Ground Calibration of the Silicon Drift Detectors for NICER

被引:17
|
作者
LaMarr, Beverly [1 ]
Prigozhin, Gregory [1 ]
Remillard, Ronald [1 ]
Malonis, Andrew [1 ]
Gendreau, Keith C. [2 ]
Arzoumanian, Zaven [2 ]
Markwardt, Craig B. [2 ]
Baumgartner, Wayne H. [2 ]
机构
[1] MIT, Kavli Inst Astrophys, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[2] NASA, Goddard Space Flight Ctr, Greenbelt, MD USA
来源
SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY | 2016年 / 9905卷
关键词
Silicon Drift Detectors; X-rays; timing spectroscopy; calibration;
D O I
10.1117/12.2232784
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Neutron star Interior Composition ExploreR (NICER) is set to be deployed on the International Space Station (ISS) in early 2017. It will use an array of 56 Silicon Drift Detectors (SDDs) to detect soft X-rays (0.2 - 12 keV) with 100 nanosecond timing resolution. Here we describe the effort to calibrate the detectors in the lab primarily using a Modulated X-ray Source (MXS). The MXS that was customized for NICER provides more than a dozen emission lines spread over the instrument bandwidth, providing calibration measurements for detector gain and spectral resolution. In addition, the fluorescence source in the MXS was pulsed at high frequency to enable measurement of the delay due to charge collection in the silicon and signal processing in the detector electronics. A second chamber, designed to illuminate detectors with either Fe-55, an optical LED, or neither, provided additional calibration of detector response, optical blocking, and effectiveness of background rejection techniques. The overall ground calibration achieved total operating time that was generally in the range of 500-1500 hours for each of the 56 detectors.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Probe station for testing of ALICE silicon drift detectors
    Humanic, TJ
    Kotov, IV
    Piemonte, C
    Rashevsky, A
    Sugarbaker, E
    Vacchi, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 512 (1-2): : 272 - 276
  • [32] Novel high-resolution silicon drift detectors
    Lechner, P
    Pahlke, A
    Soltau, H
    X-RAY SPECTROMETRY, 2004, 33 (04) : 256 - 261
  • [33] EFFECTIVE THICKNESS OF DEAD LAYER OF SILICON DRIFT DETECTORS
    PODENKO, NP
    STEPANOV, EK
    MEASUREMENT TECHNIQUES-USSR, 1971, 14 (09): : 1457 - &
  • [34] Efficiency analysis and promising applications of silicon drift detectors
    Khreptak, Aleksander
    Skurzok, Magdalena
    BIO-ALGORITHMS AND MED-SYSTEMS, 2023, 19 (01) : 74 - 79
  • [35] A compact Compton polarimeter utilizing silicon drift detectors
    They, J
    Buschhorn, G
    Kotthaus, R
    Morokhovskii, VL
    Pugachev, D
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS IV, 2000, 4138 : 193 - 202
  • [36] Silicon drift detectors for the STAR/SVT experiment at RHIC
    Takahashi, J
    Bellwied, R
    Beuttenmuller, R
    Caines, H
    Chen, W
    DiMassimo, D
    Dyke, H
    Elliot, D
    Grau, M
    Hoffmann, GW
    Humanic, T
    Jensen, P
    Kotov, IV
    Kraner, HW
    Kuczewski, P
    Leonhardt, W
    Li, Z
    Liaw, C
    LoCurto, G
    Lynn, D
    Mazeh, N
    Middelkamp, P
    Minor, R
    Nehmeh, S
    Ott, G
    Pandey, SU
    Pinelli, D
    Pruneau, C
    Rykov, VL
    Schambach, J
    Sedlmeir, J
    Sheen, J
    Soja, R
    Stefani, D
    Sugarbaker, E
    Wilson, WK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 439 (2-3): : 497 - 506
  • [37] Charge collection in the Silicon Drift Detectors of the ALICE experiment
    Alessandro, B.
    Bala, R.
    Batigne, G.
    Beole, S.
    Biolcati, E.
    Cerello, P.
    Coli, S.
    Corrales Morales, Y.
    Crescio, E.
    De Remigis, P.
    Falchieri, D.
    Giraudo, G.
    Giubellino, P.
    Lea, R.
    Chiesa, A. Marzari
    Masera, M.
    Mazza, G.
    Ortona, G.
    Prino, F.
    Ramello, L.
    Rashevsky, A.
    Riccati, L.
    Rivetti, A.
    Senyukov, S.
    Siciliano, M.
    Sitta, M.
    Subieta, M.
    Toscano, L.
    Tosello, F.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [38] Radiation damage studies with STAR silicon drift detectors
    Takahashi, J.
    Bellwied, R.
    Beuttenmueller, R.
    Chen, W.
    Dezillie, B.
    Eremin, V.
    Elliot, D.
    Hoffmann, G.W.
    Huang, W.
    Humanic, T.
    Ilyashenko, I.
    Kotov, I.V.
    Kuczewski, P.
    Leonhardt, W.
    Li, Z.
    et. al.
    2000, IEEE, Piscataway, NJ, United States (47)
  • [39] The read-out ASIC for silicon drift detectors
    Atkin, E.
    Ivanov, P.
    Krivchenko, A.
    Levin, V.
    Gusev, A.
    Malankin, E.
    Normanov, D.
    Rotin, A.
    Sagdiev, I.
    Shumikhin, V.
    INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS (ICPPA-2015), PTS 1-4, 2016, 675
  • [40] Silicon drift detectors with integrated JFET: Simulation and design
    Mehta, P
    Mishra, V
    Kataria, SK
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2005, 43 (09) : 705 - 713