTPA-MRI evaluation was similar to MDCT ((sic) 30,360 vs. (sic) 30,803) and lower than that reported with ECCM-MRI ((sic) 30,360 vs. (sic) 31,465). Lower treatment cost after initial Gd-EOB-DTPA-MRI was driven by reduced utilization of confirmatory diagnostic procedures and unnecessary treatments. The findings reported that Gd-EOB-DTPA-MRI offered higher diagnostic accuracy compared with MDCT and ECCM-MRI at a comparable cost, which indicates Gd-EOBDTPA-MRI could be the preferred initial imaging procedure for the diagnosis of HCC in China.
引用
收藏
页数:14
相关论文
共 46 条
  • [41] Is 3-Tesla Gd-EOB-DTPA-Enhanced MRI with Diffusion-Weighted Imaging Superior to 64-Slice Contrast-Enhanced CT for the Diagnosis of Hepatocellular Carcinoma?
    Maiwald, Bettina
    Lobsien, Donald
    Kahn, Thomas
    Stumpp, Patrick
    PLOS ONE, 2014, 9 (11):
  • [42] Gd-EOB-DTPA-enhanced 3.0-Tesla MRI findings for the preoperative detection of focal liver lesions: Comparison with iodine-enhanced multi-detector computed tomography
    Park, Hyong-Hu
    Goo, Eun-Hoe
    Im, In-Chul
    Lee, Jae-Seung
    Kim, Moon-Jib
    Kwak, Byung-Joon
    Chung, Woon-Kwan
    Dong, Kyung-Rae
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (11) : 1866 - 1876
  • [43] Gd-EOB-DTPA-enhanced 3.0-Tesla MRI findings for the preoperative detection of focal liver lesions: Comparison with iodine-enhanced multi-detector computed tomography
    Hyong-Hu Park
    Eun-Hoe Goo
    In-Chul Im
    Jae-Seung Lee
    Moon-Jib Kim
    Byung-Joon Kwak
    Woon-Kwan Chung
    Kyung-Rae Dong
    Journal of the Korean Physical Society, 2012, 61 : 1866 - 1876
  • [44] Radiation-induced Liver Injury after 3D-conformal Radiotherapy for Hepatocellular Carcinoma: Quantitative Assessment Using Gd-EOB-DTPA-enhanced MRI
    Fukugawa, Yoshiyuki
    Namimoto, Tomohiro
    Toya, Ryo
    Saito, Tetsuo
    Yuki, Hideaki
    Matsuyama, Tomohiko
    Ikeda, Osamu
    Yamashita, Yasuyuki
    Oya, Natsuo
    ACTA MEDICA OKAYAMA, 2017, 71 (01) : 25 - 29
  • [45] DIAGNOSTIC SENSITIVITY FOR HEPATOCELLULAR CARCINOMA WITH GD-EOB-DTPA-ENHANCED LIVER MRI AND SONAZOID CONTRAST-ENHANCED ULTRASOUND: COMPARISON WITH 64-SLICE MULTIDETECTOR HELICAL CT
    Ma, J.
    Onodera, Y.
    Nishida, M.
    Kamishima, T.
    Shirato, H.
    Loo, W.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S1 - S2
  • [46] Comparison of 18F-FDG PET-CT and Gd-EOB-DTPA-enhanced MRI for prediction of microvascular invasion and outcome after curative resection for early-stage hepatocellular carcinoma
    Kobayashi, Tomoki
    Aikata, Hiroshi
    Daijo, Kana
    Teraoka, Yuji
    Nakamura, Yuki
    Nagaoki, Kei Morio Yuko
    Kawaoka, Tomokazu
    Tsuge, Masataka
    Hiramatsu, Akira
    Imamura, Michio
    Kawakami, Yoshiiku
    Chayama, Kazuaki
    HEPATOLOGY, 2016, 64 : 218A - 218A