Diagnostic Accuracy of a Hand-Held Ultrasound Scanner in Routine Patients Referred for Echocardiography

被引:154
|
作者
Prinz, Christian [1 ,2 ]
Voigt, Jens-Uwe [1 ]
机构
[1] Catholic Univ Louvain, Dept Cardiol, Univ Hosp Gasthuisberg, B-3000 Louvain, Belgium
[2] Ruhr Univ Bochum, Dept Cardiol, Heart Ctr N Rhine Westphalia, Bad Oeynhausen, Germany
关键词
Hand-held ultrasound scanner; Echocardiography; Image quality; Vscan; LEFT-VENTRICULAR HYPERTROPHY; POCKET ECHOCARDIOGRAPH; CARRIED ULTRASOUND; FEASIBILITY; EXPERIENCE; PHYSICIANS; DEVICE; ECHO;
D O I
10.1016/j.echo.2010.10.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to investigate the imaging capabilities of recent hand-held ultrasound scanners. Methods: Three hundred forty-nine patients were scanned with hand-held ultrasound (HAND) and high-end echocardiography (HIGH). Segmental endocardial border delineation was scored (2 = good, 1 = poor, 0 = invisible) to describe image quality. Assessments of left ventricular (LV) dimensions, regional and global LV function, and grades of valve disease were compared. Results: The mean endocardial visibility grades were 1.6 +/- 0.5 with HAND and 1.7 +/- 0.4 with HIGH (P <.01). Regional wall motion was scored very similarly (kappa = 0.73, P <.01). Ejection fraction assessment (bias = 1.8%, 1.96 x SD = 8.3%) and LV measurements (r = 0.99, P <.01; interventricular septum: bias = 0.91 mm, 1.96 x SD = 2.1 mm; LV end-diastolic diameter: bias = 0.5 mm, 1.96 x SD = 4.1 mm; LV posterior wall: bias = 0.61 mm, 1.96 x SD = 2.4 mm) showed negligible deviations. No pericardial effusion or valve stenosis was missed. Regurgitations missed by HAND were all graded "minimal'' on HIGH. Regurgitations were mildly overestimated by HAND. Overall concordance for detection of regurgitations was very good (kappa = 0.9, P <.01). Conclusions: Handheld echocardiography was feasible and missed no relevant findings. Given the future implementation of spectral Doppler capabilities, this handheld scanner can safely be used in clinical routine. (J Am Soc Echocardiogr 2011; 24: 111-6.)
引用
收藏
页码:111 / 116
页数:6
相关论文
共 50 条
  • [21] Generation iUltrasound: Bedside diagnostic imaging with Hand-Held Cardiac Ultrasound
    Johri, Amer M.
    CARDIOLOGY JOURNAL, 2014, 21 (01) : 98 - 99
  • [22] Comparing the Accuracy of Hand-Held Ultrasound vs Traditional Ultrasound in Identifying Hepatic Steatosis
    Bath, Harjot
    Chao, Peter
    Chhoda, Ankit
    Sekhon, Sandeep
    Sawhney, Mandeep
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2023, 118 (10): : S1035 - S1035
  • [23] Diagnostic capability and therapeutic impact of hand-held echocardiography in critically ill patient
    Vignon, P
    Chastagner, C
    Francois, B
    Gastinne, H
    INTENSIVE CARE MEDICINE, 2002, 28 : S53 - S53
  • [24] Hand-held echocardiography: its use and usefulness
    Mondillo, Sergio
    Giannotti, Giovanna
    Innelli, Pasquale
    Ballo, Pier Carlo
    Galderisi, Maurizio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 111 (01) : 1 - 5
  • [25] Hand-Held Echocardiography in the Management of Cardiac Arrest
    Oren-Grinberg, Achikam
    Gulati, Gaurav
    Fuchs, Lior
    Pinto, Duane S.
    ANESTHESIA AND ANALGESIA, 2012, 115 (05): : 1038 - 1041
  • [26] Perspectives and Challenges of hand-held Ultrasound
    Dietrich, Christoph F.
    Bulla, Peter
    Dudwiesus, Heiko
    Lo, Hendra
    Hocke, Michael
    Hoffmann, Beatrice
    Horn, Rudolf
    Lehmann, Beat
    Morf, Susanne
    Nuernberg, Dieter
    Prosch, Helmut
    Serra, Andreas
    Spengler, Joerg
    Blaskova, Andrea
    Jenssen, Christian
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2023, 61 (07): : 836 - 851
  • [27] Usefulness of hand-held echocardiography in emergency room
    Leta, R
    Carreras, F
    Borrás, X
    Planas, F
    Pujadas, S
    Pons-Lladó, G
    MEDICINA CLINICA, 2003, 121 (05): : 178 - 180
  • [28] Feasibility and clinical implementation of hand-held echocardiography
    Dalen, Havard
    Haugen, Bjorn Olav
    Graven, Torbjorn
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2013, 11 (01) : 49 - 54
  • [29] SPRAY COVERAGE ANALYSIS USING A HAND-HELD SCANNER
    FRANZ, E
    TRANSACTIONS OF THE ASAE, 1993, 36 (05): : 1271 - 1278
  • [30] Cancer screening - Amazing claims for hand-held scanner
    Pistoi, S
    NEW SCIENTIST, 2003, 178 (2399) : 15 - 15