Haemodynamics of an iatrogenic atrial septal defect after MitraClip implantation

被引:9
|
作者
Eden, Matthias [1 ]
Leeb, Leonhard [1 ]
Frey, Norbert [1 ]
Rosenberg, Mark [1 ,2 ]
机构
[1] Univ Klinikum Schleswig Holstein, Innere Med 3, Kiel, Germany
[2] Klinikum Aschaffenburg Alzenau, Med Klin 1, Hasenkopf 1, D-63739 Aschaffenburg, Germany
关键词
Iatrogenic septal defect; left atrial decompression; left-to-right shunt; MitraClip; LEFT-TO-RIGHT; VALVE REPAIR; PERCUTANEOUS REPAIR; EJECTION FRACTION; HEART-FAILURE; REGURGITATION; ECHOCARDIOGRAPHY; MULTICENTER; SURGERY; SHUNT;
D O I
10.1111/eci.13295
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The MitraClip procedure requires transseptal access of the left atrium with a 24F guiding sheath. We evaluated invasively whether a MitraClip induced iatrogenic atrial septal defect (IASD) leads to development of a relevant interatrial shunt and right ventricular overload. Methods A total of 69 patients who underwent a MitraClip procedure due to a severe mitral valve regurgitation (MVR) were included in the observational, retrospective cohort study. All pressures were directly measured throughout the procedure. Cardiac index (CI), systemic (Qs) and pulmonary (Qp) flow were calculated using the Fick method. Results Successful MitraClip implantation increased CI (2.5 +/- 0.62 vs 3.05 +/- 0.77 L/min/m(2);P < .0001), whereas SVR (1491 +/- 474 vs 997 +/- 301 dyn s/cm(5);P < .0001), PVR (226 +/- 121 vs 188 +/- 96 dyn/s/cm(5);P = .04), PCWP (23 +/- 6.1 vs 20 +/- 4.7 mm Hg;P = .0031), PA pressure (33.6 +/- 7.2 vs 31.9 +/- 6.6 mm Hg;P = .1437) and LA pressure (21.5 +/- 5.4 vs 18.7 +/- 4.9 mm Hg;P < .0001) all decreased. The effect on LA pressure was further enhanced by guiding catheter retrieval (14.4 +/- 4.6 mm Hg;P < .0001). At the end of the procedure, Qp (6.033 +/- 1.3 L/min) exceeded Qs (5.537 +/- 1.3 L/min) by 0.496 L/min leading to a Qp:Qs ratio of 1.09 (P = .007). After 6 months, echocardiography revealed no changes in RV diameter (42.96 +/- 6.95 mm vs 43.81 +/- 7.67 mm;P = .62) and TAPSE (17.13 +/- 3.33 mm vs 17.36 +/- 3.24 mm;P = .48). Conclusion Our data show that the MitraClip procedure does not induce a relevant interatrial shunt or right ventricular overload. In fact, future studies will have to show whether the IASD may even be beneficial in selected patient populations by left atrial volume and pressure relief.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Iatrogenic atrial septal defect after HotBalloon ablation of atrial fibrillation
    Nakamura, Yoshinori
    Sohara, Hiroshi
    Ihara, Minoru
    [J]. HEART AND VESSELS, 2022, 37 (08) : 1418 - 1424
  • [22] EVALUATION OF IATROGENIC ATRIAL SEPTAL DEFECT CLOSURE AFTER TEER
    Manni, Giulia
    Macrini, Massimiliano
    Idone, Gaetano
    Lecis, Dalgisio
    Marchei, Massimo
    Di Landro, Alessio
    Marsili, Giorgia
    Illuminato, Federica
    Galluccio, Chiara
    Oro, Pietro
    Minasi, Vincenzo
    Muscoli, Saverio
    Barilla, Francesco
    [J]. EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24
  • [23] A large iatrogenic tearing of atrial septal defect after MitraClip implantation: a rare and cautionary complication during transcatheter edge-to-edge mitral valve repair
    Masumoto, Akiko
    Yamamoto, Hiroyuki
    Takahashi, Nobuyuki
    Takaya, Tomofumi
    [J]. EUROPEAN HEART JOURNAL-CASE REPORTS, 2022, 6 (04)
  • [24] Delayed iatrogenic atrial septal defect after implantation of a bicaval prosthesis device for the treatment of tricuspid regurgitation
    Arteagoitia-Bolumburu, Ander
    Garcia-Sebastian, Cristina
    Carrion-Sanchez, Irene
    Sanchez-Recalde, Angel
    Fernandez-Golfin, Covadonga
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024,
  • [25] Iatrogenic Atrial Septal Defect After Percutaneous Mitral Valve Repair With MitraClip: Should We Consider Closing Them Routinely?
    Gonzalvez-Garcia, Ariana
    Jurado-Roman, Alfonso
    Hernandez-Matamoros, Harold
    Jimenez-Valero, Santiago
    Galeote, Guillermo
    Moreno, Raul
    Luis Lopez-Sendon, Jose
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 2020, 32 (11): : E295 - E297
  • [26] Prevalence and echocardiographic features of iatrogenic atrial septal defect after catheter-based mitral valve repair with the mitraclip system
    Smith, Thomas
    McGinty, Patrick
    Bommer, William
    Low, Reginald I.
    Lim, Scott
    Fail, Peter
    Rogers, Jason H.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (04) : 678 - 685
  • [27] Iatrogenic Atrial Septal Defect After Cryoballoon Pulmonary Vein Isolation
    Miyazaki, Shinsuke
    Iwasawa, Jin
    Kuroi, Akio
    Iesaka, Yoshito
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (09) : 1021 - 1021
  • [28] Persistent iatrogenic atrial septal defect after pulmonary vein isolation
    Rillig, Andreas
    Meyerfeldt, Udo
    Birkemeyer, Ralf
    Treusch, Fabian
    Kunze, Markus
    Jung, Werner
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 22 (03) : 177 - 181
  • [29] Iatrogenic atrial septal defect: reassurance or inquisitiveness
    Niyada Naksuk
    Samuel J. Asirvatham
    [J]. Journal of Interventional Cardiac Electrophysiology, 2018, 52 : 137 - 140
  • [30] Iatrogenic atrial septal defect: reassurance or inquisitiveness
    Naksuk, Niyada
    Asirvatham, Samuel J.
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 52 (02) : 137 - 140