Diagnostic Accuracy of a Hand-Held Ultrasound Scanner in Routine Patients Referred for Echocardiography

被引:154
|
作者
Prinz, Christian [1 ,2 ]
Voigt, Jens-Uwe [1 ]
机构
[1] Catholic Univ Louvain, Dept Cardiol, Univ Hosp Gasthuisberg, B-3000 Louvain, Belgium
[2] Ruhr Univ Bochum, Dept Cardiol, Heart Ctr N Rhine Westphalia, Bad Oeynhausen, Germany
关键词
Hand-held ultrasound scanner; Echocardiography; Image quality; Vscan; LEFT-VENTRICULAR HYPERTROPHY; POCKET ECHOCARDIOGRAPH; CARRIED ULTRASOUND; FEASIBILITY; EXPERIENCE; PHYSICIANS; DEVICE; ECHO;
D O I
10.1016/j.echo.2010.10.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to investigate the imaging capabilities of recent hand-held ultrasound scanners. Methods: Three hundred forty-nine patients were scanned with hand-held ultrasound (HAND) and high-end echocardiography (HIGH). Segmental endocardial border delineation was scored (2 = good, 1 = poor, 0 = invisible) to describe image quality. Assessments of left ventricular (LV) dimensions, regional and global LV function, and grades of valve disease were compared. Results: The mean endocardial visibility grades were 1.6 +/- 0.5 with HAND and 1.7 +/- 0.4 with HIGH (P <.01). Regional wall motion was scored very similarly (kappa = 0.73, P <.01). Ejection fraction assessment (bias = 1.8%, 1.96 x SD = 8.3%) and LV measurements (r = 0.99, P <.01; interventricular septum: bias = 0.91 mm, 1.96 x SD = 2.1 mm; LV end-diastolic diameter: bias = 0.5 mm, 1.96 x SD = 4.1 mm; LV posterior wall: bias = 0.61 mm, 1.96 x SD = 2.4 mm) showed negligible deviations. No pericardial effusion or valve stenosis was missed. Regurgitations missed by HAND were all graded "minimal'' on HIGH. Regurgitations were mildly overestimated by HAND. Overall concordance for detection of regurgitations was very good (kappa = 0.9, P <.01). Conclusions: Handheld echocardiography was feasible and missed no relevant findings. Given the future implementation of spectral Doppler capabilities, this handheld scanner can safely be used in clinical routine. (J Am Soc Echocardiogr 2011; 24: 111-6.)
引用
收藏
页码:111 / 116
页数:6
相关论文
共 50 条
  • [1] A hand-held, high frequency ultrasound scanner
    Erickson, S
    Kruse, D
    Ferrara, K
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1465 - 1468
  • [2] HAND-HELD ECHOCARDIOGRAPHY IS VASTLY SUPERIOR TO PHYSICAL EXAMINATION BY CARDIOLOGISTS IN PATIENTS REFERRED FOR ECHOCARDIOGRAPHY
    Mehta, Manish
    Jacobson, Timothy
    Peters, Dawn
    Le, Dai-Trang
    Belcik, Todd
    Kaul, Sanjiv
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1083 - E1083
  • [3] THE ACCURACY OF A HAND-HELD REAL-TIME ULTRASOUND SCANNER FOR ESTIMATING BLADDER VOLUME
    RAVICHANDRAN, G
    FELLOWS, GJ
    BRITISH JOURNAL OF UROLOGY, 1983, 55 (01): : 25 - 27
  • [4] Diagnostic ability of hand-held echocardiography in ventilated critically ill patients
    Philippe Vignon
    Catherine Chastagner
    Bruno François
    Jean-François Martaillé
    Sandrine Normand
    Michel Bonnivard
    Hervé Gastinne
    Critical Care, 7
  • [5] Diagnostic ability of hand-held echocardiography in ventilated critically ill patients
    Vignon, P
    Chastagner, C
    François, B
    Martaillé, JF
    Normand, S
    Bonnivard, M
    Gastinne, H
    CRITICAL CARE, 2003, 7 (05): : R84 - R91
  • [6] Evaluation of ultrasound lung comets by hand-held echocardiography
    Bedetti G.
    Gargani L.
    Corbisiero A.
    Frassi F.
    Poggianti E.
    Mottola G.
    Cardiovascular Ultrasound, 4 (1)
  • [7] HAND-HELD CANCER SCANNER
    Cohen, Neil
    MECHANICAL ENGINEERING, 2018, 140 (02) : 10 - 11
  • [8] DIRECT CONTACT, HAND-HELD, DIAGNOSTIC B-SCANNER
    HOLASEK, E
    SOKOLLU, A
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1973, SU20 (01): : 49 - &
  • [9] Nanobubble Mediated Gene Delivery in Conjunction With a Hand-Held Ultrasound Scanner
    Kida, Hiroshi
    Nishimura, Koyo
    Ogawa, Koki
    Watanabe, Akiko
    Feril, Loreto B.
    Irie, Yutaka
    Endo, Hitomi
    Kawakami, Shigeru
    Tachibana, Katsuro
    FRONTIERS IN PHARMACOLOGY, 2020, 11
  • [10] Hand-held scanner sales slow
    Anon
    2001, Penton Publishing Co. (56):