Seasonal evaluation of outdoor/indoor air quality in primary schools in Lisbon

被引:64
|
作者
Pegas, P. N. [1 ]
Alves, C. A. [1 ]
Evtyugina, M. G. [1 ]
Nunes, T. [1 ]
Cerqueira, M. [1 ]
Franchi, M. [1 ]
Pio, C. A. [1 ]
Almeida, S. M. [2 ]
Cabo Verde, S. [2 ]
Freitas, M. C. [2 ]
机构
[1] Univ Aveiro, Ctr Environm & Marine Studies CESAM, Dept Environm, P-3810193 Aveiro, Portugal
[2] Nucl & Technol Inst, P-2686953 Sacavem, Portugal
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2011年 / 13卷 / 03期
关键词
DIFFERENT INDOOR ENVIRONMENTS; WESTERN-AUSTRALIA; THERMAL COMFORT; HEALTH SYMPTOMS; FUNGI; CHILDREN; VENTILATION; BUILDINGS; EXPOSURE; TURKEY;
D O I
10.1039/c0em00472c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study was to evaluate the indoor (I) and outdoor (O) levels of NO(2), speciated volatile organic compounds (VOCs) and carbonyls at fourteen primary schools in Lisbon (Portugal) during spring, autumn and winter. Three of these schools were also selected to be monitored for comfort parameters, such as temperature and relative humidity, carbon dioxide (CO(2)), carbon monoxide (CO), total VOCs, and both bacterial and fungal colony-forming units per cubic metre. The concentration of CO(2) and bioaerosols greatly exceeded the acceptable maximum values of 1800 mg m(-3) and 500 CFU m(-3), respectively, in all seasons. Most of the assessed VOCs and carbonyls occurred at I/O ratios above unity in all seasons, thus showing the importance of indoor sources and building conditions in indoor air quality. However, it has been observed that higher indoor VOC concentrations occurred more often in the colder months, while carbonyl concentrations were higher in the warm months. In general, the I/O NO(2) ratios ranged between 0.35 and 1, never exceeding the unity. Some actions are suggested to improve the indoor air quality in Lisbon primary schools.
引用
收藏
页码:657 / 667
页数:11
相关论文
共 50 条
  • [41] Comparison of indoor and outdoor concentrations of CO at a public school. Evaluation of an indoor air quality model
    Chaloulakou, A
    Mavroidis, I
    [J]. ATMOSPHERIC ENVIRONMENT, 2002, 36 (11) : 1769 - 1781
  • [42] Indoor and outdoor air contaminants coupling relationship and measures of improving indoor air quality
    Geng, Shibin
    Xiao, Mingxing
    [J]. SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4, 2012, 178-181 : 711 - 717
  • [43] Characterization of indoor air quality using an indoor/outdoor microenvironmental model
    Glytsos, T.
    Smolvk, J.
    Lazaridis, M.
    [J]. RECENT PROGRESS IN COMPUTATIONAL SCIENCES AND ENGINEERING, VOLS 7A AND 7B, 2006, 7A-B : 678 - +
  • [44] Particulate Air Pollution at Schools: Indoor-Outdoor Relationship and Determinants of Indoor Concentrations
    Mohammadyan, Mahmoud
    Alizadeh-Larimi, Ahmad
    Etemadinejad, Siavash
    Latif, Mohd Talib
    Heibati, Behzad
    Yetilmezsoy, Kaan
    Abdul-Wahab, Sabah Ahmed
    Dadvand, Payam
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2017, 17 (03) : 857 - 864
  • [45] Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools
    Andualem, Zewudu
    Gizaw, Zemichael
    Bogale, Laekemariam
    Dagne, Henok
    [J]. MULTIDISCIPLINARY RESPIRATORY MEDICINE, 2019, 14
  • [46] INDOOR AIR QUALITY IN THE SCHOOLS AND STUDENTS PERFORMANCE
    Senitkova, Ingrid
    Bednarova, Petra
    [J]. NANO, BIO AND GREEN - TECHNOLOGIES FOR A SUSTAINABLE FUTURE, VOL II (SGEM 2015), 2015, : 445 - 454
  • [47] Schools Flunk the Test on Indoor Air Quality
    Potera, Carol
    [J]. AMERICAN JOURNAL OF NURSING, 2011, 111 (08) : 19 - 20
  • [48] STUDY ON INDOOR AIR QUALITY IN TUSCAN SCHOOLS
    Benvenuti, A.
    Miligi, L.
    Balocchini, E.
    Aprea, C.
    Bianchimani, V
    Cercena, P.
    Barghini, F.
    Bertuzzi, L.
    Calafiore, V
    Cassinelli, C.
    Cenni, I
    Corsi, F.
    De Lucis, C.
    La Vecchia, R.
    Maurello, M. T.
    Pinto, I
    Sciarra, G.
    Vicentini, M.
    [J]. EPIDEMIOLOGIA & PREVENZIONE, 2010, 34 (5-6): : 135 - 135
  • [49] The Effects of Ventilation on Indoor Air Quality in Schools
    Zhong, Lexuan
    [J]. 2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [50] Management of indoor air quality in Canadian schools
    Rollins, K
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3875 - 3878