An FMEA evaluation of intensity modulated radiation therapy dose delivery failures at tolerance criteria levels

被引:14
|
作者
Faught, Jacqueline Tonigan [1 ,2 ,3 ]
Balter, Peter A. [1 ]
Johnson, Jennifer L. [1 ]
Kry, Stephen F. [2 ]
Court, Laurence E. [1 ]
Stingo, Francesco C. [4 ,5 ]
Followill, David S. [2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, IROC Houston QA Ctr, Houston, TX 77030 USA
[3] St Jude Childrens Res Hosp, Dept Radiat Oncol, Memphis, TN 38105 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Biostat, Houston, TX 77030 USA
[5] Univ Florence, Dept Stat, Comp, Applicat, I-50121 Florence, Italy
关键词
FMEA; IMRT; quality assurance; radiation therapy; risk; QUALITY-ASSURANCE; MODE;
D O I
10.1002/mp.12551
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe objective of this work was to assess both the perception of failure modes in Intensity Modulated Radiation Therapy (IMRT) when the linac is operated at the edge of tolerances given in AAPM TG-40 (Kutcher et al.) and TG-142 (Klein et al.) as well as the application of FMEA to this specific section of the IMRT process. MethodsAn online survey was distributed to approximately 2000 physicists worldwide that participate in quality services provided by the Imaging and Radiation Oncology Core - Houston (IROC-H). The survey briefly described eleven different failure modes covered by basic quality assurance in step-and-shoot IMRT at or near TG-40 (Kutcher et al.) and TG-142 (Klein et al.) tolerance criteria levels. Respondents were asked to estimate the worst case scenario percent dose error that could be caused by each of these failure modes in a head and neck patient as well as the FMEA scores: Occurrence, Detectability, and Severity. Risk probability number (RPN) scores were calculated as the product of these scores. Demographic data were also collected. ResultsA total of 181 individual and three group responses were submitted. 84% were from North America. Most (76%) individual respondents performed at least 80% clinical work and 92% were nationally certified. Respondent medical physics experience ranged from 2.5 to 45 yr (average 18 yr). A total of 52% of individual respondents were at least somewhat familiar with FMEA, while 17% were not familiar. Several IMRT techniques, treatment planning systems, and linear accelerator manufacturers were represented. All failure modes received widely varying scores ranging from 1 to 10 for occurrence, at least 1-9 for detectability, and at least 1-7 for severity. Ranking failure modes by RPN scores also resulted in large variability, with each failure mode being ranked both most risky (1st) and least risky (11th) by different respondents. On average MLC modeling had the highest RPN scores. Individual estimated percent dose errors and severity scores positively correlated (P < 0.01) for each FM as expected. No universal correlations were found between the demographic information collected and scoring, percent dose errors or ranking. ConclusionsFailure modes investigated overall were evaluated as low to medium risk, with average RPNs less than 110. The ranking of 11 failure modes was not agreed upon by the community. Large variability in FMEA scoring may be caused by individual interpretation and/or experience, reflecting the subjective nature of the FMEA tool.
引用
收藏
页码:5575 / 5583
页数:9
相关论文
共 50 条
  • [1] An FMEA Survey of Intensity Modulated Radiation Therapy (IMRT) Step and Shoot Dose Delivery Failure Modes
    Faught, J. Tonigan
    Johnson, J.
    Stingo, F.
    Kry, S.
    Court, L.
    Balter, P.
    Followill, D.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3355 - 3355
  • [2] Increasing dose delivery efficiency and reproducibility with static intensity modulated radiation therapy
    Wu, A
    Kalnicki, S
    Chen, A
    Brown, D
    Burton, SA
    Scicutella, C
    [J]. RADIOLOGY, 1998, 209P : 397 - 398
  • [3] Impact of Weight Change on Dose Delivery in Pancreatic Intensity Modulated Radiation Therapy
    Chu, K.
    Eccles, C. L.
    Warren, S.
    Brunner, T. B.
    Mukherjee, S.
    Hawkins, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S862 - S863
  • [4] Evaluation of bladder dose in intensity-modulated radiation therapy of the prostate
    Higgins, P. D.
    Weaver, R.
    Dusenbery, K. E.
    [J]. MEDICAL DOSIMETRY, 2006, 31 (03) : 197 - 200
  • [5] Evaluation criteria for film based intensity modulated radiation therapy quality assurance
    Anjum, Muhammad Naeem
    Parker, William
    Ruo, Russell
    Afzal, Muhammad
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2010, 26 (01): : 38 - 43
  • [6] Alternative methods for intensity-modulated radiation therapy inverse planning and dose delivery
    Galvin, James M.
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2006, 16 (04) : 218 - 223
  • [7] Evaluation of dose uniformity with forward intensity modulated radiation therapy in breast cancer
    Chu, S
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1886 - 1886
  • [8] Planning and delivery of intensity-modulated radiation therapy
    Yu, Cedric X.
    Amies, Christopher J.
    Svatos, Michelle
    [J]. MEDICAL PHYSICS, 2008, 35 (12) : 5233 - 5241
  • [9] Surface dose measurements for intensity modulated radiation therapy
    Mitchell, M. J.
    Ramsey, C.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2249 - 2249
  • [10] Patterns of Prescription and Dose Delivery in 3D Conformal and Intensity Modulated Radiation Therapy
    Das, I. J.
    Srivastva, S. P.
    Hanlon, A.
    Cheng, C. W.
    Jones, A. O.
    Mihailidis, D. N.
    Pai, S.
    Taylor, M. S.
    Wuu, C. S.
    Johnstone, P. A. S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S646 - S647