Toward A Wireless Contact Lens Sensor System with a Micro-Capacitor for Intraocular Pressure Monitoring on in-vitro Porcine Eye

被引:0
|
作者
Yeh, Guan-Ting [1 ]
Wu, Tsung-Wei [1 ]
Tsai, Shang-Wei [1 ]
Hsu, Shun-Hsi [2 ]
Chiou, Jin-Chern [1 ,2 ]
机构
[1] Natl Chiao Tung Univ, Inst Elect & Control Engn, Hsinchu 30010, Taiwan
[2] Natl Chiao Tung Univ, Dept Elect & Comp Engn, Hsinchu 30010, Taiwan
来源
关键词
Contact lens system; Intraocular pressure; Capacitor sensor; Non-invasive Biomedical Monitoring System;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work presents a type of capacitive sensor for intraocular pressure (IOP) measurement on soft contact lens with Radio Frequency Identification (RFID) module. The flexible capacitive IOP sensor and Rx antenna was designed and fabricated using MEMS fabrication technologies that can be embedded on a soft contact lens. The IOP sensing unit is a sandwich structure composed of parylene C as the substrate and the insulating layer, gold as the top and bottom electrodes of the capacitor, and Hydroxyethylmethacrylate (HEMA) as dielectric material between top plate and bottom plate. The main sensing principle is using wireless IOP contact lenses sensor (CLS) system placed on corneal to detect the corneal deformation caused due to the variations of IOP. The variations of intraocular pressure will be transformed into capacitance change and this change will be transmitted to RFID system and recorded as continuous IOP monitoring. The measurement on in-vitro porcine eyes show the pressure reproducibility and a sensitivity of 0.02 pF/4.5 mmHg
引用
收藏
页码:291 / 294
页数:4
相关论文
共 50 条
  • [1] A Contact Lens Sensor System with a Micro-Capacitor for Wireless Intraocular Pressure Monitoring
    Huang, Yu-Chieh
    Yeh, Guan-Ting
    Yang, Tzu-Sen
    Chiou, Jin-Chern
    [J]. 2013 IEEE SENSORS, 2013, : 203 - 206
  • [2] A capacitor-based sensor and a contact lens sensing system for intraocular pressure monitoring
    Chiou, Jin-Chern
    Huang, Yu-Chieh
    Yeh, Guan-Ting
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2016, 26 (01)
  • [3] Wearable contact lens sensor for intraocular pressure monitoring
    Fan, Yanyan
    Tu, Hailing
    Zhao, Hongbin
    Wei, Feng
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2021, 128 : 22 - 22
  • [4] Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
    Leonardi, Matteo
    Pitchon, Elie M.
    Bertsch, Arnaud
    Renaud, Philippe
    Mermoud, Andre
    [J]. ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 433 - 437
  • [5] LC contact lens sensor for ultrasensitive intraocular pressure monitoring
    An, Hongbin
    Wang, Xian
    Liao, Zhikang
    Zhang, Liang
    Zhao, Hui
    Yang, Yingyun
    Song, Jizhou
    Ma, Yinji
    [J]. NPJ FLEXIBLE ELECTRONICS, 2024, 8 (01)
  • [6] Design and Fabricate a Contact Lens Sensor with a Micro-Inductor Embedded for Intraocular Pressure Monitoring
    Tseng, Chien-Kai
    Huang, Yu-Chieh
    Tsai, Shang-Wei
    Yeh, Guan-Ting
    Chang, Chung-Hao
    Chiou, Jin-Chern
    [J]. 2012 IEEE SENSORS PROCEEDINGS, 2012, : 1644 - 1647
  • [7] The Rectenna Design on Contact Lens for Wireless Powering of the Active Intraocular Pressure Monitoring System
    Cheng, H. W.
    Jeng, B. M.
    Chen, C. Y.
    Huang, H. Y.
    Chiou, J. C.
    Luo, C. H.
    [J]. 2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3451 - 3454
  • [8] Design of wireless contact-lens antenna for intraocular pressure monitoring
    Priya, L.
    Vijitha, J.
    Alagappan, M.
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2019, 31 (03) : 315 - 323
  • [9] A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
    Joohee Kim
    Jihun Park
    Young-Geun Park
    Eunkyung Cha
    Minjae Ku
    Hyeon Seok An
    Kyoung-Pil Lee
    Man-Il Huh
    Junmo Kim
    Taek-Soo Kim
    Dai Woo Kim
    Hong Kyun Kim
    Jang-Ung Park
    [J]. Nature Biomedical Engineering, 2021, 5 : 772 - 782
  • [10] A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
    Kim, Joohee
    Park, Jihun
    Park, Young-Geun
    Cha, Eunkyung
    Ku, Minjae
    An, Hyeon Seok
    Lee, Kyoung-Pil
    Huh, Man-Il
    Kim, Junmo
    Kim, Taek-Soo
    Kim, Dai Woo
    Kim, Hong Kyun
    Park, Jang-Ung
    [J]. NATURE BIOMEDICAL ENGINEERING, 2021, 5 (07) : 772 - 782