FT-IR measurement of tagitinin C after solvent extraction from Tithonia diversifolia

被引:10
|
作者
Ziémons, E
Goffin, E
Lejeune, R
Angenot, L
Thunus, L
机构
[1] Univ Liege, Inst Pharm, Bioanalyt & Biopharmaceut Res Ctr, ULg,Lab Analyt Chem,CHU, B-4000 Liege, Belgium
[2] Univ Liege, Inst Pharm, Nat & Synthet Drugs Res Ctr, ULg,CHU,Lab Pharmacognosy, B-4000 Liege, Belgium
关键词
tagitinin C; FT-IR spectroscopy; quantitative determination; Tithonia diversifolia;
D O I
10.1016/j.talanta.2003.08.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tagitinin C, an antiplasmodial compound, identified as one major compound of the subtropical medicinal plant, Tithonia diversifolia, was, determined by FT-IR spectroscopy method. The crude ether extracts from aerial parts of the plant were evaporated to dryness and re-dissolved in tetrachloroethylene (C2Cl4) before analysis. The magnitude of the absorbance of the very specific C=O stretching vibration (v(c=o)) at 1664.8 cm(-1) was exploited in order to quantify tagitinin C. The determination coefficient (r(2)) of the calibration scale was 0.9994, the detection limit was lower than 3 mug ml(-1) and the quantification limit was lower than 10 mug ml(-1). Recovery values from 100.5 to 101.7% were found for spiked concentration levels from 19.91 to 89.95 mug ml(-1). The main characteristics of the curves obtained from the calibration standards and from the standard addition technique were not statistically different (Student t-test) suggesting that matrix effects were negligible. The results obtained for the determination of tagitinin C in the crude ether extract from aerial parts of T diversifolia by LC and FT-IR spectroscopic method agreed well: 0.76 +/- 0.02 and 0.773 +/- 0.009, of tagifinin C in dried plant respectively. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:383 / 387
页数:5
相关论文
共 50 条
  • [21] SOLVENT INFLUENCE ON THE CONFORMATION OF CYCLOSPORINE - AN FT-IR STUDY
    SHAW, RA
    MANTSCH, HH
    CHOWDHRY, BZ
    CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1993, 71 (09): : 1334 - 1339
  • [22] GC FT-IR - A UNIQUE CHOICE FOR SOLVENT ANALYSIS
    KEMPFERT, K
    MIKROCHIMICA ACTA, 1988, 2 (1-6) : 189 - 192
  • [23] SOLVENT ELIMINATION TECHNIQUES FOR MICROBORE HPLC FT-IR
    GRIFFITHS, PR
    FRASER, DJJ
    NORTON, KL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 149 - ANYL
  • [24] Correlation of FT-IR epitaxial thickness measurement
    Kostoulas, Y
    Kneissl, G
    Kohl, I
    SOLID STATE TECHNOLOGY, 2000, 43 (07) : 289 - +
  • [25] Ammonia purification: Performance measurement by FT-IR
    Cook, Joshua T.
    Spieglemano, Jeffry J.
    Alvarez Jr., Daniel
    III-Vs Review, 2002, 15 (03) : 46 - 47
  • [26] FT-IR MEASUREMENT OF MERCAPTOUNDECAHYDRODODECABORATE IN HUMAN PLASMA
    SAINI, P
    LAI, JCK
    LU, DR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (09) : 1091 - 1095
  • [27] Comparison of Ultrasound-assisted Extraction and Dynamic Maceration Over Content of Tagitinin C obtained from Tithonia diversifolia (Hemsl.) A. Gray Leaves Using Factorial Design
    Silva, Aline M. R.
    Ferreira, Nayara L. O.
    Oliveira, Anselmo E.
    Borges, Leonardo L.
    Conceicao, Edemilson C.
    PHARMACOGNOSY MAGAZINE, 2017, 13 (50) : 270 - 274
  • [28] Validation of a FT-IR method for the determination of oils and grease in water using tetrachloroethylene as the extraction solvent
    Farmaki, E.
    Kaloudis, T.
    Dintitrou, K.
    Thanasoulias, N.
    Kousouris, L.
    Tzoumerkas, F.
    DESALINATION, 2007, 210 (1-3) : 52 - 60
  • [29] FT-IR imaging of solvent-induced crystallization in polymers
    Gupper, A
    Chan, KLA
    Kazarian, SG
    MACROMOLECULES, 2004, 37 (17) : 6498 - 6503
  • [30] Measurement of the sensitivity and photometric accuracy of FT-IR spectrometers
    Bowie, BT
    Griffiths, PR
    APPLIED SPECTROSCOPY, 2000, 54 (08) : 1192 - 1202